Preferred Language
Articles
/
bsj-1064
The effect of wastewater disposal on the water quality and phytoplankton in Erbil wastewater channel.
...Show More Authors

In this study, phytoplankton density, chlorophyll-a, and selected physico- chemical parameters were investigated in Erbil wastewater channel. The surveys were carried out monthly from May 2003 to April 2004. Samplings were established on three sites from headwaters to the mouth. The results showed that pH was in alkaline side of neutrality, with significant differences (P<0.05) between sites 1 and 3. TSS concentration decreased from site 1 toward site 2 (mean value, 80.15 to 25.79 mg.l-1). A clear gradual increase in mineral content (TDS) observed from site one of the channel towards the mouthpart. Soluble reactive phosphate has a concentration maximum mean value reached 48.4 µg.l-1 which is recorded in site 2. A high positive relationship (P<0.01, r =0.449) obtained between phosphate concentration and phytoplankton density. The results of chlorophyll-a concentration were (mean values, 2.26, 3.88 and 2.42 µg.l-1 respectively), showed the positive relationship (P<0.05, r =0.012) with phytoplankton density. The PCA produced three significant main components which represented by more than 64.5% of the total variance, namely, nutrients related to algal productivity; disposal wastewater and storm water runoff, in which explained by 31.29, 19.68 and 13.55% respectively of the total variance of water quality in polluted channel.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Mar 13 2011
Journal Name
Baghdad Science Journal
Lead bioremoval by Bacillus spp. Isolated from industrial wastewater
...Show More Authors

Four samples were collected from the wastewater of State Battery Manufacturing Company (SBMC); Babylon 2 factory in AL-Waziriya district, as triplicates. Physical and chemical measurements were carried out such as temperature, pH, Lead concentrations and their ranges were: (19.5-34.5) °C, (6.1-6.4) and (4.5-6.5) mg/L, respectively. Six dominant Bacillus spp. isolates were isolated from these samples; namely, Bacillus subtilis N1, Bacillus subtilis N2, Bacillus subtilis N3, Bacillus cereus N4, Bacillus cereus N5 , Bacillus cereus N6. These isolates were capable of removing Lead from aqueous solutions in a capacity reached 27.6 ± 1.4, 10.1 ± 1.7, 74.5 ± 0.7, 8.93 ± 2.8, 8.1 ± 3.5, 1.6± 0.7 mg/L, respectively. Whereas cell walls,

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Aug 17 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Preliminary study on the phytoplankton of the marshes Al-Sallal , Al- Hwizah and Al­ Chebiaysh - South Iraq
...Show More Authors

Phytoplankton  flora in southern marshes of govemorate Al- Basrah ( Al-SallaJ   marsh   )                                  Meissan   (Al-   Hwizah   marsh)   and   Di-qar   (Al­ Chebiaysh  marsh ) were studied from August 12005 to November /2005,

Four Stations were Chosen in each marsh. Identified  species and total

cell count were recorded . As aquality study, (35) species of algae were identified belonged to (23) genus in Al-Sallal  marsh  , (46) speci

... Show More
View Publication Preview PDF
Publication Date
Sun Apr 30 2017
Journal Name
Journal Of Engineering
Biotreatment of Slaughterhouse Wastewater Accompanied with Electrcity Generation and Nutrients Recovery in Microbial Fuel Cell
...Show More Authors

In recent years and decades, there is a great need for developing new alternative energy sources or renewable sustainable energy. On the other hand, new technology approaches are growing . towards benefits from the valuable nutrients in wastewater which are unrecoverable by traditional wastewater treatment processes.  In the current study, a novel integrated system of microbial fuel cell and anoxic bioreactor (MFC-ANB) was designed and constructed to investigate its potential for slaughterhouses wastewater treatment, nitrogen recovery, and power generation. The system consisted of a double-chamber tubular type MFC with biocathode inoculated with freshly collected activated sludge. The MFC-ANB system was continuously fed with real-fi

... Show More
View Publication Preview PDF
Publication Date
Fri Dec 30 2022
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Mathematical Modeling and Kinetics of Removing Metal Ions from Industrial Wastewater
...Show More Authors

The study's objective is to produce Nano Graphene Oxide (GO) before using it for batch adsorption to remove heavy metals (Cadmium Cd+2, Nickel Ni+2, and Vanadium V+5) ions from industrial wastewater. The temperature effect (20-50) °C and initial concentration effect (100-800) mg L-1 on the adsorption process were studied. A simulation aqueous solution of the ions was used to identify the adsorption isotherms, and after the experimental data was collected, the sorption process was studied kinetically and thermodynamically. The Langmuir, Freundlich, and Temkin isotherm models were used to fit the data. The results showed that Cd, Ni, and V ions on the GO adsorbing surface matched the Langmuir mo

