Preferred Language
Articles
/
bijps-939
Enhancement of Aqueous Solubility and Dissolution Rate of Etoricoxib by Solid Dispersion Technique
...Show More Authors

Etoricoxib (EXB) is a highly selective cox-2 inhibitor which belongs to the non-steroidal anti-inflammatory drug (NSAID). EXB is a class II drug according to the biopharmaceutical classification system (BCS), which possess a very low aqueous solubility in water.  In the present study, many trials were made to improve the aqueous solubility and dissolution rate of EXB by solid dispersion technique.

Eighteenth EXB formulas were formulated as a solid dispersion using a variety of hydrophilic polymers (as carriers)   including poloxamer 407 (PXM 407), poloxamer 188 (PXM 188) and polyethylene glycol 4000 (PEG 4000) at different drug: polymer ratios (1:1, 1:3 and 1:5). These formulas were prepared by two methods; solvent evaporation and fusion method. The prepared formulas were evaluated for practical yield percent (PY %), drug content, saturated solubility and release rate, Fourier transforms infrared spectroscopy (FTIR), differential scanning calorimetry (DSC) and powder x-ray diffraction (PXRD).

It was found that the solubility was affected by the polymer type and the method of preparation. The polymers (as carriers) used to prepare EXB- solid dispersion showed improvement in the solubility in the following descending order; PXM 407>PXM 188> PEG 4000. The optimum formula (SD15) composed of the drug: PXM 407 at a ratio of 1:5 was prepared by solvent evaporation showed 7.76 folds (676.40%) solubility improvement as compared to pure EXB. The optimum formula showed a release rate of 99.8% through the first 15 min. The advance characterization of the selected formula indicated the possible transformation of the drug to the amorphous state.

Keywords: EXB, Solid dispersion, PXM 407, PXM 188, PEG 4000.

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Oct 25 2022
Journal Name
Vi. International Scientific Congress Of Pure, Applied And Technological Sciences
Study the effect of adding alcoholic and aqueous extract of turmeric to processed chees as natural antioxidant and in improving its physicochemical properties
...Show More Authors

View Publication
Publication Date
Sun Jun 01 2014
Journal Name
Baghdad Science Journal
Study affects Pulse Parameters versus cavity length for both Dispersion Regimes in FM mode locked.: Bushra.R.Mhdi|Gaillan H.Abdullah|Mohand M.Azzawi|Nahla.A.Hessin|Basher.R.Mhdi
...Show More Authors

To demonstrate the effect of changing cavity length for FM mode locked on pulse parameters and make comparison for both dispersion regime , a plot for each pulse parameter as Lr function are presented for normal and anomalous dispersion regimes . The analysis is based on the theoretical study and the results of numerical simulation using MATLAB. The effect of both normal and anomalous dispersion regimes on output pulses is investigate Fiber length effects on pulse parameters are investigated by driving the modulator into different values. A numerical solution for model equations using fourth-fifth order, Runge-Kutta method is performed through MATLAB 7.0 program. Fiber length effect on pulse parameters is investigated by driving th

... Show More
View Publication
Crossref
Publication Date
Fri Jul 19 2024
Journal Name
Applied Science And Engineering Progress
Multicomponent Equilibrium Isotherms and Kinetics Study of Heavy Metals Removal from Aqueous Solutions Using Electrocoagulation Combined with Mordenite Zeolite and Ultrasonication
...Show More Authors

Combining different treatment strategies successively or simultaneously has become recommended to achieve high purification standards for the treated discharged water. The current work focused on combining electrocoagulation, ion-exchange, and ultrasonication treatment approaches for the simultaneous removal of copper, nickel, and zinc ions from water. The removal of the three studied ions was significantly enhanced by increasing the power density (4–10 mA/cm2) and NaCl salt concentration (0.5–1.5 g/L) at a natural solution pH. The simultaneous removal of these metal ions at 4 mA/cm2 and 1 g NaCl/L was highly improved by introducing 1 g/L of mordenite zeolite as an ion-exchanger. A remarkable removal of heavy metals was reported

... Show More
View Publication
Scopus Crossref
Publication Date
Fri Jul 19 2024
Journal Name
Applied Science And Engineering Progress
Multicomponent Equilibrium Isotherms and Kinetics Study of Heavy Metals Removal from Aqueous Solutions Using Electrocoagulation Combined with Mordenite Zeolite and Ultrasonication
...Show More Authors

Combining different treatment strategies successively or simultaneously has become recommended to achieve high purification standards for the treated discharged water. The current work focused on combining electrocoagulation, ion-exchange, and ultrasonication treatment approaches for the simultaneous removal of copper, nickel, and zinc ions from water. The removal of the three studied ions was significantly enhanced by increasing the power density (4–10 mA/cm2) and NaCl salt concentration (0.5–1.5 g/L) at a natural solution pH. The simultaneous removal of these metal ions at 4 mA/cm2 and 1 g NaCl/L was highly improved by introducing 1 g/L of mordenite zeolite as an ion-exchanger. A remarkable removal of heavy metals was reported

... Show More
View Publication
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Wed Jan 01 2020
Journal Name
Annals Of Tropical Medicine And Public Health
Isolation and identification of fungi from fish feedstuff of cyprinus carpio and detection of aflatoxin b1 and ochratoxin a using ELISA technique
...Show More Authors

