Preferred Language
Articles
/
bsj-2072
Spectrophotometric Determination of Paracetamol in bulk and Pharmaceutical Preparations
...Show More Authors

A simple, and rapid spectrophotometric method for the estimation of paracetamol has been developed. The methods is based on diazotisation of 2,4-dichloroaniline followed by a coupling reaction with paracetamol in sodium hydroxide medium. All variables affecting the reaction conditions were carefully studied. Beer's law is obeyed in the concentration range of 4-350 ?gml?1 at 490 nm .The method is successfully employed for the determination of paracetamol in pharmaceutical preparations. No interferes observed in the proposed method. Analytical parameters such as accuracy and precision have been established for the method and evaluated statistically to assess the application of the method.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Mar 31 2017
Journal Name
Al-khwarizmi Engineering Journal
Design and Implementation of a Pharmaceutical Inventory Database Management System
...Show More Authors

The main aim of this paper are the design and implementation of a pharmaceutical inventory database management system. The system was implemented by creating a database containing information about the stored medicines in the inventory, customers making transactions with the pharmaceutical trading company (which owns the inventory), medical suppliers, employees, payments, etc. The database was connected to the main application using C sharp. The proposed system should help in manag inginventory operations which include adding/updating employees’ information, preparing sale and purchase invoices, generating reports, adding/updating customers and suppliers, tracking customer payments and checking expired medicines in order to be disposed

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Jun 30 2020
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Process Optimization Study of Pb(II) Removal by Bulk Liquid Membrane (BLM)
...Show More Authors

   Box-Wilson experimental design method was employed to optimized lead ions removal efficiency by bulk liquid membrane (BLM) method. The optimization procedure was primarily based on four impartial relevant parameters: pH of feed phase (4-6), pH of stripping phase (9-11), carrier concentration TBP (5-10) %, and initial metal concentration (60-120 ppm). maximum recovery efficiency of lead ions is 83.852% was virtually done following thirty one-of-a-kind experimental runs, as exact through 24-Central Composite Design (CCD). The best values for the aforementioned four parameters, corresponding to the most restoration efficiency were: 5, 10, 7.5% (v/v), and 90 mg/l, respectively. The obtained experimental data had been

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Thu Nov 01 2018
Journal Name
Environmental Technology & Innovation
Extraction of glycyrrhizin from licorice (Glycyrrhiza Glabra L.) by bulk liquid membrane
...Show More Authors

In this work, the extraction of glycyrrhizin from Licorice using bulk liquid membrane technique was developed and optimized. The effect of various parameters such as pH of stripping and donor solutions, temperature, stirring speed and kinetic parameters were investigated. Moreover, to study the impact of the polarity of membrane solvent, two types of extraction solvents were used as a membrane solvent: n-Hexane was used as a non-polar solvent and 1-Hexanol was as a polar solvent. The optimum extraction condition was found (95.53%) using 1-Hexanol, rotating speed was 400 rpm, and pH of the acceptor and donor solutions were 8 and 5.5, respectively. The reaction kinetics constants ( and ) for the transport of glycyrrhizin from the donor pha

... Show More
View Publication
Scopus (13)
Crossref (9)
Scopus Clarivate Crossref
Publication Date
Mon May 28 2018
Journal Name
Iraqi Journal Of Science
Alternative Approach to Extract the Bulk Etching Rate of PADC Nuclear Detector
...Show More Authors

     The paper aims to propose the maximum track length (Lmax) measurement as an alternative approach to evaluate and extract the bulk etch rate (Vb) of the nuclear detector PADC CR-39, and compare it with the results obtained by the removal layer thickness measurement of the etched detector. The alternative Lmax-method mainly relies on the measuring the length of the etched tracks, their maximum values and saturation times from the obtained track profile images. The detectors were irradiated with different energies of alpha particles emitted from the 241Am source and then etched in a 6.5 N NaOH solution at 70±1oC for different successive time intervals. In

... Show More
View Publication Preview PDF
Publication Date
Sat Mar 25 2023
Journal Name
International Journal Of Drug Delivery Technology
Improvement of Entrapment and Ocular Permeability of Ganciclovir Nanostructured Lipid Carriers Using Various Conditions of Preparations
...Show More Authors

