Preferred Language
Articles
/
bsj-1437
Biotreatment of AL-KARAMA Teaching Hospital Wastewater Using Aerobic Packed Bed
...Show More Authors

This study is aimed to use the aerobic packed bed in biotreatment of the wastewater which is discharge from AL-KARAMA teaching hospital in Baghdad. The performance of packed-bed treatment method was examined for elimination of the organic compounds from wastewater under aerobic conditions. In this research different parameters were studied. They were: inoculums concentration, circulation rate of wastewater through the bed, packing type and the temperature. Results showed that the system efficiently removed about 82% of the chemical oxygen demand (COD) and 80% of the Biological oxygen demand (BOD). Percent reduction in turbidity was about 92% and reduction in nitrate concentration was about 87%. It was found that best performance of the packed bed method was obtained at temperature of 37 oC, circulation rate of 10 L/min and inoculums concentration of 3%.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Sep 07 2008
Journal Name
Baghdad Science Journal
Detection of Pseudomonas aeruginosa in Hospital Contamination
...Show More Authors

The Present investigation includes the isolation and identification of Pseudomonas aeruginosa for different cases of hospital contamination from 1/ 6/2003 to 30/9/2004, the identification of bacteria depended on morphological , cultural and biochemical characters, 37 of isolates were diagnosed from 70 smears from wounds and burns beside 25 isolates were identified from 200 smears taken from operation theater and hospital wards including the floors , walls , sources of light and operation equipment the sensitivity of all isolates to antibiotic were done , which exhibited complete sensitivity to Ciprofloxacin , Ceftraixon, Tobromycin and Gentamysin ,while they were complete resist to Amoxcillin , Tetracyclin , Nitrofurantion , Clindamycin C

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Mar 01 2019
Journal Name
Al-khwarizmi Engineering Journal
Improving Wear Properties of 392 Al Alloy Using Centrifugal Casting
...Show More Authors

The microstructure and wear properties of 392 Al alloy with different Mg contents were studied using centrifugal casting. All melted alloys were heated to 800 ºC and poured into the preheated centrifugal casting mold (200-250 ºC) at different mould rotational speeds (1500, 1900 and 2300 r.p.m).  It is clear from the results obtained that wear rate was dependent on the Mg content, applied load and mould rotational speed. Furthermore, wear test showed that the minimum wear rate was found in the inner layer of produced rings at mould rotational speed of 1900 r.p.m and Mg content of 5%.

 

View Publication Preview PDF
Publication Date
Tue Jun 21 2022
Journal Name
Journal Of Petroleum Research And Studies
Drag Reduction of AL-Ahdab Crude Oil Using Chemical Additives
...Show More Authors

The viscosity of crude oil has a crucial role in drag reduction during pipeline transportation; hence additives are required to enhancing the flow properties of AL-Ahdab crude oil. In this work, the potato starch biopolymer and CTAB surfactant are utilized to achieve the target. The drag reduction experiments were carried out at different crude oil flow rates (20-35-50 liters/min), pipe diameters (0.5-0.75 -1 inch), and different concentrations of potato starch (500-2000 ppm) and CTAB (100-500 ppm). The results showed that these additives had minimized flow resistance in various operating conditions, the drag reduction percent increased with increasing of additives concentration increase. The maximum drag reduction achieved using CT

... Show More
View Publication
Crossref
Publication Date
Thu Nov 01 2018
Journal Name
Journal Of Economics And Administrative Sciences
The Extent of application the principles of total quality management in Improving health services in hospitals exploratory study at Al-kindi hospital / Baghdad health department Rusafa
...Show More Authors

Abstract :

The purpose of the subject of Total quality management is an important management style in organizations including hospitals through the achievement of this method of success in the administration to include        this approach describes the provision of health services and make adjustment and suggestions that  help to improve the quality of health care on an ongoing basis . Hence the idea of the study to shed light on the reality of the application of principles of  Total quality management and to highlight the quality of health services provided in al-kindi hospital / Baghdad health department rusafa and the staff at the hospital were included to find out the appl

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sat Nov 28 2020
Journal Name
The Iraqi Journal Of Science
Removal of Aniline Blue from Textile Wastewater using Electrocoagulation with the Application of the Response Surface Approach
...Show More Authors

This paper investigated the treatment of textile wastewater polluted with aniline blue (AB) by electrocoagulation process using stainless steel mesh electrodes with a horizontal arrangement. The experimental design involved the application of the response surface methodology (RSM) to find the mathematical model, by adjusting the current density (4-20 mA/cm2), distance between electrodes (0.5-3 cm), salt concentration (50-600 mg/l), initial dye concentration (50-250 mg/l), pH value (2-12 ) and experimental time (5-20 min). The results showed that time is the most important parameter affecting the performance of the electrocoagulation system. Maximum removal efficiency (96 %) was obtained at a current density of 20 mA/cm2, distance be

