Preferred Language
Articles
/
bsj-1342
Oilfield Produced Water Management: Treatment, Reuse and Disposal
...Show More Authors

Produced water is accompanied with the production of oil and gas especially at the fields producing by water drive or water injection. The quantity of these waters is expected to be more complicated problem with an increasing in water cut which is expected to be 3-8 barrels water/produced barrel oil.Produced water may contain many constituents based on what is present in the subsurface at a particular location. Produced water contains dissolved solids and hydrocarbons (dissolved and suspended) and oxygen depletion. The most common dissolved solid is salt with concentrations range between a few parts per thousand to hundreds parts per thousand. In addition to salt, many produced waters also contain high levels of heavy metals like zinc, barium, chromium, lead, nickel, uranium, vanadium and low levels of naturally occurring radioactive materials (NORM).This study will highlight the main aspects of the different international experiences with the produced water treatment for subsequent reuse or disposal. These different treatment methods vary considerably in effectiveness, cost and their environmental impacts. Samples of produced water from Al-Mishrif formation in ten wells belongs to five fields southern Iraq were taken and analyzed chemically to define the basic features of these waters and to have guide lines for the best strategy that required handling the increased water cut in these fields.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon May 31 2021
Journal Name
Indian Journal Of Ecology
Identification and Antimicrobial Susceptibility Profiles of Salmonella spp. Isolated from Chicken Flocks and their Feed and Water in Karbala, Iraq
...Show More Authors

The objective of study was determining the most prevalent Salmonella spp. and their antimicrobial susceptibility in broilers and laying chickens and their feed and drinking water in five chicken farms in Karbala, Iraq over the period from August to October 2020. A total of 289 samples, including 217 cloaca swabs, 46 water and 26 feed samples were collected. Salmonella spp. was identified firstly by routine diagnostic methods, followed by applying the API 20E kit, the Vitek2 system, and serology. There was significant differences in Salmonella prevalence among different types of samples, mainly cloaca swabs reported a high isolation rate (21.7%). In contrast, feed samples were completely free of contamination. The highest rate of isolation w

... Show More
Preview PDF
Publication Date
Fri Jun 01 2018
Journal Name
Journal Of Engineering
Determining and Predicting the Water Demand Dynamic System Model Mapping Urban Crawling and Monitoring Using Remote Sensing Techniques and GIS
...Show More Authors

Publication Date
Tue Jun 01 2021
Journal Name
Iop Conference Series: Earth And Environmental Science
Adsorption of heavy metal ions using activated carbon derived from Eichhornia (water hyacinth)
...Show More Authors
Abstract<p>Removal of heavy metal ions such as, cadmium ion (Cd <sup>2+</sup>) and lead ion (Pb <sup>2+</sup>) from aqueous solution onto Eichhornia (water hyacinth) activated carbon (EAC) by physiochemical activation with potassium hydroxide (KOH) and carbon dioxide (CO<sub>2</sub>) as the activating agents were investigated. The Eichhornia activated carbon was characterized by Brunauer Emmett Teller (BET), Fourier Transform Infrared spectroscopy (FTIR), and Scanning Electron Microscopy (SEM) techniques. Whereas, the effect of adsorbent dosage, contact time of pH, and metal ion concentration on the adsorption process have been investigated using the batch process t</p> ... Show More
View Publication
Scopus (25)
Crossref (13)
Scopus Crossref
Publication Date
Mon Mar 30 2009
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
The Factors Affecting the Absorption of Ozone in Water
...Show More Authors

This study was concerned with using ozone gas in drinking water treatment plant at Ibn-Sina Company. The main purpose of this research is to find the best contactor for ozone unit proposed. An investigation was conducted to study the absorption of ozone by water in two type of absorber. The effects of the process variables (such as height of water column, contact time, and pH) on the amount of ozone absorbed were investigated. Box-Wilson central composite rotatable design is used to design the experimental work for the mentioned variables. It was found that the optimum value of the variables studied was:
i) Height of water column (90 cm)
ii) Contact time (17-18 min)
iii) PH (7 - 7.5)

