The nature and intensity of the association of myasthenia gravis (MG) with distinct human leukocyte antigen (HLA) haplotypes differ between ethnic populations, so this study determined the association of HLA class II antigens with myasthenia gravis (MG) in Iraq.The study included Iraqi patients diagnosed with MG and two control groups the first of 54 insulin dependent diabetes mellitus patients and the second of 237 subjects as a normal control group. The test used was microlymphocytotoxicity test.The work was done in the Teaching Laboratories/Medical City/Baghdad.Results: positive associations were observed (etiological risk factors) as follows: 1. HLA-DR locus showed one positively associated allele when compared to healthy control and this was HLA-DR3 (RR: 21.05, EF0.73, & P value ? 0.05), While when compared to IDDM control no significant association appeared (since the same allele is positively associated with IDDM). 2. HLA-DQ locus showed only one positively associated allele when compared to healthy control; this was HLA-DQ2 (RR 4.67, EF 0.50, and P value ? 0.05). While no significant association appeared when compared to IDDM control. Other important clinical association were observed; association with age, gender, strong stressful events, thymoma, and other autoimmune disorders. Conclusion: The positively associated antigens which were found as follows HLA-DR3 and HLA-DQ2, while no negative association was detected.
This study deals with the elimination of methyl orange (MO) from an aqueous solution by utilizing the 3D electroFenton process in a batch reactor with an anode of porous graphite and a cathode of copper foam in the presence of granular activated carbon (GAC) as a third pole, besides, employing response surface methodology (RSM) in combination with Box-Behnk Design (BBD) for studying the effects of operational conditions, such as current density (3–8 mA/cm2), electrolysis time (10–20 min), and the amount of GAC (1–3 g) on the removal efficiency beside to their interaction. The model was veiled since the value of R2 was high (>0.98) and the current density had the greatest influence on the response. The best removal efficiency (MO Re%)
... Show MoreThis study expands the state of the art in studies that assess torsional retrofit of reinforced concrete (RC) multi-cell box girders with carbon fiber reinforced polymer (CFRP) strips. The torsional behavior of non-damaged and pre-damaged RC multi-cell box girder specimens externally retrofitted by CFRP strips was investigated through a series of laboratory experiments. It was found that retrofitting the pre-damaged specimens with CFRP strips increased the ultimate torsional capacity by more than 50% as compared to the un-damaged specimens subjected to equivalent retrofitting. This indicated that the retrofit has been less effective for the girder specimen that did not develop distortion beforehand as a result of pre-loading. From
... Show MoreCombining different treatment strategies successively or simultaneously has become recommended to achieve high purification standards for the treated discharged water. The current work focused on combining electrocoagulation, ion-exchange, and ultrasonication treatment approaches for the simultaneous removal of copper, nickel, and zinc ions from water. The removal of the three studied ions was significantly enhanced by increasing the power density (4–10 mA/cm2) and NaCl salt concentration (0.5–1.5 g/L) at a natural solution pH. The simultaneous removal of these metal ions at 4 mA/cm2 and 1 g NaCl/L was highly improved by introducing 1 g/L of mordenite zeolite as an ion-exchanger. A remarkable removal of heavy metals was reported
... Show MoreDifferent parameters of double pipe helical coil were investigation experimentally. Four coils were used; three with a curvature ratio (0.037, 0.031, and 0.028) and 11mm diameter of the inner tube while the fourth with 0.033 curvature ratio and 13 mm diameter of the inner tube. The hot water flow in the inner tube whereas the cold water flows in the annulus. The inlet temperatures of hot and cold water are 50 0C and 18 0C respectively. The inner mass flow rate ranges from 0.0167 to 0.0583 kg/s. The results show the Nusselt number increase with increase curvature ratio. The Nusselt number of the coil with 0.037 curvature ratio increases by approximately 12.3 % as compare with 0.028 curvature ratio. The results also r
... Show MoreA survey statistician for cholera in Iraq for 1980 and until 2003 show that cholera is endemic in Iraq and that the highest number of casualties recorded in the years 1998-1999 and increasing spread of the disease during the wars in hot climates, wet a study bacteriological used where circles selective and tests Alkouhaoah examinations serological system