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Fri Jan 01 2021
Journal Name
Environmental Engineering And Management Journal
TREATMENT OF DAIRY WASTEWATER BY ELECTROCOAGULATION AND ULTRASONIC-ASSISTED ELECTROCOAGULATION METHODS
...Show More Authors

View Publication
Crossref (4)
Crossref
Publication Date
Wed Feb 01 2017
Journal Name
International Journal Of Science And Research (ijsr)
Performance Evaluation of the Organic Matter Removal Efficiency in Wastewater Treatment Plants; Case study Al- Diwaniyah WWTP in Iraq
...Show More Authors

This study aims to assess the removal efficiency andestablish the BOD5 and COD statisticalcorrelation of the sewage flowing in Al-Diwaniyah wastewater treatment plant in Iraq during the study period (2005-2016). The strength of the influent wastewater entering the plant varied from medium to high in strength. High concentrations of BOD5 and COD in the effluent were obtained due to the poor performance of the plant. This was observed from the BOD5 /COD ratios that did not confirm with the typical ratios for the treated sewage. To improve the performance of this plant, regression equations for BOD5 and COD removal percentages were suggested which can be used to facilitate evaluation of liquid waste and optimal control process. The equations

... Show More
Publication Date
Wed Aug 28 2019
Journal Name
Journal Of Engineering
Treatment of Simulated Carwash Wastewater by Electrocoagulation with Sonic Energy
...Show More Authors

Oily carwash wastewater is a high organic and chemical wastewater. This paper targeted to investigate a treatment to decrease the water consumption and contaminants in car-washing stations. Electrocoagulation combined with ultrasonic energy (Sono-Electrocoagulation) was suggested so that the carwash wastewater is treated to be reused. The effect of both the voltage and time of treatment on the removal of COD, turbidity, conductivity, and total dissolved solids (TDS) were studied at constant initial pH 7 and electrode distance 2 cm. The results showed the best results of removal COD, turbidity, TDS, and reduce electrical conductivity is when the voltage was 30 V and a treatment time of 90 minutes.

  <

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Wed Dec 01 2021
Journal Name
Baghdad Science Journal
Drinking water quality evaluation of hand pumping wells using water quality index and standard algal toxicity testing in Mansoura and Talkha cities, Egypt
...Show More Authors

Six house-hold Abyssinian pumps distributed in different villages of Mansoura (Mans-I, Mans-II and Mans-III) and Talkha (Talk-I, Talk-II and Talk-III) cities, Egypt, have been selected for regular seasonal water quality assessment during 2017. Water samples have been collected within the mid-periods of four seasons Standard assessment tools were employed for the integrated water quality assessment including Water Quality Index (WQI) and ISO standard algal toxicity test. WQI displayed remarkable local and seasonal variations with excellent (≥ 90) and good (70 - 89) only recorded for water samples collected from Mans-I pump located in sparsely populated area and far 50 meters only from the eastern (Damietta) branch of Nile River. WQI of

... Show More
View Publication Preview PDF
Scopus (3)
Scopus Clarivate Crossref
Publication Date
Fri Oct 30 2020
Journal Name
Journal Of Economics And Administrative Sciences
The Effect of Brainstorming on audit Quality and its Reflection on Detecting the Risk of Fraud
...Show More Authors

Brainstorming is one of the fundamental and necessary concepts for practising the auditing profession, as auditing standards encouraged the implementation of brainstorming sessions to reach reasonable assurance about the validity of the evidence and information obtained by the auditor to detect fraud, as the implementation of brainstorming sessions and the practice of professional suspicion during the audit process lead To increase the quality of auditing and thus raise the financial community's confidence in the auditing profession again after it was exposed to several crises that led to the financial community losing confidence in the auditing profession.

The research aims to explain the effect of brain

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Oct 01 2019
Journal Name
Journal Of Engineering
Carwash Wastewater Treatment by Electrocoagulation Using Aluminum Foil Electrodes
...Show More Authors

Large quantities of contaminated carwash wastewater are produced per day from carwash places. Extensively it contains large quantities of chemicals from detergents, oil, grease, heavy metals, suspended solids, types of hydrocarbons, and biological contents. A novel electrocoagulation treatment by foil electrodes was conducted to remove COD, turbidity, Total Dissolved Solids (TDS) from contaminated carwash wastewater and decrease its Electrical Conductivity (EC). A thin layer of aluminum foil is used as an electrode in this treatment process. The effects of different voltage and treatment times were studied. The best result was found at a voltage of 30 volts and treatment time 90 minute where the removal efficiency of COD

... Show More
View Publication Preview PDF
Crossref (8)
Crossref