View Publication Preview PDF
Publication Date
Tue Sep 01 2009
Journal Name
Al-khwarizmi Engineering Journal
Removal of Sulfate from Waste Water by Activated Carbon
...Show More Authors

Activated carbon was Produced from coconut shell and was used for removing sulfate from industrial waste water in batch Processes. The influence of various parameter were studied such as pH (4.5 – 9.) , agitation time (0 – 120)min and adsorbent dose (2 – 10) gm.

The Langmuir and frandlich adsorption capacity models were been investigated where showed there are fitting with langmmuir model with squre regression value ( 0.76). The percent of removal of  sulfate (22% - 38%) at (PH=7) in the isotherm experiment increased  with adsorbent mass increasing. The maximum removal value of sulfate at  different pH experiments is (43%) at pH=7.

View Publication Preview PDF
Publication Date
Sat Jan 01 2022
Journal Name
Aip Conference Proceedings
The best interpolation methods for evaluate water table pollution
...Show More Authors

View Publication
Scopus (2)
Scopus Crossref
Publication Date
Sat May 01 2021
Journal Name
Journal Of Physics: Conference Series
Performance application of ultraviolet disinfection technique for raw water
...Show More Authors
Abstract<p>Microbial water disinfection with UV rays is a universal technology. Disinfection is a method used to treat drinking water. This can be accomplished using physical and/or chemical processes. Physical Methods: Heating and UV rays are two main methods - UV rays to destroy cells and kill bacteria. The physical process generally gives drinking water an instant purification without producing harmful substances. However, there is no pollution in the water to ensure continuous cleaning. This study’s primary goal is to obtain environmentally safe drinking water in situations of water shortages and homes that lack clean water. Therefore, resort to appropriate home treatment. Therefore, an ex</p> ... Show More
View Publication
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Mon Jun 30 2003
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Interfacial Rheological Properties of Iraqi Crude Oils Water System
...Show More Authors

View Publication Preview PDF
Publication Date
Fri Jul 14 2017
Journal Name
Tenside Surfactant
Oil-Water Interfacial Tensions of Silica Nanoparticle-Surfactant Formulations
...Show More Authors

The implementation of nanotechnology in all industries is one of most significant research fields. Nanoparticles have shown a promising application in subsurface fields. On the other hand, various surfactants have been used in the oil industry to reduce oil/water interfacial tension and also widely used to stabilize the nano-suspensions. The primary objective of this study was to investigate the improvements of surfactants ability in term of interfacial tension (γ) reduction utilizing addition of silicon dioxide nanoparticles at different temperatures and salinity. The pendant drop technique has been used to measure γ and electrical conductivity has been used to measure the critical micelle concentration (CMC). The synergistic effects of

... Show More
Scopus (46)
Crossref (53)
Scopus Clarivate Crossref
Publication Date
Fri Jul 21 2023
Journal Name
Journal Of Engineering
Water Recovery from Brine Solution by Forward Osmosis Process
...Show More Authors

The present work aims to study the possibility of utilization a forward osmosis desalination process as an alternative method to extract water from brine solution rejected from reverse osmosis process.
Experiments conducted in a laboratory–scale forward osmosis (FO) unit in cross flow flat sheet membrane cell yielded water flux ranging from (0.0315 to 0.56 L/m2 .min) when using CTA membrane,and ranging from (0.419 to 2.785 L/m2 .min) for PA membrane under 0.4 bar. Two possible membrane orientations were tested. Sodium chloride with high concentrations was used as draw solution solute. The effect of membrane orientation on internal concentration polarization (ICP) was studied. Two regimes of ICP; dilutive and concentrative were desc

... Show More
View Publication Preview PDF
Crossref (5)
Crossref