Preferred Language
Articles
/
bsj-1392
Batch and Flow-Injection Spectrophotometric Determination of Procaine HCl in Pharmaceutical Preparations Via Using Diazotization and Coupling Reaction
...Show More Authors

Simple and sensitive batch and Flow-injection spectrophotometric methods for the determination of Procaine HCl in pure form and in injections were proposed. These methods were based on a diazotization reaction of procaine HCl with sodium nitrite and hydrochloric acid to form diazonium salt, which is coupled with chromatropic acid in alkaline medium to form an intense pink water-soluble dye that is stable and has a maximum absorption at 508 nm. A graphs of absorbance versus concentration show that Beer’s law is obeyed over the concentration range of 1-40 and 5-400 µg.ml-1 of Procaine HCl, with detection limits of 0.874 and 3.75 µg.ml-1 of Procaine HCl for batch and FIA methods respectively. The FIA average sample throughput was 70 h-1. All different chemical and physical experimental parameters that affecting on the development and stability of the colored product were carefully studied and the proposed methods were applied satisfactorily for the determination of Procaine HCl in an injections samples using the standard addition method.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Jun 01 2023
Journal Name
Baghdad Science Journal
Simultaneous Determination of Piroxicam and Codeine Phosphate Hemihydrate in a Pharmaceutical Dosage Form Using Validated HPLC Method
...Show More Authors

An easy, eclectic, precise high-Performance Liquid Chromatographic (HPLC) procedure was evolved and validated to estimate of Piroxicam and Codeine phosphate. Chromatographic demarcation was accomplished on a C18 column [Use BDS Hypersil C18, 5μ, 150 x 4.6 mm] using a mobile phase of methanol: phosphate buffer (60:40, v/v, pH=2.3), the flow rate was 1.1 mL/min, UV detection was at 214 nm. System Suitability tests (SSTs) are typically performed to assess the suitability and effectiveness of the entire chromatography system. The retention time for Piroxicam was found to be 3.95 minutes and 1.46 minutes for Codeine phosphate. The evolved method has been validated through precision, limit of quantitation, specificity,

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Wed Dec 13 2023
Journal Name
Journal Of Law And Interscience
The effects of the responsibility of the researcher who discovered pharmaceutical preparations
...Show More Authors

The process of discovering pharmaceuticals is of great importance in our contemporary life, in a way that without life becomes almost impossible, as this process is the first building block in the field of pharmaceutical industries to search for new methods and means of treatment and treatment. This process results in the commitment of the discoverer to a set of obligations in the face of the volunteer. This responsibility or negation of intentional infliction of damage by means of what is known in the law as methods of paying liability

View Publication
Publication Date
Fri Jan 01 2021
Journal Name
Analytical And Bioanalytical Chemistry Research
Mutual Derivatization in the Determination of Dapsone and Thymol Using Cloud Point Extraction Followed by Spectrophotometric Detection
...Show More Authors

A procedure for the mutual derivatization and determination of thymol and Dapsone was developed and validated in this study. Dapsone was used as the derivatizing agent for the determination of thymol, and thymol was used as the derivatizing agent for the determination of Dapsone. An optimization study was performed for the derivatization reaction; i.e., the diazonium coupling reaction. Linear regression calibration plots for thymol and Dapsone in the direct reaction were constructed at 460 nm, within the concentration range of 0.3-7 μg ml-1 for thymol and 0.3-4 μg ml-1 for Dapsone, with limits of detection 0.086 and 0.053 μg ml-1, respectively. Corresponding plots for the cloud point extraction of thymol and Dapsone were constructed

... Show More
Scopus (1)
Scopus
Publication Date
Tue Mar 01 2016
Journal Name
Journal Of Engineering
Semi-Batch Reactive Distillation of Consecutive Reaction : The Saponification Reaction of Diethyl Adipate with Sodium Hydroxide Solution
...Show More Authors

This research presents a new study in reactive distillation by using consecutive reaction: the saponification reaction of diethyl adipate (DA) with sodium hydroxide solution .

The effect of three parameters were studied through a design of experiments applying 23 factorial design . These parameters were : the mole ratio of DA to NaOH solution (0.1 and 1) , NaOH solution concentration (3 N and 8 N) , and batch time (1.5 hr. and 3.5 hr.) . The conversion of DA to sodium monoethyladipate(SMA)(intermediate product) was the effect of these parameters which was detected . Also , the percentage purity of the intermediate product was recorded . The results showed that increasing mole ratio of DA to NaOHsolutio

... Show More
View Publication Preview PDF
Publication Date
Wed Mar 10 2021
Journal Name
Baghdad Science Journal
carcinogenicity of cadmium chloride via intraoeritoneal injection in albino rats
...Show More Authors

Observed visually prominent lumps on the surface of the lung or embedded in lung tissue and microscopically Register Anfaj thrombosis with pulmonary carcinoma that took shape food or with the composition of the vesicles papillomavirus lining cells cubic vertical or connective tissue and increase

