Low conversion copolymerization of N-vinyl-2-pyrrolidon M.W = (111.14) VP (monomer-1) has been conducted with acrylic acid AA and methymethacrylate MMA in ethanol at 70ºC , using Benzoyl peroxide BPO as initiator . The copolymer composition has been determined by elemental analysis. The monomer reactivity ratios have been calculated by the Kelen-Tudos and Finman-Ross graphical procedures . The derived reactivity ratios (r1 , r2 ) are : (0.51 , 4.85) for (VP / AA ) systems and (0.34 , 7.58) for (VP , MMA) systems , and found the reactivity ratios of the monomer AA , MMA is mor than the monomer VP in the copolymerization of (VP / AA) and (VP /MMA) systems respectly . The reactivity ratios values were used for microstructures calculation.
KE Sharquie, AA Noaimi, GA Ibrahim, AS Al-Husseiny, Our Dermatology Online, 2016 - Cited by 3
Let f and g be a self – maps of a rational exterior space . A natural number m is called a minimal coincidence period of maps f and g if f^m and g^m have a coincidence point which is not coincidence by any earlier iterates. This paper presents a complete description of the set of algebraic coincidence periods for self - maps of a rational exterior space which has rank 2 .
Background: The healing period for bone–implant contact takes 3–6 months or even longer. Application of Escherichia coli-derived recombinant human bone morphogenetic protein-2 (ErhBMP-2) to implant surfaces has been of great interest on osseointegration due to its osteoinductive potential. The objective of this study was to evaluate the effect of ErhBMP-2 on implant stability. Materials and methods: A total of 48 dental implants were inserted in 15 patients. Twenty four implants coated with 0.5 mg/ml ErhBMP-2 (study group). The other 24 implants were uncoated (control group). Each patient was received at least two dental implants at the same session. Both groups were followed with repeated implant stability measurements by me
... Show MoreInterleukins (IL-2 and IL-4) are increased in asthmatics and were reported to induce resistance to steroid therapy in some patients who fail to get benefit from glucocorticoids when used in full dose and for long period of time. In this context, the present study was conducted on Iraqi patients to provide additional laboratory mean, beside the clinical diagnosis, for the decision whether the asthma is steroid sensitive or resistant by monitoring the level of immunoglobulins, complement proteins and interleukins among asthmatic patients (steroid sensitive or resistant) and the possible contribution of other factors like age, sex and environments in the development of steroid resistance. A total number of 55 asthmatics and 28 normal subjec
... Show MoreTo elucidate the anti- Methicillin resistance Staphylococcus aureus (MRSA) effect of pomegranate alone and in combination with moxifloxacin fluoroquinolone. A total of five clinical isolates of MRSA (ATCC 43300) were used in the study. Disc diffusion method was used to determine the anti-MRSA effect of pomegranate and/or moxifloxacin by using Mueller-Hinton agar. Minimal inhibitory concentration (MIC), fractional inhibitory concentration (FIC) of moxifloxacin and pomegranate were calculated, the dynamic picture of the bactericidal effect of pomegranate and/or moxifloxacin was determined. SPSS version 20.00 was used for data analysis. Zone of inhibition (ZOI) of moxifloxacin was 19.67±4.84mm which was not significant compared with pomegrana
... Show MoreOptical fiber chemical sensor based surface Plasmon resonance for sensing and measuring the refractive index and concentration for Acetic acid is designed and implemented during this work. Optical grade plastic optical fibers with a diameter of 1000μm were used with a diameter core of 980μm and a cladding of 20μm, where the sensor is fabricated by a small part (10mm) of optical fiber in the middle is embedded in a resin block and then the polishing process is done, after that it is deposited with about (40nm) thickness of gold metal and the Acetic acid is placed on the sensing probe.
A simple setup of random number generator is proposed. The random number generation is based on the shot-noise fluctuations in a p-i-n photodiode. These fluctuations that are defined as shot noise are based on a stationary random process whose statistical properties reflect Poisson statistics associated with photon streams. It has its origin in the quantum nature of light and it is related to vacuum fluctuations. Two photodiodes were used and their shot noise fluctuations were subtracted. The difference was applied to a comparator to obtain the random sequence.
HR Al-Hamamy, AA Noaimi, IA Al-Turfy, AI Rajab, Journal of Cosmetics, Dermatological Sciences and Applications, 2015