ZnS thin films were grown onto glass substrates by flash evaporation technique, the effects of ? – rays on the optical constants of ZnS these films were studied. It was found that ? – rays affected all the parameters under investigation.
Films of pure Poly (methyl methacrylate) (PMMA) doped by potassium iodide (KI) salt with percentages (1%) at different thickness prepared by casting method at room temperature. In order to study the effect of increasing thickness on optical properties, transmission and absorption spectra have been record for five different thicknesses(80,140,210,250,320)µm. The study has been extended to include the changes in the band gap energies, refractive index, extinction coefficient and absorption coefficient with thickness.
The change in the optical properties for samples of pure PVA and PVA /K2CrO4composite have been studied .The samples were prepared with different percentage (1,3,5,and 7)%wt of K2CrO4 by casting method technique .In this work ,we are study the absorption ,reflectance spectra ,absorption coefficient, energy gap ,extinction coefficient ,and transmittance spectra as a function of wavelength range (200-800)nm ,Also real and imaginary part of dielectric constant have been studied in the range of wave length .The results exhibit the optical properties change by the increase of K2CrO4 concentration, and the values of energy gap for indirect transitions decrease by the increase of the concentration of K2CrO4
... Show MoreEricson’s formula describes the partial level density (PLD) of pre-equilibrium reactions and corrections. PLD with pairing correction can be calculated using four methods, namely, pairing, improved pairing, exact Pauli and back shift energy corrections. The variations in the PLD values of each of the four formulas of strontium (88Sr), Yttrium (89Y) and Zirconium (90Zr) isotones have been examined. Results shows that the PLD values that use pairing and improved pairing corrections do not vary for different isotones. However, a small change in PLD values is observed when exact Pauli correction and back shift energy were utilised. The change in the PLD values using back shift energy correction is bigg
... Show MoreIron–phthalocyanine (FePc) organic photoconductive detector was fabricated using pulsed laser deposition (PLD) technique to work in ultraviolet (UV) and visible regions. The organic semiconductor material (iron phthalocyanine) was deposited on n-type silicon wafer (Si) substrates at different thicknesses (100, 200 and 300) nm. FePc organic photoconductive detector has been improved by two methods: the first is to manufacture the detector on PSi substrates, and the second is by coating the detector with polyamide–nylon polymer to enhance the photoconductivity of the FePc detector. The current–voltage (I–V) characteristics, responsivity, photocurrent gain, response time and the quantum efficiency of the fabricated photoconduc
... Show MoreIn this study, the potential combined effects of silver (AgNPs) and silicon dioxide nanoparticles (SiO2NPs) on male albino mice which were exposed intraperitoneally to the 50 mg/kg and 100 mg/kg and mixed concentrations of nanoparticles (NPs) for periods of 2 and 4 weeks, were evaluated. The evaluation was performed by examining the haematological and biochemical parameters, in addition to the bioaccumulation of NPs in the liver and kidney. The results showed that the platelets count significantly increased in all exposed groups, while red blood cell count (RBCs) decreased in most exposed groups. White blood cells (WBCs) and haemoglobin (Hb) showed different levels in the exposed groups. Serum aspartate aminotransfera
... Show MoreTwelve storm dust samples were collected from three cities in Iraq. The samples were collected in the same time during big storms which hit Iraq in summer, 2012 and 2013. The deposited dust on 4 by 4 nylon sheet on surfaces of selected buildings in cities of Baghdad, Fallujah and Al-Ramadi were collected. Each sample was put in sealed Marinilli beaker and kept for 4 weeks to reach the equilibrium state between radium and its short half-life daughters. Gamma spectrometry system based on HPGe was used for analysis of natural and artificial radionuclides in the dust. The activities of natural radionuclides were found to be ranged between 13-19 Bq/kg, 9-14 Bq/kg and 200-240 Bq/kg for Ra-226, Th-232 and K-40 respectively, while Cs-137 w
... Show MoreSteps were taken to obtain the Kojic acid crystals from local fungal isolation A. flavus WJF81 by separating the fermentation products from the fungus mycelium from the production plant at the centrifuge at a speed of 5000 cycles for 10 minutes. The extraction was followed by ethyl acetate then supernatant concentrate by using rotary evaporator, and dried with heat oven 37ºC. Long, yellowish, pristine acid crystals were obtained that examined the optical microscope with a magnification force of 10x and 40x. The melting point of kojic acid was determined between 152.9-153.5 °C Results of the diagnosis of Kojic acid by applying High pressure liquid chromatography HPLC technique showed that the acid was at one peak, which was close to the
... Show MoreThis study explored the preservative effects of the alcoholic leaves’ extract of Ficus carica plant on beef refrigerated for 15 days. Phytochemical analysis showed that the plant extract contained terpenoids, flavonoids, tannins, saponins, and alkaloids. Furthermore, the alcoholic extract of plants significantly reduced the total viable counts of psychrotrophic bacteria, pathogenic bacteria (Proteus, Salmonella typhimiurum, Escherichia coli, and Staphylococcus aureus), and yeasts (Candida kruse, Candida lambica, and Zygosaccharomyces) isolated from meat samples, particularly at 100 and 200 mg/ml concentrations.
The antioxidant activity of the extract was det
... Show MoreThe present study develops the sorption model for simulating the effects of pH and temperature on the uptake of cadmium from contaminated water using waste foundry sand (WFS) by allowing the variation of the maximum adsorption capacity and affinity constant. The presence of two acidic functional groups with the same or different affinity is the basis in the derivation of the two models; Model 1 and Model 2 respectively. The developed Bi-Langmuir model with different affinity (Model 2) has a remarkable ability in the description of process under consideration with coefficient of determination > 0.9838 and sum of squared error < 0.08514. This result is proved by FTIR test where the weak acids responsible of cadmium ions removal
... Show More