Preferred Language
Articles
/
bsj-2135
Microbial Contamination of Infant Milk Formula in Local Markets
...Show More Authors

This study is conducted to identify the microbial content of some types of infant milk formula available in the local markets of the city of Baghdad and their conformity microbial limits sited by the Iraqi standard. Seventy samples were collected from trademarks of imported infant milk formula included of five samples of infant milk formula No (1) and five samples of follow-up formula No (2). These samples were collected randomly from shops in the local markets of Baghdad city on both sides of Karkh and Rusafa included the following kinds: Dialac 1, Dialac 2 ,Celia 1, Celia 2 ,Biomil 1, Biomil 2 , Nactalia 1, Nactalia 2, Novalac 1 , Novalac 2 , Similac 1 , imilac 2 , Guigos 1, Guigos 2. Some microbial tests were done which included estimating the number of Total Plate Count bacteria, Coliform bacteria, Salmonella bacteria, Staphylococcus bacteria and Molds,Yeasts . The results show there is no any type of Coliform and Salmonella bacteria in infant milk; While high number of total plate count bacteria, Staphylococcus bacteria,Yeasts and Molds are showed in all kinds of formula, therefore do not exceed the microbiological limits of Iraqi standards(IQS) for good quality infant milk powder, with except the trademark Dialac1, Dialac 2 .

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Oct 01 2018
Journal Name
Iraqi Journal Of Physics
Analysis of the absorption spectra in the visible and ultraviolet regions of some medical ointments available in Iraqi markets
...Show More Authors

Three types of medical commercial creams Silvazine, Cinolon Tar and Hydroquinon Domina were incorporated in this study. The medical creams were taken directly and placed uniformly on the glass slide. Each type of pharmaceutical was weighed at 1 mg and dispersed on an area of 1x1 cm. This process ensures same thickness for all samples. The creams were analyzed by using double-beam UV/visible spectrophotometer Metertech SP8001. The absorption spectrum for each of samples was measured against wavelength range of 300–700 nm.

View Publication Preview PDF
Crossref
Publication Date
Tue Aug 01 2023
Journal Name
Baghdad Science Journal
The Ecological Risk Assessment of Mercury Contamination in a Mangrove Ecosystem of the Segara Anakan Cilacap, Indonesia
...Show More Authors

Ecological risk assessment of mercury contaminant has a means to analyze the ecological risk aspect of ecosystem using the potential impact of mercury pollution in soil, water and organism. The ecological risk assessment in a coastal area can be shown by mangrove zonation, clustering and interpolation of mercury accumulation. This research aims to analyze ecological risk assessment of potential mercury (including bioaccumulation and translocation) using indicators of species distribution, clustering, zonation and interpolation of mercury accumulation. The results showed that the Segara Anakan had a high risk of mercury pollution, using indicators like as the potential of mercury contaminant in water body was 0137±0.0137 ppm, substrate a

... Show More
View Publication Preview PDF
Scopus (3)
Scopus Crossref
Publication Date
Fri Jun 30 2023
Journal Name
Anbar Journal Of Agricultural Sciences
MICROBIAL FERTILIZERS EXISTENCE AND ITS RELATIONSHIP TO HEAVY METALS IN SOME SUSTAINABLE AGRICULTURAL FIELDS IN ANBAR GOVERNORATE
...Show More Authors

Investigations made and soil samples brought from 14 sites in different areas, including Abu Ghraib and Al Anbar. Tests and measurements made in the Microbiology Laboratory at the College of Agriculture, University of Anbar. Department of Soil Sciences and water Resources, in order to isolate bio-fertilizers and test isolates fixing nitrogen in atmosphere and solvents for phosphorous compounds efficiency. The experiment included isolating and diagnosis of bacteria from rhizosphere soils of different plants that were brought from different agricultural areas, 74 isolates obtained by soils alleviation, and then the bio-chemical morphological and microscopic characteristics of these soils studied. The results showed that the most abundant and

