The reliability of optical sources is strongly dependent on the degradation and device characteristics are critically dependent on temperature. The degradation behaviours and reliability test results for the laser diode device (Sony-DL3148-025) will be presented .These devices are usually highly reliable. The degradation behaviour was exhibited in several aging tests, and device lifetimes were then estimated. The temperature dependence of 0.63?m lasers was studied. An aging test with constant light power operation of 5mW was carried out at 10, 25, 50 and 70°C for 100hours. Lifetimes of the optical sources have greatly improved, and these optical sources can be applied to various types of transmission systems. Within this degradation range, the device life for system application is estimated to be more than 100 h at 70 ºC at a constant power of 5mW.
Incivility in nursing education can negatively affect the academic achievement. As there is no tool in Arabic to assess incivility among nursing students, there is a need for a valid and reliable tool.
This study aimed to investigate the psychometric properties of the Arabic version of the Incivility in Nursing Education- Revised (INE-R) survey.
Th
Thermal energy storage is an important component in energy units to decrease the gap between energy supply and demand. Free convection and the locations of the tubes carrying the heat-transfer fluid (HTF) have a significant influence on both the energy discharging potential and the buoyancy effect during the solidification mode. In the present study, the impact of the tube position was examined during the discharging process. Liquid-fraction evolution and energy removal rate with thermo-fluid contour profiles were used to examine the performance of the unit. Heat exchanger tubes are proposed with different numbers and positions in the unit for various cases including uniform and non-uniform tubes distribution. The results show that
... Show MoreCO2 laser (10.6 μm) is the most often used laser in the oral surgery due to its high absorption by water of the oral tissues. Several benefits of the use of CO2 laser have been reported for oral surgical procedures. This study aims to evaluate the effect of CO2 laser on soft and hard oral tissues (in vitro study). This study was done on fresh tissues from sheep’s head. CO2Surgical Laser with different operation modes was used; 0.2 mm spot size using different laser parameters on the tongue, and bone making holes, incisions and cutting. The depths and widths of holes and incisions were measured using endodontic file under magnification. The speed of incisions was calculated and the required time for cutting was measured using sport clo
... Show MoreBackground: breast cancer is commonest cancer globally and the 1st cancer in Iraq among females, its management and prognosis depend on early diagnosis, the traditional method was excisional biopsy which is expensive and invasive leading to delayed diagnosis, FNAB is cheap nom invasive more acceptable to women, Aim of the study: to test the reliability of FNAB in preoperative diagnosis of breast lump.
Methodology: This is a retrospective study of 204 cases, 102 breast cancer cases and 102 benign breast lesions, taken between Jan. 2017 – Nov. 2017. The sample taken from the breast cancer early detection center in Al-Alwiyaa maternity teaching hospital, during the year 2017
... Show MoreIn this study, iron was coupled with copper to form a bimetallic compound through a biosynthetic method, which was then used as a catalyst in the Fenton-like processes for removing direct Blue 15 dye (DB15) from aqueous solution. Characterization techniques were applied on the resultant nanoparticles such as SEM, BET, EDAX, FT-IR, XRD, and zeta potential. Specifically, the rounded and shaped as spherical nanoparticles were found for green synthesized iron/copper nanoparticles (G-Fe/Cu NPs) with the size ranging from 32-59 nm, and the surface area was 4.452 m2/g. The effect of different experimental factors was studied in both batch and continuous experiments. These factors were H2O2 concentration, G-Fe/CuNPs amount, pH, initial DB15
... Show MoreIn this paper, we derived an estimators and parameters of Reliability and Hazard function of new mix distribution ( Rayleigh- Logarithmic) with two parameters and increasing failure rate using Bayes Method with Square Error Loss function and Jeffery and conditional probability random variable of observation. The main objective of this study is to find the efficiency of the derived of Bayesian estimator compared to the to the Maximum Likelihood of this function using Simulation technique by Monte Carlo method under different Rayleigh- Logarithmic parameter and sample sizes. The consequences have shown that Bayes estimator has been more efficient than the maximum likelihood estimator in all sample sizes with application
In earthquake engineering problems, uncertainty exists not only in the seismic excitations but also in the structure's parameters. This study investigates the influence of structural geometry, elastic modulus, mass density, and section dimension uncertainty on the stochastic earthquake response of a multi-story moment resisting frame subjected to random ground motion. The North-south component of the Ali Gharbi earthquake in 2012, Iraq, is selected as ground excitation. Using the power spectral density function (PSD), the two-dimensional finite element model of the moment resisting frame's base motion is modified to account for random ground motion. The probabilistic study of the moment resisting frame structure using stochastic fin
... Show More(phen) (L(M [formula general a with complexes ligand-mixed new of series A methods analyses different by characterised and synthesised been have ,ligand arysecond as phenanthroline1,10- = phen and ligand primary as dithiocarbamate-1-azolebenzoimid-H-1)sulfinyl)methyl)yl-”-2pyriden)trifluroethoxy2,2,2- “(-4-methyl3-(((2-Sodium = L,ZnIIandCdII,CuII,NiII,CoII= M where,Cl)]phen)(L(Pd [Cland]2)O2H( ligands to metal ,moments magnetic and ,elementalanalysis ,spectrum mass ,surementsmea conductivity ,analysis thermal ,spectroscopy Vis-UV ,IR-FT ,NMR-C,13 H1 such dithiocarbamate the with formed coordination anisobidentate that showed spectra IRFT The.)phen:dithiocarbamate:M) (1:1:1(be to found been has complexes all in ratio nitrogen th
... Show MoreBackground: Soft Laser has been advantageous in medical applications and is widely used in clinical practice. It is applied because it doesn’t cause the significant thermal effects or tissue hurt when irradiated. The blood response to low power laser radiation provides information about processes of laser radiation interaction with live creatures. Objective: The aim of the current work was to evaluate the laser-induced changes of in vitro erythrocyte sedimentation rate (ESR), mean corpuscular volume (MCV), and mean corpuscular hemoglobin concentration (MCHC) in patients with breast cancer by irradiating a human blood sample using a green laser and comparing its effects before and after irradiation with the same power density (100mW/c
... Show More