Preferred Language
Articles
/
bsj-1314
Use of cefoxitin as indicator for detection of Methicillin Resistant Staphylococcus aureus
...Show More Authors

Rapid and accurate identification of Methicillin Resistant Staphylococcus aureus is essential in limiting the spread of this bacterium. The aim of study is the detection of Methicillin Resistant Staphylococcus aureus (MRSA) and determining their susceptibility to some antimicrobial agent. A total of fifty clinical Staphylococcus aureus, isolated from the nose of health work staff in surgery unit of Kalar general hospital and from ear of patients attended to the same hospital. The susceptibilities of isolates were determined by the disc diffusion method with oxacillin (1 ?g) and cefoxitin (30 ?g), and by the mannitol salt agar supplemented with cefoxitin (MSA-CFOX), susceptibilities of isolates to other antimicrobial agent were determined by standard disc diffusion method, Brain heart infusion (BHI) agar with vancomycin was used for detection of vancomycin resistant Staphylococcus aureus. out of fifty clinical isolates of Staphylococcus aureus 36/50(72%) considered to be MRSA according to MSA-CFOX growth and cefoxitin disc susceptibility results with critical diameter<27 mm but 35/50(68%) considered to be MRSA when critical diameter ?21 mm was depended, while according to oxacillin disc 29/50(58%) considered to be MRSA, all isolates showed good susceptibility to imipenem (100%) with different pattern of susceptibility to other antibiotics, 4/50(8%) showed non-susceptible to vancomycin and grew on BHI agar with supplemented vancomycin. high percentage of isolates were methicillin resistant and vancomycin reisitance occurs among them which may refer to irrational use of antimicrobial agent, thus, necessitate implementation of good strategies for control of infection and use of antibiotic. and to use of cefoxitin as screening agent for rapid detection of MRSA in microbiology laboratories.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Dec 17 2022
Journal Name
Iraqi Journal Of Laser
PDF Photodynamic effect of Rose Bengal activated by low-level laser light on S. aureus : Qusay K. Abbas*, Layla M. Hassan
...Show More Authors

Abstract: Background: Staphylococcus aureus is Gram-positive bacteria that lives as a normal flora in living organisms but can be pathogenic to humans. Although a relatively unspectacular, nonmotile coccoid bacterium, S. aureus is a dangerous human pathogen in both community-acquired and nosocomial infections. Due to the increasing emergence of new strains of this antibiotic-resistant bacteria, it has become essential to approach different methods to control this pathogen. One of these methods is the antimicrobial photodynamic inactivation process using a low-level laser, in this paper, the Photodynamic effects of Rose Bengal and LLLL on the virulence factors of S.aureus were evaluated.

... Show More
View Publication Preview PDF
Publication Date
Wed Jun 26 2019
Journal Name
Journal Of Mechanics Of Continua And Mathematical Sciences
VSM Based Models and Integration of Exact and Fuzzy Similarity For Improving Detection of External Textual Plagiarism admin June 29, 2019
...Show More Authors

View Publication
Clarivate Crossref
Publication Date
Tue Sep 30 2025
Journal Name
Gsc Advanced Research And Reviews
A comprehensive review of metal-organic framework based biosensors for detection of reactive oxygen species and hydrogen peroxide in biomedical applications
...Show More Authors

Metal-organic frameworks (MOFs) have emerged as revolutionary materials for developing advanced biosensors, especially for detecting reactive oxygen species (ROS) and hydrogen peroxide (H₂O₂) in biomedical applications. This comprehensive review explores the current state-of-the-art in MOF-based biosensors, covering fundamental principles, design strategies, performance features, and clinical uses. MOFs offer unique benefits, including exceptional porosity (up to 10,400 m²/g), tunable structures, biocompatibility, and natural enzyme-mimicking properties, making them ideal platforms for sensitive and selective detection of ROS and H₂O₂. Recent advances have shown significant improvements in detection capabilities, with limit

... Show More
View Publication
Crossref
Publication Date
Tue Mar 21 2023
Journal Name
Biomedical And Pharmacology Journal
Development and Validation of HPLC Method For the Detection of Fusidic Acid Loaded in Non-ionic and Cationic Nanoemulsion-Based Gels
...Show More Authors

