Preferred Language
Articles
/
bsj-2006
Lettuce Leaves as Biosorbent Material to Remove Heavy Metal Ions from Industerial Wastewater

The current study was designed to remove Lead, Copper and Zinc from industrial wastewater using Lettuce leaves (Lactuca sativa) within three forms (fresh, dried and powdered) under some environmental factors such as pH, temperature and contact time. Current data show that Lettuce leaves are capable of removing Lead, Copper and Zinc ions at significant capacity. Furthermore, the powder of Lettuce leaves had highest capability in removing all metal ions. The highest capacity was for Lead then Copper and finally Zinc. However, some examined factors were found to have significant impacts upon bioremoval capacity of studied ions, where best biosorption capacity was found at pH 4, at temperature 50º C and contact time of 1 hour.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Dec 01 2011
Journal Name
Journal Of Engineering
REMOVAL OF COPPER ION FROM WASTEWATER BY FLOTATION

Several industrial wastewater streams may contain heavy metal ions, which must be effectively removal
before the discharge or reuse of treated waters could take place. In this paper, the removal of copper( II)
by foam flotation from dilute aqueous solutions was investigated at laboratory scale. The effects of
various parameters such as pH, collector and frother concentrations, initial copper concentration, air flow
rate, hole diameter of the gas distributor, and NaCl addition were tested in a bubble column of 6 cm inside
diameter and 120 cm height. Sodium dodecylsulfate (SDS) and Hexadecyl trimethyl ammonium bromide
(HTAB) were used as anionic and cationic surfactant, respectively. Ethanol was used as frothers and the

... Show More
Crossref (3)
Crossref
View Publication Preview PDF
Publication Date
Thu May 23 2013
Journal Name
Journal Of The College Of Basic Education
Synthesis and Characterization of Benzoic Acid 2-Salicylidene Complexes with Selected Metal Ions

Salicylaldehyde was reacting with 2-amino benzoic acid to produce the Schiff base ligand benzoic acid 2-salicylidene (L). The prepared ligand was identified by Microelemental Analysis, FT.IR and UV-Vis spectroscopic techniques. A new complexes of Co(II),Ni(II),Cu(II) and Zn(II) with Schiff base was prepared in aqueous ethanol with a (1:1) M:L. The prepared complexes were characterized using flame atomic absorption, (C.H.N) Analysis, FT.IR and UV-Vis spectroscopic methods as well as magnetic susceptibility and conductivity measurements. Biological activity of the ligand and complexes against three selected types of bacteria were also examined. Some of the complexes exhibit good bacterial activities. From the obtained data the tetrahedral str

... Show More
Publication Date
Sun Mar 01 2015
Journal Name
Baghdad Science Journal
Terrestrial Invertebrates as a Bioindicators of Heavy Metals Pollution

Bioaccumulation of heavy metals in the terrestrial invertebrates in Al-Jadriyia district Baghdad- Iraq were investigated. Forth terrestrial invertebrates snails, slug, isopods, and diplopods , were selected for this study. The results showed that all invertebrate groups have the ability in accumulate considerable amounts of heavy metals. Higher levels of zinc and copper were observed in the isopods specimens, it's about ( 60.50±0.58 ) and ( 96.00±0.58 ) ppm respectively , while higher levels of lead were observed in the diplopods specimens ,it's about ( 23.00±1.15 ) ppm ,but the higher levels of both iron and cadmium were observed in snail specimens , it's about ( 590.00±1.15 ) and ( 9.50±1.15 ) ppm respectively .but the

... Show More
Crossref
View Publication Preview PDF
Publication Date
Sun Feb 05 2017
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
STUDY OF OPTIMUM CONDITIONS FOR REMOVAL OF HEAVY METAL ELEMENTS BY LOCALLY ISOLATED FUNGI Aspergillus niger.: STUDY OF OPTIMUM CONDITIONS FOR REMOVAL OF HEAVY METAL ELEMENTS BY LOCALLY ISOLATED FUNGI Aspergillus niger.

The best optimum temperature for the isolate was 30○C while the pH for the maximum mineral removal was 6. The best primary mineral removal was 100mg/L, while the maximum removal for all minerals was obtained after 8 hrs, and the maximum removal efficiency was obtained after 24 hrs. The results have proved that the best aeration for maximum removal was obtained at rotation speed of 150 rpm/ minute. Inoculums of 5ml/ 100ml which contained 106 cell/ ml showed maximum removal for the isolate.

