Preferred Language
Articles
/
bsj-1284
Evaluation of Transfected HEP-2 Cell Line Using ß-Galactosidase Reporter Assay System
...Show More Authors

Liposome-mediated transfection of cancer cells provide a valuable experimental technique to study cellular gene expression and may also be adapted for gene therapy studies. However, the widely recognized advantage of liposome-mediated transfection is high efficiency. Therefore, this study were performed to optimize transfection techniques in human larynx carcinoma cell line Hep-2 using the commercial synthetic lipid TransFast™ Reagent and monitoring the expression efficiency by using the pSV-?-galactosidase Control Vector which encoded ?-galactosidase, maximum transfection efficiency were achieved with TransFast™ Reagent used at the Charge ratios of 2:1 and 0.5 µg DNA/ml, this is indicate that TransFast™ Reagent can be used as an efficient transfection agent to deliver foreign DNA into human larynx carcinoma cell line Hep-2 and expression of the transgene efficiently.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Feb 01 2024
Journal Name
Baghdad Science Journal
A New Green Approach of CFIA Technique for Direct Assay with a High Throughput of Sulfamethoxazole Drugs Using Condensation Reaction with NQS Agent
...Show More Authors

A new design of manifold flow injection (FI) coupling with a merging zone technique was studied for sulfamethoxazole determination spectrophotometrically. The semiautomated FI method has many advantages such as being fast, simple, highly accurate, economical with high throughput . The suggested method based on the production of the orange- colored compound of SMZ with (NQS)1,2-Naphthoquinone-4-Sulphonic acid Sodium salt in alkaline media NaOH at λmax 496nm.The linearity range of sulfamethoxazole was  3-100  μg. mL-1, with (LOD) was 0.593 μg. mL-1 and the RSD% is about 1.25 and the recovery is 100.73%. All various physical and chemical parameters that have an effect on the stability and development of

... Show More
View Publication Preview PDF
Scopus (2)
Scopus Crossref
Publication Date
Fri Jan 01 2016
Journal Name
Der Pharmacia Lettre
Synthesis, characterization and anticonvulsant evaluation of new derivatives derived from 5-methoxy-2-mercapto benzimidazole
...Show More Authors

A new series of 5-methoxy-2-mercapto benzimidazole derivatives were synthesized by the reaction of 5-methoxy- 2-mercaptobenzimidazole with chloroacetic acid and affords 2-((5-methoxy-1H-benzo[d]imidazol-2-yl)thio) acetic acid (1),which on cyclization with acetic anhydride and pyridine gives 7- methoxybenzo[4,5]imidazo[2,1-b]thiazol- 3(2H)-one(2), which on condensation with different aryl aldehydes in the presence of anhydrous sodium acetate in glacial acetic acid, furnishes a arylidene thiazolidinone. The purity of the synthesized compounds was confirmed by melting point and TLC.The structures were established by different spectral analysis such as FTIR,1HNMR, and CHN analysis. The newly synthesized compounds (3a-d) were in vivo evaluated f

... Show More
View Publication Preview PDF
Scopus (3)
Scopus
Publication Date
Wed Mar 29 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Preparation and Evaluation of Atenolol Floating Beads as a Controlled Delivery System
...Show More Authors

         This study aims to encapsulate atenolol within floating alginate-ethylcellulose beads as an oral controlled-release delivery system using aqueous colloidal polymer dispersion (ACPD) method.To optimize drug entrapment efficiency and dissolution behavior of the prepared beads, different parameters of drug: polymer ratio, polymer mixture ratio, and gelling agent concentration were involved.The prepared beads were investigated with respect to their buoyancy, encapsulation efficiency, and dissolution behavior in the media: 0.1 N HCl (pH 1.2), acetate buffer (pH 4.6) and phosphate buffer (pH 6.8). The release kinetics and mechanism of the drug from the prepared beads was investigated.All prepare

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Mar 29 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences
Preparation and Evaluation of Atenolol Floating Beads as a Controlled Delivery System
...Show More Authors

         This study aims to encapsulate atenolol within floating alginate-ethylcellulose beads as an oral controlled-release delivery system using aqueous colloidal polymer dispersion (ACPD) method.To optimize drug entrapment efficiency and dissolution behavior of the prepared beads, different parameters of drug: polymer ratio, polymer mixture ratio, and gelling agent concentration were involved.The prepared beads were investigated with respect to their buoyancy, encapsulation efficiency, and dissolution behavior in the media: 0.1 N HCl (pH 1.2), acetate buffer (pH 4.6) and phosphate buffer (pH 6.8). The release kinetics and mechanism of the drug from the prepared beads was investigated.All prepared atenolol beads remained f