This study was conducted at the College of Education for Pure Sciences (Ibn Al-Haitham), University of Baghdad. The aim of this study was to isolate and diagnose fungi from fish feedstuff samples, and also detection of aflatoxin B1 and ochratoxin A in fish muscles and feedstuffs. Randomly, the samples were collected from some fish farms from Baghdad, Babil, Wasit, Anbar, and Salah al-Din provinces. This study included the collection of 35 feedstuff samples and 70 fish muscle samples, and each of the two fish samples fed on one sample of the feedstuff. The results showed the presence of several genera of different fungi including Aspergillus spp, Mucor spp., Penicillium spp., Yeast spp., Fusarium spp., Rhizopus spp., Scopiolariopsis spp., Ep

... Show More
View Publication
Crossref (1)
Crossref
Publication Date
Mon Jan 08 2024
Journal Name
Al-rafidain Journal Of Medical Sciences ( Issn 2789-3219 )
Recurrence Rate of Pleomorphic Adenoma in Minor Salivary Glands After Surgical Excision: A Retrospective Clinical Study
...Show More Authors

Background: Pleomorphic adenoma of the minor salivary gland is a rare benign tumor. It commonly occurs in the hard and soft palates. Treatment by surgical excision achieved success in improving the patient’s health. Objective: To evaluate the recurrence rate after surgical treatment of pleomorphic adenoma in minor salivary glands. Methods: This retrospective study included patients who attended the Maxillofacial Surgery Unit in Ghazi Al-Hariri Hospital, Baghdad, from 2019 to 2021, complaining of soft tissue lumps involving the soft and hard palate, buccal mucosa, and upper lip. After the provisional diagnosis of these lesions, a total surgical excision of the tumor with a safe margin of 1 mm was performed, and the biopsy was sent

... Show More
View Publication Preview PDF
Scopus (1)
Scopus Crossref
Publication Date
Mon Jan 08 2024
Journal Name
Al-rafidain Journal Of Medical Sciences ( Issn 2789-3219 )
Recurrence Rate of Pleomorphic Adenoma in Minor Salivary Glands After Surgical Excision: A Retrospective Clinical Study
...Show More Authors

Background: Pleomorphic adenoma of the minor salivary gland is a rare benign tumor. It commonly occurs in the hard and soft palates. Treatment by surgical excision achieved success in improving the patient’s health. Objective: To evaluate the recurrence rate after surgical treatment of pleomorphic adenoma in minor salivary glands. Methods: This retrospective study included patients who attended the Maxillofacial Surgery Unit in Ghazi Al-Hariri Hospital, Baghdad, from 2019 to 2021, complaining of soft tissue lumps involving the soft and hard palate, buccal mucosa, and upper lip. After the provisional diagnosis of these lesions, a total surgical excision of the tumor with a safe margin of 1 mm was performed, and the biopsy was sent for hist

... Show More
View Publication Preview PDF
Scopus (1)
Scopus Crossref
Publication Date
Wed Jun 10 2009
Journal Name
Iraqi Journal Of Laser
Simulation of passively Q-switched rate equation using saturable crystal Dy +2: CaF2 with ruby laser
...Show More Authors

The simulation of passively Q-switching is four non – linear first order differential equations. The optimization of passively Q-switching simulation was carried out using the constrained Rosenbrock technique. The maximization option in this technique was utilized to the fourth equation as an objective function; the parameters, γa, γc and β as were dealt with as decision variables. A FORTRAN program was written to determine the optimum values of the decision variables through the simulation of the four coupled equations, for ruby laser Q–switched by Dy +2: CaF2.For different Dy +2:CaF2 molecules number, the values of decision variables was predicted using our written program. The relaxation time of Dy +2: CaF2, used with ruby was

... Show More
View Publication Preview PDF
Publication Date
Wed Jan 15 2020
Journal Name
Iraqi Journal Of Laser
Optimizing the Secure Key Rate of a Single Sequential Quantum Repeater with Two Different Quantum Memories
...Show More Authors

Quantum channels enable the achievement of communication tasks inaccessible to their
classical counterparts. The most famous example is the distribution of secret keys. Unfortunately, the rate
of generation of the secret key by direct transmission is fundamentally limited by the distance. This limit
can be overcome by the implementation of a quantum repeater. In order to boost the performance of the
repeater, a quantum repeater based on cut-off with two different types of quantum memories is suggestd,
which reduces the effect of decoherence during the storage of a quantum state.

View Publication Preview PDF
Publication Date
Wed Apr 10 2019
Journal Name
Engineering, Technology & Applied Science Research
Content Based Image Clustering Technique Using Statistical Features and Genetic Algorithm
...Show More Authors

Text based-image clustering (TBIC) is an insufficient approach for clustering related web images. It is a challenging task to abstract the visual features of images with the support of textual information in a database. In content-based image clustering (CBIC), image data are clustered on the foundation of specific features like texture, colors, boundaries, shapes. In this paper, an effective CBIC) technique is presented, which uses texture and statistical features of the images. The statistical features or moments of colors (mean, skewness, standard deviation, kurtosis, and variance) are extracted from the images. These features are collected in a one dimension array, and then genetic algorithm (GA) is applied for image clustering.

... Show More
View Publication
Scopus (6)
Crossref (2)
Scopus Crossref