Hypertension is one of the leading causes of the global burden of disease, which causes serious health problems. The aim of this study is to investigate the lipid profile levels in sera of Iraqi hypertensive patients by measuring Total cholesterol (TC), triglyceride (TG) and low density lipoproteins (LDL) and kidney function levels by measuring uric acid, urea and creatinine. Seventy five individuals of Iraqi adults (Males) were divided into three groups: 25 hypertensive patients with duration of disease (1-10) year (group 1), 25 hypertensive patients with duration of disease (11-30) year (group 2) and 25 normal individuals as control group (group3). The findings indicate that serum (TC, TG and LDL) levels were significantly elevated (p ? 0.05) compared with healthy group and the values of them were significantly higher in group 2 than in group 1.This study also shows significant positive correlations between TC and TG, LDL (p ?0.01), (p ? 0.05)respectively. From collected data, a significant increase was found in the mean value of serum uric acid, urea and creatinine in hypertensive patients in two groups (1, 2) compared with control group and the levels of them were significantly higher in group2 than in group1 (p?0.01).The results also indicate strong correlations between parameters studied of kidney function tests ( p? 0.01). This study has shown that lipid profile and renal function levels abnormalities are highly prevalent among Iraqi hypertensive patients and also the effect of duration of disease on parameters was studied.
Several authors have used ranking function for solving linear programming problem. In This paper is proposed two ranking function for solving fuzzy linear programming and compare these two approach with trapezoidal fuzzy number .The proposed approach is very easy to understand and it can applicable, also the data were chosen from general company distribution of dairy (Canon company) was proposed test approach and compare; This paper prove that the second proposed approach is better to give the results and satisfy the minimal cost using Q.M. Software
Two well-known fluorescent molecules: fluorescein sodium salt (FSS) and 2,7-dichloro fluorescein (DCF) were tried to prove the efficiency, trustability and repeatability of ISNAG fluorimeter by using discrete and continuous flow injection analysis modes.A linear range of 0.002-1 mmol/L for FSS and 0.003-0.7 mmol/L was for DCF, with LOD 0.0018 mmol/L and 0.002 mmol/L for FSS and DCF respectively, were obtained for discrete mode of analysis. While the continuous mode gave a linear range of 0.002-0.7 mmol/L and 0.003-0.5 mmol/L for FSS and DCF respectively, the LOD were 0.0016mmol/L and 0.0018 mmol/L for FSS and DCF respectively. The results were compared with classical method at variable λex for both fluorescent molecules at 95
... Show MoreThe reaction oisolated and characterized by elemental analysis (C,H,N) , 1H-NMR, mass spectra and Fourier transform (Ft-IR). The reaction of the (L-AZD) with: [VO(II), Cr(III), Mn(II), Co(II), Ni(II), Cu(II), Zn(II), Cd(II) and Hg(II)], has been investigated and was isolated as tri nuclear cluster and characterized by: Ft-IR, U. v- Visible, electrical conductivity, magnetic susceptibilities at 25 Co, atomic absorption and molar ratio. Spectroscopic evidence showed that the binding of metal ions were through azide and carbonyl moieties resulting in a six- coordinating metal ions in [Cr (III), Mn (II), Co (II) and Ni (II)]. The Vo (II), Cu (II), Zn (II), Cd (II) and Hg (II) were coordinated through azide group only forming square pyramidal
... Show MoreThis research work aims to the determination of molybdenum (VI) ion via the formation of peroxy molybdenum compounds which has red-brown colour with absorbance wave length at 455nm for the system of ammonia solution-hydrogen peroxide-molybdenum (VI) using a completely newly developed microphotometer based on the ON-Line measurement. Variation of responses expressed in millivolt. A correlation coefficient of 0.9925 for the range of 2.5-150 ?g.ml-1 with percentage linearity of 98.50%. A detection limit of 0.25 ?g.ml-1 was obtained. All physical and chemical variable were optimized interferences of cation and anion were studied classical method of measurement were done and compared well with newly on-line measurements. Application for the use
... Show More