Preferred Language
Articles
/
bsj-1287
Determination of bacterial contamination of milk using fluorometry
...Show More Authors

The aim of this paper is to determine the feasibility of using fluorometric methods as an indicator for quality and contamination of milk with E.coli bacteria, and selection the suitable wavelength to be used with laser induced auto fluorescence. Three groups of milk samples were used in this study: Fresh pasteurized milk samples, milk samples containing different concentration of E.coli bacteria which were added artificially, and milk samples that were kept in refrigerator for 3-5 days. Thirteen excitation wavelengths were used to get the emission spectra for all milk samples using spectroflourometer .The results showed that the emission spectra at 275nm excitation wavelength gave a good differentiation between these three groups. The data analysis demonstrated that the proposed method can bring progress in identification of milk quality and contamination with rapidness, high sensitivity and low cost diagnostic tool. Laser light at this wavelength that transmitted by optical fiber can be used for milk samples examination in situe and for more precise results.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Jul 01 2024
Journal Name
Journal Of Food Process Engineering
Artificial intelligence‐based modeling of novel non‐thermal milk pasteurization to achieve desirable color and predict quality parameters during storage
...Show More Authors
Abstract<sec><label></label><p>This study proposed using color components as artificial intelligence (AI) input to predict milk moisture and fat contents. In this sense, an adaptive neuro‐fuzzy inference system (ANFIS) was applied to milk processed by moderate electrical field‐based non‐thermal (NP) and conventional pasteurization (CP). The differences between predicted and experimental data were not significant (<italic>p</italic> > 0.05) for lightness (<italic>L</italic>*), redness‐greenness (<italic>a</italic>*), yellowness‐blueness (<italic>b</italic>*), total color differences (∆<italic>E</italic>), hue angle (<italic>h</italic></p></sec> ... Show More
View Publication
Scopus (8)
Crossref (7)
Scopus Clarivate Crossref
Publication Date
Sun Mar 07 2010
Journal Name
Baghdad Science Journal
Determination the concentration for uranium in phosphrous fertilizers by using nuclear track detector CR-39
...Show More Authors

The aim of this research was to study the concentrations of Uranium in the phosphorus fertilizers using Nuclear track detector (CR-39). Our present investigation is based on the study of 10 types samples for different kinds of phosphorus fertilizers which were available in the local market Some of them were Iraqi made and the others from different countries like, (Iran, Italy, Holland, Lebanon and Jordan) .. The result obtained shows that the Uranium concentration in phosphorus fertilizers samples varies from (3.59ppm) to(2.59ppm). Based on the radioactive concentration of Uranium in the samples all the results obtained between(3.59ppm) in the Iraqi super phosphate to (2.59ppm) in the mixture Iraqi phosphate fertilizer are withi

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Aug 12 2024
Journal Name
Al-rafidain J Med Sci
Identifying Clinical and Biochemical Predictors of Seizures in Children with Acute Bacterial Meningitis: Insights from a Cross-Sectional Study
...Show More Authors

Background: The occurrence of seizures in bacterial meningitis is important, as it has been reported to increase the risk of complications; however, its frequency and predictors are not well studied yet. Objective: To assess the frequency, clinical, and biochemical predictors of seizures in children with acute bacterial meningitis. Method: A cross-sectional study recruited confirmed acute bacterial meningitis cases based on positive CSF culture and sensitivity among children aged 2 months to 15 years admitted to the Central Child Teaching Hospital emergency department in Iraq. Patients were divided into two groups based on seizure at presentation time. Demographic characteristics [age, gender, residence, duration of fever and disease, prese

... Show More
Preview PDF
Scopus (1)
Scopus
Publication Date
Fri Jan 01 2021
Journal Name
Systematic Reviews In Pharmacy
A COMPARATIVE STUDY OF CHEMICAL COMPOUNDS AND ANTI-BACTERIAL EFFICACY OF DIFFERENT ALLIUM CEPA PLANT EXTRACTS
...Show More Authors

Publication Date
Mon Feb 03 2025
Journal Name
Nanomaterials
Impact of Silver and Copper Oxide Nanoparticles on Anaerobic Digestion of Sludge and Bacterial Community Structure
...Show More Authors

The effect of metal nanoparticles on the anaerobic digestion of sludge and the sludge bacterial community are still not well-understood, and both improvements and inhibitions have been reported. This study investigated the impact of 2, 10, and 30 mg/g TS silver and copper oxide nanoparticles (AgNPs and CuONPs) on the mesophilic anaerobic digestion of sludge and the bacterial community structure. The reactors were monitored for changes in tCOD, sCOD, TS, VS, biogas generation, and cell viability. Also, the relative abundance and taxonomic distribution of the bacterial communities were analyzed at the phylum and genus levels, including the genera involved in anaerobic digestion. Both AgNPs and CuONPs exhibited some inhibition on anaer

