The effect of ozone gas with temperatures 35. 40 and 45 Celsius to control on larval and adult stages of Tribolium castaneum was tested and at time of exposure 1.0, 3.0, 7.0, 9.0, 11.0, 13.0 hours and the level of relative humidity prevailing during the test 45 ± 1%. Results showed significant differences between the exposure times, when the percentage of mortality 100% between larvae (primary, intermediate and advanced) in the treatment effect at a temperature of 35 Celsius with ozone gas at exposure time to 9.0, 11.0, 11.0 hours for the three ages respectively, and adult (male and female) in the same treatment when the three heat degrees had given ratios the total mortality reached 100% of both males at exposure time to 7.0 ,3.0, 1.0 hour respectively and females at exposure time 9.0 ,7.0 ,1.0 hour respectively, While completely failed under the effect of a heat treatment at temperatures of 35 Celsius for both stages respectively, while the effect was clear when the temperature is 45 Celsius where the of total mortality of 100% when the heat treatment of the stage of the larval and adult at the time 7.0, 3.1, 1.0 hour respectively. This means that the combined effect of ozone gas with temperatures has resulted in the reduction of the time needed to get the total mortality in both insect stages and significantly influential and that mortality rates in the two stages were increasingly higher degree of exposure used heat and high heat was the lead in reducing the time of exposure and even access to the total mortality.
The weather of Iraq has longer summer season compared with other countries. The ambient temperature during this season reaches over 50 OC which makes the evaporative cooling system suitable for this climate. In present work, the two-stage evaporative cooling system is studied. The first stage is indirect evaporative cooling (IEC) represented by two heat exchangers with the groundwater flow rate (5 L/min). The second stage is direct evaporative cooling (DEC) which represents three pads with groundwater flow rates of (4.5 L/min). The experimental work was conducted in July, August, September, and October in Baghdad. Results showed that overall evaporative efficiency of the system (two coils with three pads each
... Show MoreThe performance of a vapor compression refrigeration system (VCRS)-based residential air conditioner operating in a high-ambient temperature (HAT) country was investigated using six zero-ODP (ozone depletion potential) refrigerants as replacements to R22. The non-flammable alternative refrigerants considered in the present research were R134a, R404A, R407C, R410A, R448A, and R507A. Using the basic conservation laws, the VCRS was modeled during steady-state operation and solved using engineering equation solver (EES) software. Coefficient of performance (COP), pressures and temperatures at compressor suction and discharge, Global Warming Potential (GWP), critical pressure and temperature, compressor
Au XIXe siècle, avec l’excès de la passion, le roman français commence à avoir de nouvelles figures. Il tend à être un reflet de la pensée et de la passion. Stendhal et Balzac révèlent ainsi le conflit de l’âme et donnent à leur héros l’impression que tout est permis.
Ces protagonistes doivent, d’une part, subir des fluctuations psychologiques, et d’autre part, ces héros doivent être capables de faire face aux rancunes et aux conflits destructeurs. Les personnages stendhaliens et balzaciens finissent par croire que leur combat ne portera pas ses fruits, parce que toute passion déséquilibrée mènera, soit à la fol
... Show MoreThis research examines the quantitative analysis to assess the efficiency of the transport network in Sadr City, where the study area suffers from a large traffic movement for the variability of traffic flow and intensity at peak hours as a result of inside traffic and outside of it, especially in the neighborhoods of population with economic concentration. &n
... Show MoreThermal management has become a major issue in the latest high performance computing machines because high CPU temperatures result in inefficient performance and decreased hardware life span. In this work, the cooling performance of a finned metal foam heat sink (FMFHS) was examined. The pore density values of tested copper metal foam (CMF) samples with different values of PPI 5, 10 and 20, with a constant porosity of 90%. For reference, these samples were measured by a conventional Aluminum plate-fin heat sink (CHS). The work was performed under experimental conditions in which air directed over the heat sink surface at air velocities (2.5, 3.0 and 3.5 m/s). The environmental temperature was fixed at 27 °C. Findings
... Show More