Ganciclovir (GCV) is a drug included in BCS-Class III, having high solubility and low permeability. It is a synthetic acyclic nucleoside analog of 2′-deoxyguanosine, considered a potent inhibitor of herpes viruses and cytomegalovirus (CMV) infection. Herpes simplex virus (HSV) infections are very common and are also considered a major cause of corneal blindness. This study intended to advance a pioneering nanostructured lipid carriers (NLCs) system for improving the ocular permeability of GCV. Several procedures were used for the preparation. Cold homogenization, solvent injection, and emulsifi cationultrasonication methods. A mixture of palmitic acid (PA) and oleic acid (OA) as a lipid matrix, cremophore EL, and transcutol HP wer

... Show More
View Publication
Scopus (1)
Scopus Crossref
Publication Date
Wed Sep 14 2016
Journal Name
Journal Of Baghdad College Of Dentistry
Effect of Acidic and Energy Drinks on Surface Roughness of Three Types of Bulk Fill Composite Materials
...Show More Authors

ABSTRACT Background: This study aimed to study the effect of some acidic drinks (Vinegars and fresh Orange juice) and energy drinks (Red bull) on surface roughness of three types of bulkfill composite materials: Filtek posterior bulkfill (3M), Sonicfill (Kerr) and Filtek p60 (3M). Materials and Methods: Total number of 120 samples are prepared by using a mold of (12mm diameter and 3mm height), which were divided into three groups forty samples for each group: Group A: Filtek bulkfill posterior composite (3M), Group B: Sonicfill composite (Kerr), Group C: Filtek P60 (3 M) which then divided into four sub- groups (n=10) (1) samples were kept in distilled water as a control group (2) samples were immersed in Redbull (3) samples were immersed

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Tue Feb 28 2023
Journal Name
Iraqi Journal Of Science
The Performance of V2O5:Ag Nanoparticles as Thin Film and Bulk Pellet Sensor for NO2 and NH3 Detection
...Show More Authors

      A comparison of gas sensing performance of V2O5:Ag nanoparticles as thin film and as bulk pellet toward NO2 and NH3 is presented. V2O5:Ag nanoparticles thin films were deposited by vacuum thermal evaporation method on glass substrates while the pellets were prepared by powder technology. XRD patterns of thin film and pellet were polycrystalline with an orthorhombic structure. The value of average grain size is about 60 nm. The morphological properties of the samples have been distinguished by atomic force microscopy (AFM) and field effect scanning electron microscopy (FESEM) which indicated that the films showed homogeneous surfaces morphology a

... Show More
View Publication Preview PDF
Scopus (2)
Scopus Crossref
Publication Date
Fri Mar 28 2008
Journal Name
Ama, Agricultural Mechanization In Asia, Africa & Latin America
The Effect of Two Type of Plows With Four Speeds on the Field Capacity and Bulk Density
...Show More Authors

Publication Date
Mon Jun 17 2019
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
The Effect of Two Antigen Preparations From Group A Streptococcus on Phagocytosis and Cellular Counts of Neutrophils and Monocytes in Albino Mice
...Show More Authors

The phagocytic activity of peritoneal and blood cells counts with neutrophils and monocytes were evaluated in albino mice treated wtth two antigen preparations (A and B) from group A streptococci (GAS). Antigen A included water bathed bacteria at 70 °C for 60 minutes, while in Antigen B the bacteria was autoclaved at 121° C for 15 minutes. The animals were treated with 12 intraperitoneal doses of the antigens with intervals of three days (36 days). The 12th dose was a challenge dose (live bacteria). The first three doses of Antigen A increased the phagocytic index (PI) to a range of 76.46-78.69%, then a gradual decreased percentage was observed, especially at the challenge dose (PI=6.42%). The count of neutrophils and monocytes fol

... Show More
View Publication Preview PDF
Publication Date
Sun Oct 22 2023
Journal Name
Iraqi Journal Of Science
New Approach for the On-Line Spectrophotometric Determination of Vanadium (V) In Different River Water via the Use of a Homemade Ayah 6SX1-T-2D Solar-Continuous Flow Injection Analyser
...Show More Authors

A new simple sensitive and selective spectrophotometric method has been developed for the analysis of vanadium(V) in three randomly chosen samples from river water at different locations by continuous flow injection analysis. The method based on the oxidation of pyrogallol by vanadium(V) in acidic solution to form color species and the same species was determined using homemade Ayah 6SX1-T-2D solar cell analyser . Chemical and physical parameters were investigated using the high intensity of snow white light emitted diode as a source. The linear dynamic range for the instrument response versus vanadium(V) concentration was 1-200 mg.L-1 with correlation coefficient r = 0.9920. The limit of detection (S/N=3) was 70 ng/ sample from the step

... Show More
View Publication Preview PDF