Preferred Language
Articles
/
bijps-974
Comparing the Efficacy of Paracetamol, Diclofenac, and Ketorolac on Post-Appendectomy Outcomes in Children and Adolescents
...Show More Authors

Abstract

urgent surgical intervention and appendectomy until now represent standard treatment for uncomplicated cases of appendicitis. Nausea, vomiting and pain after surgery are the most frequent issues facing patients and affecting patient quality of life and responsible for many cases of readmission after surgery. Ketorolac and diclofenac represent the most commonly prescribed non-steroidal anti-inflammatory used in postoperative setting and they cause many side effects as gastrointestinal, kidney and cardiac adverse effect in addition to increased risk of bleeding. Paracetamol is currently among the most frequently prescribed medication worldwide and it can be used safely for all age groups. This study aimed to compare the analgesic efficacy and safety of paracetamol, diclofenac, and ketorolac when used after appendectomy and to assess their efficacy regarding nausea and vomiting in children and adolescents. A randomized, single-blinded, comparative, observational prospective clinical study was carried out on patients diagnosed with acute appendicitis and assigned for emergent appendectomy between October 2018 to May 2019 in Al- Zahraa Teaching Hospital in Al-Najaf province, Iraq.120 patients were randomly distributed into three groups who received diclofenac sodium suppositories (2mg/kg), IV Paracetamol )15mg/ kg every 6 hr.(, and IV  Ketorolac )0.5mg/ kg( immediately after surgery. All patients were observed for pain, nausea and vomiting and bleeding. Patients received ketorolac had a high percentage of the decrease in pain score between 30 and 60 min. after surgery, while paracetamol was the next and diclofenac sodium was the last. Regarding nausea and vomiting after surgery, ketorolac had higher percentage of the decrease in nausea, vomiting score during first day after surgery followed by diclofenac and paracetamol respectively. The present study also showed that there is no significant difference between groups regarding bleeding after surgery. It is concluded that ketorolac has higher analgesic efficacy compared with paracetamol and diclofenac with no risk of nausea and vomiting and bleeding when used after appendectomy.

Keywords: Postoperative pain, Ketorolac, Diclofenac, Paracetamol, Appendectomy.

 

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Mar 01 2023
Journal Name
Journal Of Engineering
Producing Load Bearing Block Using LECA as Partial Replacement of Coarse Aggregate
...Show More Authors

The ability to produce load-bearing masonry units adopting ACI 211.1 mix design using (1:3.2:2.5) as (cement: fine aggregate: coarse aggregate) with slump range (25-50mm) which can conform (dimension, absorption, and compressive strength) within IQS 1077/1987 requirements type A was our main goal of the study. The ability to use low cement content (300 kg/m3) to handle our market price products since the most consumption in wall construction for low-cost buildings was encouraging. The use of (10 and 20%) of LECA as partial volume replacement of coarse aggregate to reduce the huge weight of masonry blocks can also be recommended. The types of production of the load-bearing masonry units were A and B for (

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Mon Feb 03 2025
Journal Name
Journal Of Baghdad College Of Dentistry
A Micro Computed Tomography Assessment of New Carrier-Based Root Canal Fillings
...Show More Authors

Background: The main aim of the present study is to qualify and quantify voids formation of root canals obturated with GuttaCore (GC) and experimental Hydroxyapatite polyethylene (HA/PE) as new carrier-based root canal fillings by using micro computed tomography scan. Materials and methods: In the present study, eight straight single-rooted human permanent premolar teeth are selected and disinfected, then stored in distilled water. The teeth decoronated leaving a root length of 12mm each. The root canals instrumented by using crown down technique and the apical diameter of the root canal prepared to a size # 30/0.04 for achieving standardized measurements. A 5mL of 17% EDTA used to remove the smear layer followed by 5mL of 2.5% NaOCl and r

... Show More
View Publication Preview PDF
Publication Date
Fri Nov 05 2021
Journal Name
Journal Of Architectural Environment & Structural Engineering Research
Strength & Conduct of Reinforced Concrete Corner Joint under Negative Moment Effect
...Show More Authors

The aim of our study is to reveal the effect of steel reinforcement details,tensile steel reinforcement ratio, compressed reinforcing steel ratio,reinforcing steel size, corner joint shape on the strength of reinforcedconcrete Fc' and delve into it for the most accurate details and concreteconnections about the behavior and resistance of the corner joint ofreinforced concrete, Depending on the available studies and sources inaddition to our study, we concluded that each of these effects had a clearrole in the behavior and resistance of the corner joint of reinforced concreteunder the influence of the negative moment and yield stress. A studyof the types of faults that can be reinforced angle joints obtains detailsand conditions of c