View Publication Preview PDF
Publication Date
Sun Sep 01 2019
Journal Name
Baghdad Science Journal
Kinetic- spectrophotometric Method for the Determination of Naringenin in Pure and Supplements Formulations
...Show More Authors

          Simple, cheap, sensitive, and accurate kinetic- spectrophotometric method has been developed for the determination of naringenin in pure and supplements formulations. The method is based on the formation of Prussian blue. The product dye exhibits a maximum absorbance at 707 nm. The calibration graph of naringenin was linear over the range 0.3 to 10 µg ml-1 for the fixed time method (at 15 min) with a correlation coefficient (r) and percentage linearity (r2%) were of 0.9995 and 99.90 %, respectively, while the limit of detection LOD was 0.041 µg ml-1. The method was successfully applied for the determination of naringenin in supplements with satisfac

... Show More
View Publication Preview PDF
Scopus (2)
Scopus Clarivate Crossref
Publication Date
Sun Jun 11 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Using of Third and Fourth Order Derivative Spectra to Simultaneous Determination of Olanzapine and Ephedrine in Its Pure and Pharmaceutical Formulations
...Show More Authors

 Two new simultaneous spectrophotometric methods for determination of Olanzapine and Ephedrine depend on third (D3) and fourth (D4) derivative of zero spectrum of two drugs were developed. The peak – to- base line, peak to peak and area under peak were found proportional with concentration of the drugs up to (4-24 µg/ml-1) at known experimental wavelengths. The results showed that the method was precise and accurate through  RSD% (0.5026-4.0273),( 0.2399 6.9888) and  R.E %(-2.3889-0.8333) ,) -2.9444-0.2273) while the LOD (0.0057-  0.8510 μg.ml-1), ( 0.0953-0.9844 μg.ml-1) and LOQ (0.0173- 2.5788μg.ml-1),( 0.5774-2.9829 μg.ml-1) were found for the two drugs respectively. The methods were applied i

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Dec 31 2020
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
DISPERSIVE LIQUID LIQUID MICRO EXTRACTION SPECTROPHOTOMETRIC DETERMINATION OF TELMESARTAN AND IRBESARTAN IN PHARMACEUTICALS SAMPLES: DISPERSIVE LIQUID LIQUID MICRO EXTRACTION SPECTROPHOTOMETRIC DETERMINATION OF TELMESARTAN AND IRBESARTAN IN PHARMACEUTICALS SAMPLES
...Show More Authors

The current work is characterized by simplicity, accuracy and high sensitivity Dispersive liquid - Liquid Micro Extraction (DLLME). The method was developed to determine Telmesartan (TEL) and Irbesartan (IRB) in the standard and pharmaceutical composition. Telmesartan and Irbesartan are separated prior to treatment with Eriochrom black T as a reagent and formation ion pair reaction dye. The analytical results of DLLME method for linearity range (0.2- 6.0) mg /L for both drugs, molar absorptivity were (1.67 × 105-    5.6 × 105) L/ mole. cm, limit of detection were (0.0242and0.0238), Limit of quantification were (0.0821and0.0711), the Distribution coefficient were

... Show More
View Publication Preview PDF
Publication Date
Sat Jan 27 2024
Journal Name
History Of Medicine
Developing and Validating a Spectrophotometric Method for Estimating Antifungal (Nystatin) in its Pure Form Pharmaceutical Formulation Using Tetrachloro-1,4 benzoquinone
...Show More Authors

The UV−VIS absorption spectroscopy technique was used to study the formation of a new complex of charge transfer (CT) between bioactive organic molecules as (Nystatin) containing both a π-electrons from a conjugated system and lone-pair of electrons (amine) with Tetrachloro-1,4 benzoquinone (TCBQ) as a π-acceptor in which the transferred electron goes into its vacant anti-bonding molecular orbitals. The Tyrian purple-colored complex formed was quantitatively measured at 544 nm. This complex shows obeying Beer's law within the concentration range of (10-90) μg.ml-1The stoichiometry of the formed complex between the (Nys.) and (TCBQ) was found 1:2 as evaluated by continuous variation (Job's method) and mole ratio method The value of mola

... Show More
View Publication Preview PDF
Publication Date
Sun Jun 06 2010
Journal Name
Baghdad Science Journal
Rapid Spectrophotometric Determination of Phenoxazine
...Show More Authors

A rapid high sensitive and inexpensive economic method has been developed for the Determination of phenoxazine by using molecular spectrophotometry. The method is based on the oxidation of phenoxazine by potassium (meta)periodate in acidic medium. The oxidation conditions were selected to enhance the sensitivity and the stability of the pink colored species which shows an absorption maximum at 530 nm. The Beer’s law was obeyed for phenoxazine concentration range from 1 to 6 µg mL-1 with 0.003 µg mL-1 detection limit and provided variation coefficients between 0.4 to 1.7 %. This method was successfully applied for the determination of phenoxazine in aqueous samples

View Publication Preview PDF
Crossref