... Show More
Preview PDF
Crossref
Publication Date
Tue Jun 09 2020
Journal Name
Article In Journal Of Engineering Science And Technology
English Numbers Recognition Based on Sign Language Using Line-Slope Features and PSO-DBN Optimization Method
...Show More Authors

View Publication
Scopus (2)
Scopus
Publication Date
Sun Nov 10 2019
Journal Name
Journal Of Engineering And Applied Sciences
Fabrication and Properties of Ag<sub>2</sub>O/Si Heterojunction Solar Cell Pure and Doped (Sb, Sn and Se)
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Sun Oct 22 2023
Journal Name
Iraqi Journal Of Science
New Mode for the On-Line Determination of Amiloride in Pure and Pharmaceutical Preparation Using CFIA Via the Use of Linear Array from Six LED (Snow White) with One Solar Cell in a Homemade Ayah 6Sx1-T-1D Solar CFI Analyser
...Show More Authors

A newly flow injection-turbidimetric method characterized by it is speed and sensitivity has been developed for the determination of Amiloride in pure and pharmaceutical preparations. It is based on the formation of yellowish white precipitate for the Amiloride-phosphomolybidic acid ion pair in aqueous medium. Turbidity was measured by Ayah 6Sx1-T-1D solar cell CFI analyser via the attenuation of incident light from the surfaces precipitated particles at 0-180. The Chemical and physical parameters were investigated. Linear dynamic range for the attenuation of incident light versus Amiloride concentration was of 0.005-10 mmol.L-1, with the correlation coefficient (r) of 0.9986 , while the percentage linearity (r2%) was 99.71%. The L.O.

... Show More
View Publication Preview PDF
Publication Date
Sun Jul 02 2023
Journal Name
Iraqi Journal Of Science
New Mode for the On-Line Determination of Amiloride in Pure and Pharmaceutical Preparation Using CFIA Via the Use of Linear Array from Six LED (Snow White) with One Solar Cell in a Homemade Ayah 6Sx1-T-1D Solar CFI Analyser
...Show More Authors

A newly flow injection-turbidimetric method characterized by it is speed and sensitivity has been developed for the determination of Amiloride in pure and pharmaceutical preparations. It is based on the formation of yellowish white precipitate for the Amiloride-phosphomolybidic acid ion pair in aqueous medium. Turbidity was measured by Ayah 6Sx1-T-1D solar cell CFI analyser via the attenuation of incident light from the surfaces precipitated particles at 0-180. The Chemical and physical parameters were investigated. Linear dynamic range for the attenuation of incident light versus Amiloride concentration was of 0.005-10 mmol.L-1, with the correlation coefficient (r) of 0.9986 , while the percentage linearity (r2%) was 99.71%. The L.O.

... Show More
View Publication Preview PDF
Publication Date
Sun Jan 01 2023
Journal Name
Iraqi Journal Of Hematology
Evaluation of angiopoietin-2 level in patients with multiple myeloma at presentation and in remission state
...Show More Authors

The study aimed to assess the level of ANG‑2 in MM patients at diagnosis and in remission state and elaborate on its correlation with interleukin‑6 (IL‑6) and beta‑2 microglobulin (B2M) levels. Sixty MM patients; 20 newly diagnosed (ND), and 40 patients in remission were included. Twenty healthy individuals were included as a control group. Plasma levels of ANG‑2, B2M, and IL‑6 were tested by enzyme‑lin ked immunosorbent assay. There are significant statistical differences between ND patients and those in remission in hemoglobin, neutrophil count, blood urea, serum creatinine, glomerular filtration rate, B2M, IL6, and ANG‑2 (P = 0.001, 0.033, 0.005, 0.001, 0.001, 0.001, 0.004, and 0.001, respectively). ANG‑2 showed signifi

... Show More
View Publication
Clarivate Crossref
Publication Date
Thu Dec 01 2016
Journal Name
2016 Asia-pacific Microwave Conference (apmc)
High selectivity microstrip bandpass filter using feedback CRLH-TL unit cell
...Show More Authors

View Publication
Scopus Crossref