... Show More
View Publication
Crossref (14)
Crossref
Publication Date
Fri Jan 01 2021
Journal Name
Materials Today:proceeding
Modification of CR39 surfaces by 193 nm ArF laser for biomaterial sensing
...Show More Authors

Scopus (2)
Scopus
Publication Date
Thu Sep 01 2022
Journal Name
International Journal Of Engineering Transactions C: Aspects
Axial Behavior of Concrete Filled-steel Tube Columns Reinforced with Steel Fibers
...Show More Authors

Concrete filled steel tube (CFST) columns are being popular in civil engineering due to their superior structural characteristics. This paper investigates enhancement in axial behavior of CFST columns by adding steel fibers to plain concrete that infill steel tubes. Four specimens were prepared: two square columns (100*100 mm) and two circular columns (100 mm in diameter). All columns were 60 cm in length. Plain concrete mix and concrete reinforced with steel fibers were used to infill steel tube columns. Ultimate axial load capacity, ductility and failure mode are discussed in this study. The results showed that the ultimate axial load capacity of CFST columns reinforced with steel fibers increased by 28% and 20 % for circular and square c

... Show More
Scopus (6)
Crossref (9)
Scopus Clarivate Crossref
Publication Date
Fri Nov 01 2019
Journal Name
Practice Periodical On Structural Design And Construction
Reducing Damages to Underground Infrastructure: Performance Evaluation of One-Call Notification Program
...Show More Authors

View Publication
Scopus (11)
Crossref (9)
Scopus Clarivate Crossref
Publication Date
Wed Aug 30 2023
Journal Name
Iraqi Journal Of Science
3D MHD Radiation Flow of Unsteady Casson Fluid with Viscous Dissipation Effect
...Show More Authors

A numerical evaluation of the crucial physical properties of a 3D unsteady MHD flow along a stretching sheet for a Casson fluid in the presence of radiation and viscous dissipation has been carried out. Meanwhile, by applying similarity transformations, the nonlinear partial differential equations (PDEs) are transformed into a system of ordinary differential equations (ODEs). Furthermore, in the numerical solution of nonlinear ODEs, the shooting method along with Adams Moulton method of order four has been used. The obtained numerical results are computed with the help of FORTRAN. The tables and graphs describe the numerical results for different physical parameters which affect the velocity and temperature profiles.

View Publication Preview PDF
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Fri Jul 01 2016
Journal Name
Journal Of Engineering
Determination of Mono-crystalline Silicon Photovoltaic Module Parameters Using Three Different Methods
...Show More Authors

For modeling a photovoltaic module, it is necessary to calculate the basic parameters which control the current-voltage characteristic curves, that is not provided by the manufacturer. Generally, for mono crystalline silicon module, the shunt resistance is generally high, and it is neglected in this model. In this study, three methods are presented for four parameters model. Explicit simplified method based on an analytical solution, slope method based on manufacturer data, and iterative method based on a numerical resolution. The results obtained for these methods were compared with experimental measured data. The iterative method was more accurate than the other two methods but more complexity. The average deviation of

... Show More
View Publication Preview PDF
Publication Date
Thu Feb 07 2019
Journal Name
Journal Of The College Of Education For Women
Iraqi Third Year College Students' Recognition of English Idioms: A Comparative Study
...Show More Authors

An idiom is a group of words whose meaning put together is different from the meaning of
individual words. English is a rich language when it comes to idioms, they represent variety. For
foreign learners, idioms are problematic because even if they know the meaning of individual
words that compose an idiom the meaning of it might be something completely different.
The present study investigates Iraqi third year college students’ recognition of idioms. To
achieve this, the researchers have conducted a test which comprises three questions. Certain
conclusions are reached here along with some suggestions and recommendations.

View Publication Preview PDF
Publication Date
Wed Mar 30 2022
Journal Name
Iraqi Journal Of Science
Spectroscopic Study of Plasma Parameters Produced by Pin-Plate DC Discharge Technique
...Show More Authors

     In this work, plasma parameters such as electron density (ne), electron temperature (Te), Debye length (λD), plasma frequency (fPlasma), and Debye number (ND) for Cu plasma produced by Pin-Plate DC discharge were studied. Spectroscopic technique was used to analyze and determine spectral emission lines. The value of the electron density for Cu was in the range (1.5–3.5)×1018cm-3 and for the electron temperature was in the range ( 1.31 – 1.61)eV. Finally, plasma parameters of Cu were caculated through plasma produced by Pin-Plate DC discharge using different voltages (600-900) V.

View Publication Preview PDF
Scopus (2)
Crossref (1)
Scopus Crossref