The molluscum contagiosum virus (MCV) is a dermatotropic poxvirus. The causative agent of molluscum contagiosum (MC) is nonlethal, common and worldwide. Additionally, little inflammation is associated with MC papules. The present study aims to evaluate the immune status of MC patients by measuring the level of immunoglobulins IgG and IgM by using the radial immune diffusion assay (RIA) and the level of interleukin 18 receptor 1 (IL-18R1) by the Enzyme-linked immunosorbent assay (ELISA).The study is conducted during November 2013 to April, 2014 in outpatient clinic of Baquba Teaching Hospital. There are 75 patients, diagnosed with clinical lesions of MCV on different areas of the body, whose age is ranged between 2-50 years including 40(53.3%) males and 35(46.7%) females. The study includes 15 healthy persons age between 2-50 years. The level of IL 18R1 were significantly elevated in patients (677.15±874.22) compared with control (178.46±31.79 ng/ml). There is also a significant elevation in the mean level of serum IgM, where it is 1946.6±825.6 mg/dl while in control group is 140.1±68.7mg/dl. By contrast in patients with lower levels of IgG than the control, the mean serum IgG level in patient is 221.9±96.7 mg/dl while in the control is 1229.9±299.7 mg/dl. Finally, there is no significant difference between MC patients from rural area and urban area.
The widespread use of the Internet of things (IoT) in different aspects of an individual’s life like banking, wireless intelligent devices and smartphones has led to new security and performance challenges under restricted resources. The Elliptic Curve Digital Signature Algorithm (ECDSA) is the most suitable choice for the environments due to the smaller size of the encryption key and changeable security related parameters. However, major performance metrics such as area, power, latency and throughput are still customisable and based on the design requirements of the device.
The present paper puts forward an enhancement for the throughput performance metric by p
... Show Moresix specimens of the Hg0.5Pb0.5Ba2Ca2Cu3-y
In current article an easy and selective method is proposed for spectrophotometric estimation of metoclopramide (MCP) in pharmaceutical preparations using cloud point extraction (CPE) procedure. The method involved reaction between MCP with 1-Naphthol in alkali conditions using Triton X-114 to form a stable dark purple dye. The Beer’s law limit in the range 0.34-9 μg mL-1 of MCP with r =0.9959 (n=3) after optimization. The relative standard deviation (RSD) and percentage recoveries were 0.89 %, and (96.99–104.11%) respectively. As well, using surfactant cloud point extraction as a method to extract MCP was reinforced the extinction coefficient(ε) to 1.7333×105L/mol.cm in surfactant-rich phase. The small volume of organi
... Show MoreIn this manuscript, the effect of substituting strontium with barium on the structural properties of Tl0.8Ni0.2Sr2-xBrxCa2Cu3O9-δcompound with x= 0, 0.2, 0.4, have been studied. Samples were prepared using solid state reaction technique, suitable oxides alternatives of Pb2O3, CaO, BaO and CuO with 99.99% purity as raw materials and then mixed. They were prepared in the form of discs with a diameter of 1.5 cm and a thickness of (0.2-0.3) cm under pressures 7 tons / cm2, and the samples were sintered at a constant temperature o
... Show MoreFor aspirin estimated, a molecularly imprinted polymer MIP-ASP electrodes were generated by electro-polymerization process, the electrodes were prepared by combining the template (aspirin) with (vinyl acetate (VA), 1-vinylimidizole (VIZ) as a functional monomer and N, N-methylene bisacrylamide (MBAA) as crosslinkers using benzoyl peroxide (BPO) as an initiator. The efficiency of the membrane electrodes was analyzed by differential pulse voltammetry (DPV). Four electrodes were synthesized using two different plasticizers, di-butyl sebacate (DBS), di-octyl phthalate (DOP) in PVC matrix. Scanning electron microscopy (SEM) was used to describe the generated MIP, studying the electrodes properties, the slope, detection limit, and life
... Show More