Preferred Language
Articles
/
bsj-2320
Study the Oxidative Stress, Some Biochemical and Hematological Parameters in patients with agout at AL-Ramadi city
...Show More Authors

This study aims to study the effect of gout disease on complete blood picture and biochemical parameters and some non-enzymatic antioxidants, some tracing elements and lipid peroxidation ,in outpatients with gout disease at Al-Ramadi Teaching-Hospital ,Al-Razi Hospital and the study duration from Octo.2013-to May 2014.(50) blood samples were collected from patients with age groups (30-80 years) from both sexes (28 males,22 females),a (30) blood samples (15 males,15 females) were collected from normal individuals as a control group with age groups (27-75 years). Hematological measurement showed no significant differences in size compressed blood cells, the percentages in ( 45.15 +4.99 and 46.87+6.30) % in patient and control groups respectively, hemoglobin concentrations were ( 14.04+1.66 and 14.30+1.93) g/l in patient and control groups respectively, total number of red blood cells ( 5.21+0.43 and 5.12 +0.58) 106/mm3 in patient and control groups respectively with(P?0.05) in ESR (21.06+13.47 and 13.37 +7.45) mm/hr in patient and control groups respectively with (P?0.05), the total number of WBCs were recorded (8.96+2.04 and 7.50+1.69)in patient and control groups respectively. Results showed also significant differences (P?0.05) in uric acid levels (7.42+0.76 and 5.62+0.88) mg/dl,malondialdehyde levels were recorded (4.45+0.64 and 3.21+0.86) in patient and control groups

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Jan 01 2024
Journal Name
International Journal Of Neutrosophic Science
A New Paradigm for Decision Making under Uncertainty in Signature Forensics Applications based on Neutrosophic Rule Engine
...Show More Authors

One of the most popular and legally recognized behavioral biometrics is the individual's signature, which is used for verification and identification in many different industries, including business, law, and finance. The purpose of the signature verification method is to distinguish genuine from forged signatures, a task complicated by cultural and personal variances. Analysis, comparison, and evaluation of handwriting features are performed in forensic handwriting analysis to establish whether or not the writing was produced by a known writer. In contrast to other languages, Arabic makes use of diacritics, ligatures, and overlaps that are unique to it. Due to the absence of dynamic information in the writing of Arabic signatures,

... Show More
View Publication Preview PDF
Scopus (6)
Scopus Crossref
Publication Date
Wed Nov 13 2019
Journal Name
Al-kindy College Medical Journal
Early Return Of Activity Of Daily Living After Surgery Of Pfna Li Fixation In Elderly Osteoporotic Intertrochanteric
...Show More Authors

Background:    Hip fractures are common, morbid, and costly health events that threaten independence and function of older patients . Early functional recovery is extremely important for elderly patients with femoral intertrochanteric fractures to shorten their hospital stay, omit the necessity of the further nursing and care services, and reduce associated medical expenditures . Assessment of  (ADL) is an important predictor of outcomes Of orthopedic surgery in very early postoperative period at two weeks and a month postoperatively using Japanese orthopedic score get a quick recovery of ADL & return the patient to his or her premorbid level function reducing the morbidity and mortality.

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Aug 25 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Comparative Assessment of In Vitro Effect of Three Fluoride Releasing Agents on Enamel Demineralization around Orthodontic Brackets
...Show More Authors

Background: White spot lesion considered as irreversible tooth demineralization presenting challenge to orthodontists during treatment schedules, fluoride was the most successfully used measure to overcome this challenge. Materials and method: A total of forty sound human permanent premolars were used in the present study and categorized into four groups, in one group the teeth were bonded with stainless steel brackets using Resin-modified glass ionomer cement (RMGIC) and the other three groups the teeth were bonded with light cured composite Resilience® (Ortho technology Co., USA). Group A; Acidulated phosphate fluoride (APF) topical gel (Mfg by DEEPAK PRODUCTS, INC, USA), fluoride ion 1.23% applied on examine area for four minute. Gro

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Sun Jun 01 2025
Journal Name
Al-khwarizmi Engineering Journal
Improving Barcode Vision Scanning Process using a Drone-based Tracking PID Controller for Warehouse in Industry 4.0
...Show More Authors

Drones play a vital role in the fundamental aspects of Industry 4.0 by converting conventional warehouses into intelligent ones, particularly in the realm of barcode scanning. Various potential issues frequently arise during barcode scanning by drones, specifically when the drone camera has difficulty obtaining distinct images due to certain factors, such as distance, capturing the image whilst flying, noise in the environment and different barcode dimensions. In addressing these challenges, this study proposes an approach that combines a proportional–integral–derivative (PID) controller with image processing techniques. The PID controller is responsible for continuously monitoring the camera’s input, detecting the difference

