Preferred Language
Articles
/
bsj-2074
Flow Injection Spectrophotometric Determination of Thymol using 4-Aminoantipyrine and Copper(II) Nitrate
...Show More Authors

Flow-injection (FI) spectrophotometric method has been developed for the analysis of thymol in pharmaceutical preparations. The method is based on organic coupling reaction between thymol and 4-amino antipyrine in the presence of alkaline medium to form an intense stable red color complex with copper nitrate that has a maximum absorption at 490 nm. Optimum conditions for determination of the drug was investigated .The calibration graph was linear over the range of 5-500 µg.ml-1 of thymol . The limit of detection (LOD) and limit of quantification (LOQ) were 1.81 ?g mL-1 and 3.60 ?g mL-1 respectively .The proposed method was applied satisfactorily to the determination of thymol in mouth wash preparations. The procedure is characterized by its simplicity, accuracy and precision.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Jul 02 2016
Journal Name
Bioremediation Journal
Kinetic, thermodynamic, and equilibrium biosorption of Pb(II), Cu(II), and Ni(II) using dead mushroom biomass under batch experiment
...Show More Authors

In this study, a low-cost biosorbent, dead mushroom biomass (DMB) granules, was used for investigating the optimum conditions of Pb(II), Cu(II), and Ni(II) biosorption from aqueous solutions. Various physicochemical parameters, such as initial metal ion concentration, equilibrium time, pH value, agitation speed, particles diameter, and adsorbent dosage, were studied. Five mathematical models describing the biosorption equilibrium and isotherm constants were tested to find the maximum uptake capacities: Langmuir, Freundlich, Redlich-Peterson, Sips, and Khan models. The best fit to the Pb(II) and Ni(II) biosorption results was obtained by Langmuir model with maximum uptake capacities of 44.67 and 29.17 mg/g for these two ions, respectively, w

... Show More
Crossref (5)
Crossref
Publication Date
Fri Sep 30 2016
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Sorption of Nitrate Salts from Wastewater without and with Modification Orange Peel
...Show More Authors

This investigation deals with the use of orange peel (OP) waste as adsorbent for removal of nitrate (NO3) from simulated wastewater. Orange peel prepared in two conditions dried at 60C° (OPD) and burning at 500 °C (OPB). The effect of pH: 2-10, contact time: 30- 180 min, sorbent weight: 0.5- 3.0 g were considered. The optimal pH value for NO3 adsorption was found to be 2.0 for both adsorbents. The equilibrium data were analyzed using Langmuir and  Freundlich isotherm models. Freundlich model was found to fit the equilibrium data very well with high-correlation coefficient (R2). The adsorption kinetics was found to follow pseudo-second-order rate kinetic model, with a good correlation (R2

... Show More
View Publication Preview PDF
Publication Date
Tue Jun 05 2018
Journal Name
Journal Of Molecular Structure
Synthesis, characterization, experimental and theoretical structure of novel Dichloro(bis{2-[1-(4-methoxyphenyl)-1H-1,2,3-triazol-4-ylkN3] pyridine-kN})metal(II) compounds, metal ΒΌ Mn, Co and Ni
...Show More Authors

The syntheses, characterizations and structures of three novel dichloro(bis{2-[1-(4-methoxyphenyl)-1H-1,2,3-triazol-4-yl-κN3]pyridine-κN})metal(II), [M(L)2Cl2], complexes (metal = Mn, Co and Ni) are presented. In the solid state the molecules are arranged in infinite hydrogen-bonded 3D supramolecular structures, further stabilized by weak intermolecular π…π interactions. The DFT results for all the different spin states and isomers of dichloro(bis{2-[1-phenyl-1H-1,2,3-triazol-4-yl-κN3]pyridine-κN})metal(II) complexes, [M(L1)2Cl2], support experimental measurements, namely that (i) d5 [Mn(L1)2Cl2] is high spin with S = 5/2; (ii) d7 [Co(L1)2Cl2] has a spin state of S = 3/2, (iii) d8 [Ni(L1)2Cl2] has a spin state of S =

... Show More
Preview PDF
Publication Date
Fri Feb 14 2014
Journal Name
Desalination And Water Treatment
Copper biosorption using local Iraqi natural agents
...Show More Authors

Industrial effluents loaded with heavy metals are a cause of hazards to the humans and other forms of life. Conventional approaches, such as electroplating, ion exchange, and membrane processes, are used for removal of copper, cadmium, and lead and are often cost prohibitive with low efficiency at low metal ion concentration. Biosorption can be considered as an option which has been proven as more efficient and economical for removing the mentioned metal ions. Biosorbents used are fungi, yeasts, oil palm shells, coir pith carbon, peanut husks, and olive pulp. Recently, low cost and natural products have also been researched as biosorbent. This paper presents an attempt of the potential use of Iraqi date pits and Al-Khriet (i.e. substances l

