The molluscum contagiosum virus (MCV) is a dermatotropic poxvirus. The causative agent of molluscum contagiosum (MC) is nonlethal, common and worldwide. Additionally, little inflammation is associated with MC papules. The present study aims to evaluate the immune status of MC patients by measuring the level of immunoglobulins IgG and IgM by using the radial immune diffusion assay (RIA) and the level of interleukin 18 receptor 1 (IL-18R1) by the Enzyme-linked immunosorbent assay (ELISA).The study is conducted during November 2013 to April, 2014 in outpatient clinic of Baquba Teaching Hospital. There are 75 patients, diagnosed with clinical lesions of MCV on different areas of the body, whose age is ranged between 2-50 years including 40(53.3%) males and 35(46.7%) females. The study includes 15 healthy persons age between 2-50 years. The level of IL 18R1 were significantly elevated in patients (677.15±874.22) compared with control (178.46±31.79 ng/ml). There is also a significant elevation in the mean level of serum IgM, where it is 1946.6±825.6 mg/dl while in control group is 140.1±68.7mg/dl. By contrast in patients with lower levels of IgG than the control, the mean serum IgG level in patient is 221.9±96.7 mg/dl while in the control is 1229.9±299.7 mg/dl. Finally, there is no significant difference between MC patients from rural area and urban area.
Abstract: This study aims to investigate the backscattering electron coefficient for SixGe1-x/Si heterostructure sample as a function of primary electron beam energy (0.25-20 keV) and Ge concentration in the alloy. The results obtained have several characteristics that are as follows: the first one is that the intensity of the backscattered signal above the alloy is mainly related to the average atomic number of the SixGe1-x alloy. The second feature is that the backscattering electron coefficient line scan shows a constant value above each layer at low primary electron energies below 5 keV. However, at 5 keV and above, a peak and a dip appeared on the line scan above Si-Ge alloy and Si, respectively, close to the interfacing line
... Show MoreThe synthesis of ligands with N2S2 donor sets that include imine, an amide, thioether, thiolate moieties and their metal complexes were achieved. The new Schiff-base ligands; N-(2-((2,4-diphenyl-3-azabicyclo[3.3.1]nonan-9-ylidene)amino)ethyl)-2-((2-mercaptoethyl)thio)-acetamide (H2L1) and N-(2-((2,4-di-p-tolyl-3-azabicyclo[3.3.1]nonan-9-ylidene)amino)ethyl)-2-((2-mercaptoethyl)thio) acetamide (H2L2) were obtained from the reaction of amine precursors with 1,4-dithian-2-one in the presence of triethylamine as a base in the CHCl3 medium. Complexes of the general formula K2<
Six transition metal complexes of Cr (III), Mn(II), Co(II), Ni(II), Cu(II), and Zn(II) were prepared using 1,2-bis -(4-Amino-2,3-dimethyl-1- phenyl-pyrazolinyl)-diimino ethane(L) as ligand. These complexes were characterized by elemental analysis, magnetic susceptibility, UV/VIS and FT-IR spectroscopy. These data showed that the solid complexes of Mn(II), Co(II), Zn(II) were tetrahedral geometry, and Cr(III) was octahedral while the symmetry around Ni(II) and Cu(II) ions with the new ligand were square planar of the formula [ML]Cl2 , M=Ni(II) and Cu(II).
A simple method for the determina
... Show MoreRetainers have the potential to detrimentally impact periodontal health and contribute to tooth decay.
To investigate periodontal health and bacterial biofilm related to Poly-Ether-Ether-Ketone (PEEK) fixed retainers as compared to Dead-soft coaxial fixed retainer (DSC).
A two-arm parallel groups single-centre randomized c
Background: Change in palatal vault shape and Reinforcement of high impact acrylic denture base resin may in turn affect the dimensional accuracy of acrylic resin and affecting the fitness of the denture.This study evaluated tostudy the effect of fiber reinforcement for high-impact acrylic resin denture base with different palatal vault shapes on adaptation or gap space between the denture base and the stone cast and compare with non-fiber reinforcement and effect of palatal vault shapes on adaptation of non-reinforced and fiber reinforced high impact denture base acrylic resin Material and method: Three different palatal vault shapes were prepared on standard casts using CNC (computer numerical control) machine. 60 samples of heat polymeri
... Show More