... Show More
Crossref (8)
Crossref
Publication Date
Wed Jan 01 2020
Journal Name
Aip Conf. Proc.
Removal of chromium ions from a real wastewater of leather industry using electrocoagulation and reverse osmosis processes
...Show More Authors

This study focused on treatment of real wastewater rejected from leather industry in Al-Nahrawan city in Iraq by Electrocoagulation (EC) process followed by Reverse Osmosis (RO) process. The successive treatment was applied due to high concentration of Cr3+ ions (about 1600 ppm) rejected in wastewater of this industry and for applying EC with moderate power consumption and better results of produced water. In Electrocoagulation process (EC), the effect of NaCl concentration (1.5, 3 g/l), current density (C.D.) (15-25 mA/cm2), electrolysis time (1-2 h), and distance between electrodes (E.D.) (1-2 cm) were examined in a batch cell by implementing Taguchi experimental design. According to the results obtained from multiple regression and signa

... Show More
View Publication Preview PDF
Scopus (22)
Crossref (17)
Scopus Crossref
Publication Date
Sun Mar 30 2008
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
A Quantitative Analysis of the Mixing of Three Solids Different in Density by an Air Fluidized Bed
...Show More Authors

Three cohesionless free flowing materials of different density were mixed in an air fluidized bed to study the mixing process by calculating performance of mixing index according to Rose equation (1959) and to study the effect of four variables (air velocity, mixing time, particle size of trace component and concentration of trace component) on the mixing index and as well as on mixing performance. It was found that mixing index increases with increasing the air velocity, mixing time and concentration of trace component until the optimum value. Mixing index depends on the magnitude of difference in particle size The first set of experiments (salt then sand then cast iron) give higher mixing index and better performance of mixing than the

... Show More
View Publication Preview PDF
Publication Date
Wed Aug 28 2019
Journal Name
Journal Of Engineering
Treatment of Simulated Carwash Wastewater by Electrocoagulation with Sonic Energy
...Show More Authors

Oily carwash wastewater is a high organic and chemical wastewater. This paper targeted to investigate a treatment to decrease the water consumption and contaminants in car-washing stations. Electrocoagulation combined with ultrasonic energy (Sono-Electrocoagulation) was suggested so that the carwash wastewater is treated to be reused. The effect of both the voltage and time of treatment on the removal of COD, turbidity, conductivity, and total dissolved solids (TDS) were studied at constant initial pH 7 and electrode distance 2 cm. The results showed the best results of removal COD, turbidity, TDS, and reduce electrical conductivity is when the voltage was 30 V and a treatment time of 90 minutes.

  <

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Sun Sep 01 2013
Journal Name
Journal Of Economics And Administrative Sciences
Using median rule in determining the establishment of service station between Al hasaka and Al kamishly serian cities
...Show More Authors

Research indicates that the second half of the twentieth century marked large interests in the service industry by government and private organizations in that one, and the service industry has become the bedrock of plans in achieving economic and social development. From this standpoint felt specialists and researchers the importance of transport modes, including rail, which should be available between Almnltq Civil populated as services organized by the competent authorities to achieve the active participation of citizens in economic and social development in the region and that the term services means economic activities, which are the results Pollack concrete such as accepting the situation and satisfaction them or satisfacti

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Nov 01 2016
Journal Name
Journal Of Engineering
Ultrafiltration and Reverse Osmosis Membranes for Treating Wastewater Effluent from Gas Turbine Power Plants using the Statistical Method of Taguchi
...Show More Authors

A study on the treatment and reuse of oily wastewater generated from the process of fuel oil treatment of gas turbine power plant was performed. The feasibility of using hollow fiber ultrafiltration (UF) membrane and reverse osmosis (RO) membrane type polyamide thin-film composite in a pilot plant was investigated. Three different variables: pressure (0.5, 1, 1.5 and 2 bars), oil content (10, 20, 30 and 40 ppm), and temperature (15, 20, 30 and 40 ᵒC) were employed in the UF process while TDS was kept constant at 150 ppm. Four different variables: pressure (5, 6, 7 and 8 bar), oil content (2.5, 5, 7.5 and 10 ppm), total dissolved solids (TDS) (100, 200,300 and 400 ppm), and temperature (15, 20, 30 and 40 ᵒC) were mani

... Show More
View Publication Preview PDF