... Show More
View Publication
Scopus (6)
Crossref (6)
Scopus Clarivate Crossref
Publication Date
Sun Mar 01 2015
Journal Name
Baghdad Science Journal
A New method for ISE construction for methyl orange dyes and using for indirect determination of Amitriptyline Hydrochloried drug
...Show More Authors

A new method for construction ion-selective electrode (ISE) by heating reaction of methyl orange with ammonium reineckate using PVC as plasticizer for determination methyl orange and determination Amitriptyline Hydrochloried drug by formation ion-pair on electrode surface . The characteristics of the electrode and it response as following : internal solution 10-4M , pH (2.5-5) ,temperature (20-30) and response time 2 sec. Calibration response for methyl orange over the concentrationrange 10-3 -10-9 M with R=0.9989 , RSD%=0.1052, D.O.L=0.315X10-9 MEre%=(-0.877- -2.76) , Rec%.=(97.230 -101.711) .

View Publication Preview PDF
Crossref
Publication Date
Sun Aug 01 2021
Journal Name
Sensors And Actuators B: Chemical
Sensitive and simple colorimetric methods for visual detection and quantitative determination of semicarbazide in flour products using colorimetric reagents
...Show More Authors

After baking the flour, azodicarbonamide, an approved food additive, can be converted into carcinogenic semicarbazide hydrochloride (SEM) and biurea in flour products. Thus, determine SEM in commercial bread products is become mandatory and need to be performed. Therefore, two accurate, precision, simple and economics colorimetric methods have been developed for the visual detection and quantitative determination of SEM in commercial flour products. The 1st method is based on the formation of a blue-coloured product with λmax at 690 nm as a result of a reaction between the SEM and potassium ferrocyanide in an acidic medium (pH 6.0). In the 2nd method, a brownish-green colored product is formed due to the reaction between the SEM and phosph

... Show More
View Publication
Crossref (27)
Crossref
Publication Date
Tue Apr 10 2018
Journal Name
Ibn Al-haitham Jour. For Pure & Appl. Sci.
Effect of Scan Rate and pH on Determination Amoxilline Using Screen Printed Carbon Electrode Modified with Functionalized Graphene Oxide
...Show More Authors

Graphene oxide GO was functionalized with 4-amino, 3-substituted 1H, 1, 2, 4 Triazole 5(4H) thion (ASTT) to obtain GOT. GOT characterized by FT-IR, XRD.via modification of the working electrode of the SPCE with the prepared nanomaterial (GOT) the effect of scan rate and pH on the determination of Amoxilline (AMOX) was studied using cyclic voltammetry. AMOX show various responses at pH ranging from 2 to 7 and also was observed sharp increase in the oxidation peaks in the pH 3. The formal potential (midpoint) for AMOX was highly pH-dependent. From the effect of scan rate, surface coverage concentration Γ of electroactive species the values of the electron transfer coefficient and the electron transfer constant rate ket was obtained as 5.39×

... Show More
Preview PDF
Publication Date
Wed Mar 01 2023
Journal Name
Journal Of Applied Spectroscopy
Spectrophotometric Method for the Determination of Naphazoline Nitrate in Bulk and Pharmaceutical Preparations by Using 1,2-Naphthoquinone-4-Sulfonate
...Show More Authors

A simple, accurate, and cost-efficient UV-Visible spectrophotometric method has been developed for the determination of naphazoline nitrate (NPZ) in pure and pharmaceutical formulations. The suggested method was based on the nucleophilic substitution reaction of NPZ with 1,2-naphthoquinone-4-sulfonate sodium salt in alkaline medium at 80°C to form an orange/red-colored product of maximum absorption (λmax) at 483 nm. The stoichiometry of the reaction was determined via Job's method and limiting logarithmic method, and the mechanism of the reaction was postulated. Under the optimal conditions of the reaction, Beerʼs law was obeyed within the concentration range 0.5–50 μg/mL, the molar absorptivity value (ε) was 5766.5 L × mol–1 × c

... Show More
Scopus (1)
Scopus
Publication Date
Sun Aug 01 2021
Journal Name
Eurasian Chemical Communications
New sensitive turbidimetric method for determination of losartan potassium in pharmaceutical formulations using flow injection combined with homemade turbidimeter
...Show More Authors

Scopus