... Show More
View Publication
Scopus (9)
Crossref (3)
Scopus Crossref
Publication Date
Mon Sep 04 2017
Journal Name
Journal Of Chemical And Pharmaceutical Research
Lead, Cadmium and Nickel contamination of roadside soils and plant leaves in Baghdad City
...Show More Authors

Publication Date
Mon Jan 01 2018
Journal Name
International Journal Of Science And Research
Comparison of Bacterial Contamination between I Phone and Galaxy Devices
...Show More Authors

Ninety eight mobile samples, (54) galaxy phone and (44) I phone, were swabbed for bacterial culture determination by culturing on MacConky agar , Blood agar , Mannitol salt agar , Muller Hinton agar .Staphylococcuswas the highest frequent isolated bacteria from Galaxy phone (33%) and I phone (37%). This study revealed that galaxy phone appears less contaminated with bacteria, the ratio of non-contaminated devices is (44%) when compared with I phone (9%). Sensitivity test showed that Ogmintin have the lowest effect on Staphylococcusisolated from both type of devices while cefitriaxone have the highest effect. DNA of isolate from galaxy 31 that exhibit highest resistance against antibiotics was extracted and 16S rRNA gene was polymerized by P

... Show More
Preview PDF
Publication Date
Thu Nov 19 2020
Journal Name
Veterinary Medicine International
Isolation and Molecular Identification and Antimicrobial Susceptibility of Providencia spp. from Raw Cow’s Milk in Baghdad, Iraq
...Show More Authors

A total of sixty raw milk samples were collected from (street vendors and shops) from Baghdad city, Iraq. The samples were inoculated into peptone water and, then, subcultured onto MacConkey agar and Blood agar. Identification of isolates was confirmed by microscopic examination, cultural characteristic, biochemical tests, Vitek (VITEK®2 system), and Biolog GN substrate reactions followed by 16S rRNA and specific genes sequencing. Of 60 raw cow’s milk samples, Providencia spp. were identified only in 4 samples (6.67%) and P. rettgeri was the most common, 2/4 (50%), followed by P. stuartii and P. vermicola, 1/4 (25%). Antimicrobial susceptibility tests were conducted against ten antibiotics by the disc diffusion method. All Provid

... Show More
View Publication
Scopus (6)
Crossref (5)
Scopus Crossref
Publication Date
Thu Jun 01 2017
Journal Name
Process Biochemistry
Microbial levan from Brachybacterium phenoliresistens : Characterization and enhancement of production
...Show More Authors

View Publication
Scopus (46)
Crossref (42)
Scopus Clarivate Crossref
Publication Date
Wed Mar 10 2021
Journal Name
Baghdad Science Journal
Study for evidence of bacteria contamination in the southern part of the Diyala River / Iraq
...Show More Authors

Were studied some bacteria evidence of pollution as well as the total number of live bacteria in the waters of the Diyala river and selected five stations within the 17 km final Diyala River before its mouth in the Tigris River was the first before the new bridge of the Diyala River about 4 km and the second after the mouth of the water purification plant Rustumiya suit inverselywith temperatures

View Publication Preview PDF
Publication Date
Tue May 01 2018
Journal Name
Journal Of Physics: Conference Series
Estimation of Heavy Metals Contamination in the Soil of Zaafaraniya City Using the Neural Network
...Show More Authors

View Publication
Scopus (4)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Mon Mar 08 2021
Journal Name
Baghdad Science Journal
Analytical Potentiality of Computer - Controlled Background Correction with Electrothermal Atomic Emission Spectrometry : Determination of Copper in Milk Powder
...Show More Authors

A fully automatic electrothermal atomic emission spectrometry (ETA-AES) is described. This system is based on an echelle monochromator modified for wave¬length modulation which is completely controlled by microcomputer . The advantages of the system in atomic spectrometry have been discussed . Aspects of the analytical performances such as calibration ? dection limit, precision , and recovery for copper are considered . This system is applied for routine determination of copper in commercial powdered mill? by slurr>' atomization versus aqueous atomization techniques.

View Publication Preview PDF