... Show More
View Publication
Crossref
Publication Date
Mon Aug 25 2025
Journal Name
Journal Of Baghdad College Of Dentistry
X-ray diffraction and biocompatibility of glass ionomer cement reinforced by different ratios of synthetic hydroxyapatite
...Show More Authors

Background: This study was done to assist X-ray diffraction and biocompatability of glass ionomer cement reinforced by different ratios of Hydroxyapatite. Materials and Methods: The powder of glass ionomer cement reinforced by different ratios of Hydroxyapatite were used to get X-ray diffraction pattern by X-ray diffraction machine, While for biocompatibility test, A polyethylene tubes containing glass ionomer cement reinforced by different ratios of Hydroxyapatite were implanted on the dorsal submucosal site of Rabbit's tissues and histological slide were prepared for histopathological study. Results: X-ray diffraction test showed that all elements of glass ionomer cement reinforced by different ratios of Hydroxyapatite were react with eac

... Show More
View Publication Preview PDF
Publication Date
Sun Oct 15 2023
Journal Name
Bionatura
Surface assessment of CNC laser treated commercially pure Titanium and Ti 13 Zr 13 Nb alloy
...Show More Authors

This study aimed to evaluate the surface changes of commercial pure Titanium disks (CP Ti) and the Ti 13Nb 13 Zr (Alloy) with a zigzag pattern of laser surface treatment. In vitro, experimental study of CNC Laser treatment on the CP Ti and Alloy disks. Texturing the surfaces of CP Ti and Alloy disks via CNC laser, the sample disks were analyzed using surface roughness, wettability and FESEM. The FESEM revealed a proper increase in the surface texturing and roughness on macro and micro measures without crack formation or dramatic change of the core substance of the CP Ti and Alloy disks. The CNC laser is an effective and suitable method for surface texturing CP Ti and Alloy for dental implantology. Keywords: Commercial pure Titanium;

... Show More
View Publication Preview PDF
Crossref (1)
Scopus Crossref
Publication Date
Tue Dec 01 2020
Journal Name
Journal Of Engineering
Simulation and Experimental Walking Pattern Generation for Two Types of Degrees of Freedom Bipedal Locomotion Robot
...Show More Authors

Humanoids or bipedal robots are other kinds of robots that have legs. The balance of humanoids is the general problem in these types when the other in the support phase and the leg in the swing phase. In this work, the walking pattern generation is studied by MATLAB for two types of degrees of freedom, 10 and 17 degrees of freedom. Besides, the KHR-2HV simulation model is used to simulate the experimental results by Webots. Similarly, Arduino and LOBOT LSC microcontrollers are used to program the bipedal robot. After the several methods for programming the bipedal robot by Arduino microcontroller, LOBOT LSC-32 driver model is the better than PCA 96685 Driver-16 channel servo driver for programming the bipedal walking rob

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Aug 18 2010
Journal Name
Journal Of Kerbala University
Synthesis of New Type of Sugar Ligands Starting from D-Glucose And Screening Their Biological Activity
...Show More Authors

Publication Date
Wed Feb 29 2012
Journal Name
Al-khwarizmi Engineering Journal
Effect of Fuel Cetane Number on Multi-Cylinders Direct Injection Diesel Engine Performance and Exhaust Emissions
...Show More Authors

Due to the energy crisis and the stringent environmental regulations, diesel engines are offering good hope for automotive vehicles. However, a lot of work is needed to reduce the diesel exhaust emissions and give the way for full utilization of the diesel fuel’s excellent characteristics.

A kind of cetane number improver has been proposed and tested to be used with diesel fuel as                 ameans of reducing exhaust emissions. The addition of (2-ethylhexyl nitrate) was designed to raise fuel cetane number to three stages, 50, 52 and 55 compared to the used conventional diesel fuel whose CN was 48.5. The addition of CN improver results in the decre

... Show More
View Publication Preview PDF
Publication Date
Thu Oct 01 2020
Journal Name
Iraqi Journal Of Applied Physics
Spectral and Electrical Characteristics of Nanostructured NiO/TiO 2 Heterojunction Fabricated by DC Reactive Magnetron Sputtering
...Show More Authors

In this work, p-n junctions were fabricated from highly-pure nanostructured NiO and TiO2 thin films deposited on glass substrates by dc reactive magnetron sputtering technique. The structural characterization showed that the prepared multilayer NiO/TiO2 thin film structures were highly pure as no traces for other compounds than NiO and TiO2 were observed. It was found that the absorption of NiO-on-TiO2 structure is higher than that of the TiO2-on-NiO. Also, the NiO/TiO2 heterojunctions exhibit typical electrical characteristics, higher ideality factor and better spectral responsivity when compared to those fabricated from the same materials by the same technique and with larger particle size and lower structural purity.

View Publication Preview PDF