... Show More
Crossref (6)
Crossref
Publication Date
Sun Jun 11 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Spectrophotometric Determination of Tetracycline Hydrochloride in Pure Form and Pharmaceutical Preparation by Coupling with Diazotized Anthranilic Acid
...Show More Authors

  A simple, fast and sensitive spectrophotometric method has been applied for the determination of tetracycline hydrochloride in its pure form and in pharmaceutical preparations. The method based on coupling reaction of the antibiotic with diazotized anthranilic acid to form a stable yellow azo dye which shows a maximum absorption at 419 nm. Uni- and multivariate approaches were followed in optimizing the experimental conditions. Under optimum experimental conditions obtained via multivariate (Central Composite Design), the linearity of the constructed calibration curve was in the range of 0.560 μg.mL-1 with molar absorptivity of 14619 L.mol-1.cm-1 and the value of detection limit was 0.2813μg.mL-1. The capability of the metho

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sun Dec 07 2008
Journal Name
Baghdad Science Journal
Spectrophotometric micro determination of drug promethazine hydrochloride in some pharmaceutical by chelating with Rhodium
...Show More Authors

The drug promethazine hydrochloride (PRZH) forms with rhodium (II) a colored chelate (?max = 472 nm) complex at (pH = 2.1) which is extractable with benzyl alcohol as organic solvent. Under the appropriate experimental conditions a calibration plot was set up from which some analytical parameter were derived and deduced by regression. Standard addition procedure was also adopted. It has been estimated that the concentration of the drug PRZH to be 24.89 mg per unit and 24.19 mg per unit for both calibrations. Under optimal conditions, the developed method has been achieved the following characteristics: LDR (30 – 150 µg ml-1 ) PRZH , RSD % ( 0.6 – 2.47 ) , sandell sensitivity( 0.0844 µg. cm -2 ) , LOD ( 1.66 µgml-1 ) , recovery

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Fri Nov 24 2023
Journal Name
Iraqi Journal Of Science
New Approach for the On-Line Spectrophotometric Determination of Folic Acid in Pure and Pharmaceutical Preparation via Oxidation by Cerium(IV) Sulphate Using Ayah 3Sx3-3D-Solar Cell CFI Spectrophotometer Analyzer
...Show More Authors

A newly photometric analytical method characterized by its speed and sensitivity was developed for the determination of folic acid in pure and pharmaceutical samples via its oxidation to reddish-orange coloured complex through oxidation by cerium (IV) sulphate in aqua medium using homemade Ayah 3Sx3-3D-solar cell CFI photometer. The colored species were determined using supper bright green light emitting diode (LED) as a source. A 100μl was taken as a best sample volume for the determination of folic acid. The linearity of calibration curve for the instrument response versus folic acid concentration was 0.005-20 mmol.L-1 while the L.O.D. was 0.5  mol.L-1 from the stepwise dilution for the minimum concentration of lowest concentration

... Show More
View Publication Preview PDF
Publication Date
Tue Oct 01 2019
Journal Name
International Journal Of Drug Delivery Technology
Simple and Rapid Method For Estimate of Propranolol With Bi (III) Via Long-Distance Chasing Photometer (NAG-ADF-300-2) Utilization Continuous Flow Injection Analysis
...Show More Authors

A simple, sensitive and rapid method was used for the estimate of: Propranolol with Bi (III) to prove the efficiency, reliability and repeatability of the long distance chasing photometer (NAG-ADF-300-2) using continuous flow injection analysis. The method is based on a reaction between propranolol and Bi (III) in an aqueous medium to obtain a yellow precipitate. Optimum parameters were studied to increase the sensitivity for the developed method. A linear range for calibration graph was 0.1-25 mmol/L for cell A and 1-40 mmol/L for cell B, and LOD 51.8698 ng/200 µL and 363.0886 ng /200 µL , respectively to cell A and cell B with correlation coefficient (r) 0.9975 for cell A, 0.9966 for cell B, RSD% was lower than 1%, (n = 8) for the

... Show More
Publication Date
Sun Sep 01 2019
Journal Name
Journal Of Global Pharma Technology
Spectrophotometric determination of loratadine in syrup and study viscosity conductivity and thermodynamic of binary mixed systems of surfactants with loratadine"
...Show More Authors

Scopus
Publication Date
Mon Oct 01 2018
Journal Name
Journal Of Engineering
Fabrication of Copper-Graphite MMCs Using Powder Metallurgy Technique
...Show More Authors

Copper, and its, alloys and composites (being the matrix), are broadly used in the electronic as well as bearing materials due to the excellent thermal and electrical conductivities it has.

In this study, powder metallurgy technique was used for the production of copper graphite composite with three volume perc ent of graphite.  Processing parameters selected is (900) °C sintering temperature and (90) minutes holding time for samples that were heated in an inert atmosphere (argon gas). Wear test results showed a pronounced improvement in wear resistance as the percent of graphite increased which acts as solid lubricant (where wear rate was decreased by about 88% as compared with pure Cu). Microhardness and

... Show More
View Publication Preview PDF
Crossref (5)
Crossref