Fusidic acid (FA) is a well-known pharmaceutical antibiotic used to treat dermal infections. This experiment aimed for developing a standardized HPLC protocol to determine the accurate concentration of fusidic acid in both non-ionic and cationic nano-emulsion based gels. For this purpose, a simple, precise, accurate approach was developed. A column with reversed-phase C18 (250 mm x 4.6 mm ID x 5 m) was utilized for the separation process. The main constituents of the HPLC mobile phase were composed of water: acetonitrile (1: 4); adjusted at pH 3.3. The flow rate was 1.0 mL/minute. The optimized wavelength was selected at 235 nm. This approach achieved strong linearity for alcoholic solutions of FA when loaded at a serial concentrati

... Show More
View Publication
Scopus (5)
Crossref (3)
Scopus Crossref
Publication Date
Sat Dec 01 2018
Journal Name
Applied Soft Computing
A new evolutionary algorithm with locally assisted heuristic for complex detection in protein interaction networks
...Show More Authors

View Publication
Scopus (15)
Crossref (9)
Scopus Clarivate Crossref
Publication Date
Mon Sep 01 2025
Journal Name
Journal Of Cancer Research Updates
Hematological Parameters in Liver Metastasis: A Comprehensive Clinical Evaluation for Early Detection in Iraqi Patients
...Show More Authors

Background: Liver metastasis significantly complicates cancer prognosis, yet easily accessible markers for its early detection and monitoring remain crucial. This study aimed to comprehensively evaluate key hematological parameters as potential indicators for liver metastasis in Iraqi patients. Methods: We conducted a cross-sectional study comparing hematological profiles between 90 patients (presumably with liver metastasis) and 30 healthy controls. White Blood Cell (WBC) count, Lymphocyte percentage, Neutrophil percentage, and Neutrophil-to-Lymphocyte Ratio (NLR) were analyzed. Given non-normal data distributions (confirmed by the Shapiro-Wilk test), group comparisons were performed using the non-parametric Mann-Whitney U test.

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Sun Jul 01 2012
Journal Name
2012 International Symposium On Innovations In Intelligent Systems And Applications
Edge detection for fast block-matching motion estimation to enhance Mean Predictive Block Matching algorithm
...Show More Authors

View Publication
Scopus (5)
Crossref (3)
Scopus Crossref
Publication Date
Sun Sep 03 2017
Journal Name
Baghdad Science Journal
Gravity Field Interpretation for Major Fault Depth Detection in a Region Located SW- Qa’im / Iraq
...Show More Authors

This research deals with the qualitative and quantitative interpretation of Bouguer gravity anomaly data for a region located to the SW of Qa’im City within Anbar province by using 2D- mapping methods. The gravity residual field obtained graphically by subtracting the Regional Gravity values from the values of the total Bouguer anomaly. The residual gravity field processed in order to reduce noise by applying the gradient operator and 1st directional derivatives filtering. This was helpful in assigning the locations of sudden variation in Gravity values. Such variations may be produced by subsurface faults, fractures, cavities or subsurface facies lateral variations limits. A major fault was predicted to extend with the direction NE-

... Show More
View Publication Preview PDF
Scopus (8)
Crossref (2)
Scopus Crossref
Publication Date
Fri Dec 01 2023
Journal Name
Iraqi Journal Of Physics
Surface Plasmon Resonance (SPR)-Based Multimode Optical Fiber Sensors for Electrical Transformer Oil Aging Detection
...Show More Authors

I

In this study, optical fibers were designed and implemented as a chemical sensor based on surface plasmon resonance (SPR) to estimate the age of the oil used in electrical transformers. The study depends on the refractive indices of the oil. The sensor was created by embedding the center portion of the optical fiber in a resin block, followed by polishing, and tapering to create the optical fiber sensor. The tapering time was 50 min. The multi-mode optical fiber was coated with 60 nm thickness gold metal. The deposition length was 4 cm. The sensor's resonance wavelength was 415 nm. The primary sensor parameters were calculated, including sensitivity (6.25), signal-to-noise ratio (2.38), figure of merit (4.88), and accuracy (3.2)

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Feb 10 2019
Journal Name
Iraqi Journal Of Physics
A nonlinear edge –preserving smoothing filter for edge detection on color and gray satellite images
...Show More Authors

A nonlinear filter for smoothing color and gray images
corrupted by Gaussian noise is presented in this paper. The proposed
filter designed to reduce the noise in the R,G, and B bands of the
color images and preserving the edges. This filter applied in order to
prepare images for further processing such as edge detection and
image segmentation.
The results of computer simulations show that the proposed
filter gave satisfactory results when compared with the results of
conventional filters such as Gaussian low pass filter and median filter
by using Cross Correlation Coefficient (ccc) criteria.

View Publication Preview PDF
Crossref