The buildup factor of cylindrical samples (shields) for Brass, Copper & lead (Brass, Cu, Pb (was studied, where buildup factor were calculated with thickness between (0-12) m.f.p. for Co60 and Cs137sources with activities (30) & (41) MBq respectively , using scintillation detector NaI(T?) with (3"×3")volume .The results shows increases of buildup factor for low atomic number(Z) samples where the energy of radiation source was constant, also shows increases of buildup factor with decreases the energy of radiation source. An empirical equation was obtained using Matlab7 program this equation have agreements with most obtained data for 96%.
The present study aimed to assess the potential impact of serum concentration of undercarboxylated osteocalcin (the active form of osteocalcin) and fibroblast growth factor-23 on the incidence of cardiovascular diseases in type 2 diabetics with carotid artery calcification and the possible association with metabolic changes in relation to glucose and minerals homeostasis.
This study included 52 men with carotid artery calcification type 2 diabetes mellitus. These patients were categorized; as follows: group A includes 30 patients who had cardiovascular disease and group B includes 22 patients who had no cardiovascular disease. These groups were compared with 25 apparently healthy control (Group C).
It has been shown
... Show Moreinsulin-like Growth Factor 1 (IGF-1) gene has been described in several studies as a candidate gene for growth. The present study attempts to identify associations between body weight traits and polymorphisms at 279 position of 5'UTR flanking region of IGF-1 gene in broiler chickens. Three hundred broiler chickens from two breeds (Cobb 500 and Hubbard F-15) were used in this study. A single nucleotide polymorphism (SNP) at 279 position of 5'UTR region of the IGF-1 gene was identified in 20.6 and 60.3% of Cobb 500 and Hubbard F-15, respectively, using the PCR-RFLP technique. Allele frequencies were 83.87 and 42.80% for the T allele and 16.13 and 57.20% for the C allele in Cobb500 and Hubbard-15 breeds, respectively. Genotype frequencies were
... Show MoreIn the present study, activated carbon supported metal oxides was prepared for thiophene removal from model fuel (Thiophene in n-hexane) using adsorptive desulfurization technique. Commercial activated carbon was loaded individually with copper oxide in the form of Cu2O/AC. A comparison of the kinetic and isotherm models of the sorption of thiophene from model fuel was made at different operating conditions including adsorbent dose, initial thiophene concentration and contact time. Various adsorption rate constants and isotherm parameters were calculated. Results indicated that the desulfurization was enhanced when copper was loaded onto activated carbon surface. The highest desulfurization percent for Cu2O/AC and o
... Show MoreIn this study, a new adsorbent derived from sunflower husk powder and coated in CuO nanoparticles (CSFH) was investigated to evaluate the simultaneous adsorption of Levofloxacin (LEV), Meropenem (MER), and Tetracycline (TEC) from an aqueous solution. Significant improvements in the adsorption capacity of the sunflower husk were identified after the powder particles had been coated in CuO nanoparticles. Kinetic data were correlated using a pseudo-second-order model, and was successful for the three antibiotics. Moreover, high compatibility was identified between the LEV, MER, and TEC, isotherm data, and the Langmuir model, which produced a better fit to suit the isotherm curves. In addition, the spontaneous and exothermic nature of the adsor
... Show MoreSpectrophotometric method was developed for the determination of copper(II) ion. Synthesized (2,2[O-Tolidine-4,4-bis azo]bis[4,5-diphenyl imidazole]) (MBBAI) was used as chromogenic reagent at pH=5. Various factors affecting complex formation, such as, pH effect, reagent concentration, time effect and temperature effect, have been considered and studied. Under optimum conditions concentration ranged from (5.00-80.00) µg/mL of copper(II) obeyed Beer`s Low. Maximum absorption of the complex was 409nm with molar absorpitivity 0.127x104 L mol-1 cm-1. Limit of detection(LOD) and Limit of quantification were 1.924 and 6.42 μg/mL, respectively.
... Show More