With the development of communication technologies for mobile devices and electronic communications, and went to the world of e-government, e-commerce and e-banking. It became necessary to control these activities from exposure to intrusion or misuse and to provide protection to them, so it's important to design powerful and efficient systems-do-this-purpose. It this paper it has been used several varieties of algorithm selection passive immune algorithm selection passive with real values, algorithm selection with passive detectors with a radius fixed, algorithm selection with passive detectors, variable- sized intrusion detection network type misuse where the algorithm generates a set of detectors to distinguish the self-samples. Practical Experiments showed the process to achieve a high rate of detection in the system designer using data NSL-KDD with 12 field without vulnerability to change the radius of the detector or change the number of reagents were obtained as the ratio between detection (0.984, 0.998, 0.999) and the ratio between a false alarm (0.003, 0.002, 0.001). Contrary to the results of experiments conducted on data NSL-KDD with 41 field contact, which affected the rate of detection by changing the radius and the number of the detector as it has been to get the proportion of uncovered between (0.44, 0.824, 0.992) and the percentage of false alarm between (0.5, 0.175, 0.003).
In this paper, the theoretical cross section in pre-equilibrium nuclear reaction has been studied for the reaction at energy 22.4 MeV. Ericson’s formula of partial level density PLD and their corrections (William’s correction and spin correction) have been substituted in the theoretical cross section and compared with the experimental data for nucleus. It has been found that the theoretical cross section with one-component PLD from Ericson’s formula when doesn’t agree with the experimental value and when . There is little agreement only at the high value of energy range with the experimental cross section. The theoretical cross section that depends on the one-component William's formula and on-component corrected to spi
... Show MoreAbstract
Purpose: The research attempts to Stand on the reality of the effective application of of strategic information systems in telecommunications companies in the Kurdistan Region, and what is the amount of the impact of such systems on promoting of Strategic Intelligence.
Design/Methodology/Approach: The Applied method has been used, In order to achieve the objectives of the research has been the development of a questionnaire prepared for this purpose and then distributed to (11) Company of Iraqi communications operating in Kurdistan Region companies, it has been used questionnaire to collect data in order to develop
... Show MoreObjective. Infection with Coxsackie virus. This virus that damages pancreatic cells, has long been linked to the onset of insulin-dependent diabetic mellitus (IDDM). Pro-inflammatory cytokines can be produced as a result of this illness. Tumor necrosis factor-a is one of these pro-inflammatory cytokines. Materials and Methods. Blood sample were collected from 180 Iraqi participants. Ninety of them is type 1 diabetic patients and other 90 is healthy control .both groups were tested for the incidence of Coxsackie virus B IgG. So the patients groups is divided to two groups according to sero positivity of CVB-IgG .all 180 patients tested to measure of level of TNF-α. Results. The Results showed increasing in levels of TNF-α in CBV po
... Show MoreIraq suffers from serious pollution with harmful particles that have important direct and indirect effects on human activities and human health. In this research, a system for detecting pollutants in the air was designed and manufactured using infrared laser technology. This system was used to detect the presence of pollutants in the dust storms that swept the city of Baghdad which could have a negative impact on human health and living organisms.
The designed detection system based on the use of infrared laser (IR) with a wavelength of 1064 nm was used for the purposes of detecting pollutants based on the scattering of the laser beam from these pollutants. The system was aligned to obtain the best signal for the scattered rays, w
... Show MoreThis paper deals with an analytical study of the flow of an incompressible generalized Burgers’ fluid (GBF) in an annular pipe. We discussed in this problem the flow induced by an impulsive pressure gradient and compare the results with flow due to a constant pressure gradient. Analytic solutions for velocity is earned by using discrete Laplace transform (DLT) of the sequential fractional derivatives (FD) and finite Hankel transform (FHT). The influences of different parameters are analyzed on a velocity distribution characteristics and a comparison between two cases is also presented, and discussed in details. Eventually, the figures are plotted to exhibit these effects.
The lethality of inorganic arsenic (As) and the threat it poses have made the development of efficient As detection systems a vital necessity. This research work demonstrates a sensing layer made of hydrous ferric oxide (Fe2H2O4) to detect As(III) and As(V) ions in a surface plasmon resonance system. The sensor conceptualizes on the strength of Fe2H2O4 to absorb As ions and the interaction of plasmon resonance towards the changes occurring on the sensing layer. Detection sensitivity values for As(III) and As(V) were 1.083 °·ppb−1 and 0.922 °·ppb
CdO films were deposited on substrates from glass, Silicon and Porous silicon by thermal chemical spray pyrolysis technique with different thicknesses (130 and 438.46) nm. Measurements of X-ray diffraction of CdO thin film proved that the structure of the Polycrystalline is cubic lattice, and its crystallite size is located within nano scale range where the perfect orientation is (200). The results show that the surface’s roughness and the root mean square increased with increasing the thickness of prepared films. The UV-Visible measurements show that the CdO films with different thicknesses possess an allowed direct transition with band gap (4) eV. AFM measurement revealed that the silicon porosity located in nano range. Cadmium oxide f
... Show More