In this work a flowsheet has been put for the recovery of uranium and plutonium from 2.5M nitric acid solutions using 17.5% tributyl phosphate (TBP) and 2.5% trioctylamine (TOA) in kerosene diluent . The fission products (resulting from irradiated of uranium samples in nuclear research reactor) were removed from the desired actinides U & Pu .The organic phase TBP/TOA/Kerosene, containing both actinides U&Pu were stripped using 0.1 M HNO3. Trioctylamine (2.5 volume ratio ) in mesitylene , has been used in conditions appropriate for the recovery of Pu . From the experiments done using mixer- settler , the concentration of uranium in the organic phase in such conditions was very low ,not exceeding parts of a million .
In this work, calcium ions were determined by the addition to the allyl chloride monomer resulting from bulk polymerization formation. To acquire the highest adsorption capacity, molar ratios of the template, monomer, and cross-linking agent, as well as solvents and multiple monomers were investigated. Scanning Electron Microscopy (SEM) and Fourier Transform Infrared Spectroscopy (FTIR) were used to analyze the calcium ion polymer. The elution of calcium had a small effect on the surfaces of the three-dimensional network structure. Calcium (II) ions were successfully eluted using a mixture of methanol and acetic acid. The calcium adsorption capacities were 3.8145 and 9.01773 mol/g (Qmax), respectively. A Langmuir isot
... Show MoreThe removal of heavy metal ions from wastewater by ion exchange resins ( zeolite and purolite C105), was investigated. The adsorption process, which is pH dependent, shows maximum removal of metal ions at pH 6 and 7 for zeolite and purolite C105 for initial metal ion
concentrations of 50-250 mg/l, with resin dose of 0.25-3 g. The maximum ion exchange capacity was found to be 9.74, 9.23 and 9.71 mg/g for Cu2+, Pb2+, and Ni2+ on zeolite respectively, while on purolite C105 the maximum ion exchange capacity was found to be 9.64 ,8.73 and 9.39 for Cu2+, Pb2+, and Ni2+ respectively. The maximum removal was 97-98% for Cu2+ and Ni2+ and 92- 93% for Pb2+ on zeolite, while it was 93-94% for Cu2+, 96-97% for Ni2+, and 87-88% for Pb2+ on puroli
The LiCoMnO4 spinel compound was prepared by a sol–gel method. Structural measurements were utilized to investigate the characteristics of LCMO powder. The powder crystallizes in the space group Rd-3m, with a trigonal crystallinity structure, according to XRD analysis (hexagonal axes). SEM images showed that the crystalline grains sizes were about 200 nm - 350 nm, which provides large surface area. The sample had soft magnetic characteristics, according to hysteresis behaviour analysis in the Vibrating Sample Magnetometer (VSM). The prepared material is thought to be a candidate for the applications of energy storage in lithium-ion batteries.
A simulated ion/electron optical transport and focusing system has been put forward to
be mounted on high voltage transmission electron microscope for in situ investigations.
The suggested system consists of three axially symmetric electrostatic lenses namely an
einzel lens, an accelerating immersion lens, and a decelerating immersion lens, in addition
to an electrostatic quadrupole doublet lens placed on the image side. The electrodes
profile of these lenses is determined from the proposed axial field distributions. The
optical properties of the whole system have been computed together with the trajectory of
the accelerated charged-particles beam along the optical axis of the system. The computed
dimensions of th
Background: The ideal force-delivery system must: provide optimal tooth moving forces that elicit the desired effects, be comfortable and hygienic for the patient, require minimal operator manipulation and patient cooperation and provide rapid tooth movement with minimal mobility during orthodontic therapy, the elastomeric chains have the greatest potential to fulfill these requirements. Materials and Methods: This in vitro study was designed to determine the effect of three different mechanisms for canine retraction : (6-3 , 6-5-3 and chain loop ) on the load relaxation behavior of three types of elastomeric chains : (maximum clear , maximum silver and extreme silver) from the same company (Ortho Technology company) with two different bran
... Show MoreThe aim of this work is to determine the uranium concentration in soil samples
taken from the north, south, east, west and center of the city of Baghdad and
measure its impact on the rate of cell division for non-smokers peoples and living in
those areas and that between the ages 25-30 year.
The uranium concentration in the samples determined by using CR-39 track
detector . As calculated for the ten samples of each site when irradiated by thermal
neutrons from the (Am - Be) source with flux (5x 103 n S-1cm-2), the concentration
values were calculated by a comparison with standard geological samples. The
results indicate that the extent of the concentration of uranium in the soil north and
east of Baghdad was 12
Radon and its daughters are of the natural radioactive decay of the uranium series. Exposure to radon gas leads to lung cancer, so the risks are significantly higher for smokers than for non-smokers. Therefore, the risk of radon increases for both active and passive smokers. The radioactivity of alpha particles emitted by radium 226, the main source of radon 222, has become harmful because its prevalence and inhalation increase with increased smoking. In this study, a CR-39 detector was used to measure radon, radium, and uranium concentrations and then calculate risk parameters in seven cigarette-smoking females in vitro study of human blood samples, and three normal females with no actual and passive cigarette smoking. The rado
... Show MoreA simple, rapid, accurate and sensitive spectrophotometric method is proposed for the detennination of chlorprQm<tZine -HCl in pwe form and in pharmaceutical formulation. This method is based on the formation. of ion assodation complexes of dmg with either thymol
blue or bromophenol blue in an acidic buffer at pH values 4.17 and
3.68, respectively.
The ion-pair complexes formed exhibit absorption maxima at 41 Onm for both thymol blue and bromophenol blue. These complexes· are quantitatively extracted &n
... Show MoreA selective and sensitive spectrophotometric extraction method was established and used to estimate antihypertensive drug, losartan potassium. The method is based on the formation of blue ion pair of the anionic drug, losartan, and the cationic dye, methylene blue, at adjusted pH 6.5 in aqueous solutions, followed by quantitative extraction to dichloromethane;.The observed maximum absorbance was at π 654.9 nm. With 4.53321 x 105 M-1 cm-1 molar absorptivity, Beer's law was obeyed within a concentration range of 0.03-1.5 μg / ml. The limit of detection and the limit of quantification were 0.01μg / ml and 0.03μg / ml, respectively. The method's precision was estimated by a relative standard devi
... Show More