This study was designed to evaluate the effect of major surgery on thyroid hormones and thyrotropin in patient undergoing major lower abdominal surgery. The study included fifty patients scheduled for elective major lower abdominal surgery, the serum levels of T3, T4 and TSH were determined one day preoperatively, intraoperative, one day postoperatively, two days postoperatively, and rT3 was determined one day preoperatively, and one day postoperatively. We observed that the levels of (T3, T4, TSH) increased significantly (P<0.05) intraoperatively, one day postoperatively the levels of T3 and T4 reduced significantly (P<0.05), while TSH reduced not significantly (P>0.05), and two days postoperatively T4 and TSH returned to increase significantly but T3 not significantly (P>0.05). rT3 increased not significant (P>0.05) in one day postoperatively. It has been proposed these changes due to surgical stress that inhibits peripheral conversion of T4 to T3 by inhibiting peripheral 5'-deiodinase activity, also The absence of pituitary response to changes in serum levels of T3 and T4.According to the results of this study there is a transient abnormality in thyroid function tests in patient undergoing elective major surgery and this abnormality due to surgical stress.
Bringing about urban, economic, and social changes in rural areas similar to those occurring in urban areas aims to reduce urban-rural disparities by providing services in those areas, decentralizing the management of these services, expanding citizen participation in local governance (decentralized administration), and achieving comprehensive development, developing and empowering localities, and keeping pace with new transformations and their impacts on the functions of the center and localities. In fact, the lack of clarity of the role of local government in planning and managing services has hindered development plans, and declined the level of services in rural areas, and has negative
... Show MoreAPDBN Rashid, Review of International Geographical Education Online (RIGEO), 2021
in this paper copper oxide (cuO thin films were prepared by the method of vacum thermal evaporation a pressure.
The osseodensification (OD) drilling technique was suggested as an alveolar ridge expansion technique, so the aim of this prospective clinical study was to evaluate the amount of bone expansion obtained by the OD drilling technique and its effect on implant stability in patients with narrow alveolar ridges. The width of the alveolar ridge was measured at the crest before and after implant site preparation, whereas the implant stability was measured using Osstell Beacon implant stability quotient (ISQ). The ISQ values were recorded immediately postoperatively and after 16 weeks. Twenty-three patients were included; they received 40 implants. The mean (± standard deviation [SD]) amount of expansion was 1.29 (± 0.41) mm, and the difference b
... Show MoreAge, hypertension, and diabetes can cause significant alterations in arterial structure and function, including changes in lumen diameter (LD), intimal-medial thickness (IMT), flow velocities, and arterial compliance. These are also considered risk markers of atherosclerosis and cerebrovascular disease. A difference between right and left carotid artery blood flow and IMT has been reported by some researchers, and a difference in the incidence of nonlacunar stroke has been reported between the right and left brain hemispheres. The aim of this study was to determine whether there are differences between the right and left common carotid arteries and internal carotid arteries in patient
Electronic properties such as density of state, energy gap, HOMO (the highest occupied molecular orbital) level, LUMO (the lowest unoccupied molecular orbital) level and density of bonds, as well as spectroscopic properties like infrared (IR), Raman scattering, force constant, and reduced masses for coronene C24, reduced graphene oxide (rGO) C24O5and interaction between C24O5and NO2gas molecules were investigated. Density functional theory (DFT) with the exchange hybrid function B3LYP with 6-311G** basis sets through the Gaussian 09 W software program was used to do these calculations. Gaussian view 05 was em
... Show MoreBackground: Implant stability is a mandatory factor for dental implant (DI) osseointegration and long-term success. The aim of this study was to evaluate the effect of implant length, diameter, and recipient jaw on the pre- and post-functional loading stability. Materials and methods: This study included 17 healthy patients with an age range of 24-61 years. Twenty-two DI were inserted into healed extraction sockets to replace missing tooth/ teeth in premolar and molar regions in upper and lower jaws. Implant stability was measured for each implant and was recorded as implant stability quotient (ISQ) immediately (ISQ0), and at 8 (ISQ8) and 12 (ISQ12) weeks postoperatively, as well as post-functional loading (ISQPFL). The pattern of implant
... Show More