A high-performance liquid chromatography method was employed for the quantitative determination of ascorbic acid (AA) which called vitamin C in three types of Iraqi citrus (orange mandarin and aurantium ) and to establish this goal , evaluation of ascorbic acid degradation is so important due to its significant criticality when exposure to ordinary atmospheric conditions. The chromatographic analysis of AA was carried out after their sequential elution with KH2PO4 ( as mobile phase) by reverse-phase HPLC technique with C8 column and UV detection at 214 nm. .Bad resolutions was appeared clearly for C8 column , so another alternative condition were carried out to improve the resolution by replacement of C8 by C18 column .Statistical treatments were used to calculate relative standard deviation (RSD%) for the results to gain acceptable confidence to the present work , so the linearity of calibration curve, accuracy, and repeatability of this method are all satisfactory.
The present study include a new developed method of analysis for determination of drug Spironolaction (SP) in some Pharmaceuticals by Spectrofluorometric method. Spironolaction was determined under optimal experimental condition that follows :- The excitation spectrum was (l=351 nm), the emmetion spectrum was (l=518 nm), pH=1, the suitable temperature for reaction 60oC and the optimal time less than (3) minute. The analysis and rang statistical data was:-Linear dynamic rang (1-10) ?g.ml-1, the detection limit (D.L = 0.023 ?g.ml-1), Molar absorptivity (? = 29875 liter mole-1 cm-1), Relative standard deviation (%RSD = 0.78), (%Erel = 3.3) and recovery (Rec = 96.6) percentage. Determination of Spironolactone was accomplished by two methods
... Show MoreThe main objectives of this research is to extract essential oil from: orange ( citrus sinensis), lemon( citrus limon) and mandarin( citrus reticulata) peels by two methods: steam distillation (SD) and microwave assisted steam distillation (MASD), study the effect of extraction conditions (weight of the sample, extraction time, and microwave power, citrus peel type) on oil yield and compare the results of the two methods, the resulting essential oil was analyzed by Gas Chromatography (GC).
Essential oils are highly concentrated substances used for their flavor and therapeutic or odoriferous properties, in a wide selection of products such as foods, medicines and cosmetics. Extracti
... Show MoreIn drilling processes, the rheological properties pointed to the nature of the run-off and the composition of the drilling mud. Drilling mud performance can be assessed for solving the problems of the hole cleaning, fluid management, and hydraulics controls. The rheology factors are typically termed through the following parameters: Yield Point (Yp) and Plastic Viscosity (μp). The relation of (YP/ μp) is used for measuring of levelling for flow. High YP/ μp percentages are responsible for well cuttings transportation through laminar flow. The adequate values of (YP/ μp) are between 0 to 1 for the rheological models which used in drilling. This is what appeared in most of the models that were used in this study. The pressure loss
... Show MoreStable new derivative of L-ascorbic acid, 5,6-O-iso propylidene 2,3-O,O acetic acid-Lascorbic acid (L) was synthesized in good yield by the reaction of 5,6-O-isopropylidene-Lascorbic acid with chloroacetic acid in presence of potassium hydroxide. The new product (L) was characterized by 1H, 13C–NMR, mass spectrum and fourier transform infrared (FTIR). The reaction of the ligand (L) with metal bivalent ion., M+2 = (Co, Ni, Cu, Cd, Hg, Mg, Ca, Pb) synthesized and characterized by FTIR, UV-Visible, Molar conductance, Atomic absorption and the molar ratio (Ni+2, Cd+2) complexes. Spectroscopic evidence showed that the binding of the M(II) ions with (L) are through the (C–I=O) Lacton and O-2-CH2COO– as a bidentate manar re
... Show MoreThis study was conducted in College of Science \ Computer Science Department \ University of Baghdad to compare between automatic sorting and manual sorting, which is more efficient and accurate, as well as the use of artificial intelligence in automated sorting, which included artificial neural network, image processing, study of external characteristics, defects and impurities and physical characteristics; grading and sorting speed, and fruits weigh. the results shown value of impurities and defects. the highest value of the regression is 0.40 and the error-approximation algorithm has recorded the value 06-1 and weight fruits fruit recorded the highest value and was 138.20 g, Gradin
Galvanic corrosion of stainless steel 316 (SS316) and carbon steel (CS) coupled in 5% wt/v sulfuric acid solution at agitation velocity was investigated. The galvanic behavior of coupled metals was also studied using zero resistance ammeter (ZRA) method. The effects of agitation velocity, temperature, and time on galvanic corrosion current and loss in weight of both metals in both free corrosion and galvanic corrosion were investigated. The trends of open circuit potential (OCP) of each metal and galvanic potential (Eg) of the couple were, also, determined. Results showed that SS316 was cathodic relative to CS in galvanic couple and its OCP was much more positive than that of CS for all investigated ranges of
... Show MoreObjectives: This study aimed to evaluate the therapeutic potential effects of ascorbic acid or and pyridoxine on diabetic renal microalbumiuria. Methods: This was a cross-sectional study on patients with diabetes mellitus at Al-Yarmouk teaching hospital from January to December 2012, Iraq-Baghdad. Twenty one patients with diabetes mellitus (D.M), 8 IDDM and 13 IDDM were selected from, the duration of disease were ranged from 2-12 years for both type (10 females and 11males) and all enrolled patients ages were ranged from 28-65years. The concentration of total protein in urine was calculated by a biuret colorimetric assay and the urine creatinine level was measured by a modified Jaffe test. Statistical analysis: results are expressed as mean
... Show MoreBoth the double-differenced and zero-differenced GNSS positioning strategies have been widely used by the geodesists for different geodetic applications which are demanded for reliable and precise positions. A closer inspection of the requirements of these two GNSS positioning techniques, the zero-differenced positioning, which is known as Precise Point Positioning (PPP), has gained a special importance due to three main reasons. Firstly, the effective applications of PPP for geodetic purposes and precise applications depend entirely on the availability of the precise satellite products which consist of precise satellite orbital elements, precise satellite clock corrections, and Earth orientation parameters. Secondly, th
... Show MoreReconstruction in Iraq requires coherent legitimate frameworks that are able to detail obligations, rights and responsibilities of the parties participating in reconstruction projects, regardless their type or delivery system.
Conditions of Contract can be considered an important component of these frameworks. This paper investigates flexibility and appropriateness of the application of Iraqi conditions of contract in reconstruction projects. These conditions were compared to FIDIC Conditions. The objective wasn't comparing individual clauses, but rather exploring the principles and philosophy laying behind each conditions, and to what extent each conditions care about realizing equity between main contract parties. Validity of applic
A spectrophotometric- reverse flow injection analysis (rFIA) method has been proposed for the determination of Nitrazepam (NIT) in pure and pharmaceutical preparations. The method is based upon the coupling reaction of NIT with a new reagent O-Coumaric acid (OCA) in the presence of sodium periodate in an aqueous solution. The blue color product was measured at 632 nm. The variation (chemical and physical parameters) related with reverse flow system were estimated. The linearity was over the range 15 - 450 µg/mL of NIT with detection limits and limit of quantification of 3.425 and 11.417 µg mL-1 NIT,respectively. The sample throughput of 28 samples
... Show More