View Publication Preview PDF
Publication Date
Wed Oct 04 2023
Journal Name
Environmental Progress & Sustainable Energy
Removal of <scp>E133</scp> brilliant blue dye from artificial wastewater by electrocoagulation using cans waste as electrodes
Abstract<p>Solid‐waste management, particularly of aluminum (Al), is a challenge that is being confronted around the world. Therefore, it is valuable to explore methods that can minimize the exploitation of natural assets, such as recycling. In this study, using hazardous Al waste as the main electrodes in the electrocoagulation (EC) process for dye removal from wastewater was discussed. The EC process is considered to be one of the most efficient, promising, and cost‐effective ways of handling various toxic effluents. The effect of current density (10, 20, and 30 mA/cm<sup>2</sup>), electrolyte concentration (1 and 2 g/L), and initial concentration of Brilliant Blue dye (15 and 30 mg/L) on </p> ... Show More
Scopus Clarivate Crossref
View Publication
Publication Date
Wed May 01 2019
Journal Name
Iraqi Journal Of Science
Evaluation of Heavy Metal Accumulation in Sawa Lake Sediments, Southern Iraq using Magnetic Study

Heavy metal contamination comprises a great concern in the environment. A magnetic study combined with heavy metal analyses was performed in the Sawa Lake in Al-Muthanna governorate (southern Iraq). Concentrations of selected heavy metals (Cr, Fe, Ni, As and Pb) have been measured and magnetic susceptibility (χ) of sediment samples collected from the lake bottom was calculated.

The results confirmed that a cement plant, which is located less than two kilometers away from the lake has no contamination levels on the lake’s sediments. No enhancement in the magnetic susceptibility was observed. X-ray florescence (XRF) was performed for heavy metal analyses.

Spatial variations of χ with the mean value of 4.58 x

... Show More
View Publication Preview PDF
Publication Date
Thu Dec 09 2021
Journal Name
Journal Of Polymer Research
A new generation of cable grade poly(vinyl chloride) containing heavy metal free modifier
Abstract<p>Many additives are used to improve the performance of cables in terms of increasing their flame retardancy, thermal stability, thermal conductivity, and other characteristics. Unfortunately, most of these additives contain heavy metals. Therefore, the main objective of this study is to introduce a material representing a new generation of environmentally friendly heavy metal-free stabilizers for cable grade poly(vinyl chloride) that can compete with traditional materials in terms of performance and distinctive properties. This unique additive is Oxydtron, a synthetic silicate or simply nanocement. The tests performed are rheological properties represented by a capillary rheometry analysis, limiting o</p> ... Show More
Crossref (1)
Scopus Clarivate Crossref
View Publication
Publication Date
Sun Apr 30 2023
Journal Name
Iraqi Journal Of Science
Removal of Lead and Chromium From Industrial Wastewater by LocallyCitrobacter spp.Isolates

Biosorption is an effective method to remove toxic metals from wastewaters. In this
study biosorption of lead and chromium ions from solution was studied using
Citrobacter freundii and Citrobacter kosari isolated from industrial wastewater. The
experimental results showed that optimum grwoth temperature for both bacteria is 30oC
and the optimum pH is 7 &6 for C. freundii and C. kosari respectively. While the
optimum incubation period to remove Pb and Cr for C. freundii and C. kosari is 4 days
and 3days respectively. Also the biosorption of Pb and Cr in mixed culture of bacteria
and mixed culture of Pb and Cr was investigated. Result indicate that uptake of Cr and
Pb for C.freundii, C. kosari and in mixes cultu

... Show More
View Publication Preview PDF
Publication Date
Sun Apr 30 2023
Journal Name
Iraqi Journal Of Science
Removal of Lead and Chromium From Industrial Wastewater by LocallyCitrobacter spp.Isolates

Biosorption is an effective method to remove toxic metals from wastewaters. In this
study biosorption of lead and chromium ions from solution was studied using
Citrobacter freundii and Citrobacter kosari isolated from industrial wastewater. The
experimental results showed that optimum grwoth temperature for both bacteria is 30oC
and the optimum pH is 7 &6 for C. freundii and C. kosari respectively. While the
optimum incubation period to remove Pb and Cr for C. freundii and C. kosari is 4 days
and 3days respectively. Also the biosorption of Pb and Cr in mixed culture of bacteria
and mixed culture of Pb and Cr was investigated. Result indicate that uptake of Cr and
Pb for C.freundii, C. kosari and in mixes cultu

... Show More
View Publication Preview PDF
Publication Date
Fri Jul 01 2016
Journal Name
Journal Of Engineering
Aluminum Rubbish as a Coagulant for Oily Wastewater Treatment

In this study an experimental work was done to study the possibility of using aluminum rubbish material as a coagulant to remove the colloidal particles from oily wastewater by dissolving this rubbish in sodium hydroxide solution. The experiments were carried out on simulated oily wastewater that was prepared at different oil concentrations and hardness levels (50, 250, 500, and 1000) ppm oil for (2000, 2500, 3000, and 3500) ppm CaCo3 respectively. The initial turbidity values were (203, 290, 770, and 1306) NTU, while the minimum values of turbidity that have been gained from the experiments in NTU units were (1.67, 1.95, 2.10, and 4.01) at best sodium aluminate dosages in milliliters (12, 20, 24, and 28) for

... Show More
View Publication Preview PDF