Preferred Language
Articles
/
bijps-784
Formulation and In- Vitro Evaluation of Spherical Crystal Agglomerates of Ebastine by Quasi Emulsion Solvent Diffusion Method
...Show More Authors

Ebastine (EBS) is a poorly water-soluble antihistaminic drug; it belongs to the class II group according to the biopharmaceutical classification system (BCS). The aim of the present work was to enhance the solubility, dissolution rate and micromeritic properties of the drug, by formulating it as spherical crystal agglomerates by Quasi Emulsion Solvent Diffusion (QESD) method.

Spherical crystal agglomerates (SCAs) were prepared in presence of three solvents dichloromethane (DCM), water and chloroform as a good solvent, poor solvent and bridging solvent respectively.  Agglomeration of EBS involved the use of some hydrophilic polymers like polyethylene glycol 4000 (PEG 4000), polyvinyl pyrrolidine K30 (PVP K30), D-?-tocopheryl polyethylene glycol 1000 succinate (TPGS) and ?. cyclodextrin. The pure drug (EBS) and its agglomerates with and without polymers were characterized for their drug content, percentage yield, solubility, in vitro drug release study and micromeritic property as well as by optical microscope, Scanning Electron Microscopy (SEM), FTIR spectroscopic studies, Differential Scanning Calorimetry (DSC) and X-ray Diffraction (XRD). The results of this work showed that there was a   marketed enhancement in the solubility with improvement in dissolution rate, physiochemical properties, decrease in crystallinity and alteration in the crystal habit of the drug especially in presence of polymers. The best results were obtained with formula prepared by the combination of PEG 4000 and B. cyclodextrin in the agglomeration process of (EBS).

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Mar 01 2010
Journal Name
Journal Of Al-nahrain University
DETERMINATION OF SERUM TRACE ELEMENTSMAGNESIUM, COPPER, ZINC, AND SELENIUM IN ASTHMATIC PATIENTS BY ATOMIC ABSORPTION SPECTROPHOTOMETRY
...Show More Authors

The aim of this study is to evaluate the levels of trace elements Magnesium (Mg), Zinc (Zn), Copper (Cu), and Selenium (Se) in blood sera of asthmatic patients by Atomic Absorption Spectrophotometry (AAS). The concentrations of Mg, Cu, and Zn have been determined by Flame Atomic Absorption spectrophotometry (FAAS), and Se with flameless Graphite Furnace Atomic Absorption Spectrophotometry (GFAAS). The study involves (55) asthmatic patients as study group and (28) subjects as control from both genders. Serum levels of Mg, Cu, and Se were significantly higher (p<0.001 for all) in patients when compared with healthy subjects, while Zn level was relatively significant (p<0.05). Our observations confirm the efficacy and applicability of (AAS) in

... Show More
Preview PDF
Publication Date
Tue Jan 13 2015
Journal Name
European Journal Of Scientific Research
Determination of Priority Pollutant Phenols in PetroleumRefinery Wastewater and Tigris River Water by SPE-HPLC-UV
...Show More Authors

A solid Phase Extraction (SPE) followed by HPLC-UV method is described for the simultaneous quantitative determination of nine priority pollutant phenols : Phenol, 2- and 4-Nitrophenol, 2,4-Dimethylphenol, 2-, 2,4-Di-, 2,4,6-Tri-, and Penta- chlorophenol, 4 Chloro-3-methylphenol. The phenols were separated using a C-18 column with UV detector at wave length of 280nm. The Flow of mobile phase was isocratic consisted of 50:50 Acetonitrile: phosphate buffer pH=7.1, column temperature 45 C°, Flow Rate 0.7 ml/min. Calibration curves were linear (R2 = 0.9961-0.9995). The RSDs (1.301-5.805)%, LOD(39.1- 412.4) µg/L, LOQ(118.5-1250.8) µg/L, the Robustness (1.55-4.89), Ruggedness (2.82-4.00), Repeatability (2.1-4.95), Recoveries%

... Show More
Publication Date
Tue Oct 27 2026
Journal Name
Modern Sport
relationship between explosive power and length accurately by the performance of weavy sending skill in volleyball
...Show More Authors

View Publication
Publication Date
Wed Oct 12 2011
Journal Name
Journal Of Liquid Chromatography &amp; Related Technologies
RAPID DETERMINATION OF SPHINGANINE AND SPHINGOSINE IN URINE BY HIGH PERFORMANCE LIQUID CHROMATOGRAPHY USING MONOLITHIC COLUMN
...Show More Authors

A rapid high performance liquid chromatography method for the determination of sphinganine (Sa) and sphingosine (So) in urine samples by employing a silica-based monolithic column is described. The samples were first extracted using ethyl acetate and derivatized using ortho-phthaldialdehyde in the presence of 2-mercaptoethanol. C20 sphinganine was used as internal standard. Under the optimized conditions, separation was achieved using a mixture of methanol:water (93:7, v/v), column temperature at 30°C, flow rate of 1 mL min−1, and an injection volume of 10 μL. Good linearity was obtained for Sa and So over the concentration range 20–500 ng mL−1(correlation coefficients ≥0.9978). The detection limits were 0.45 ng mL−1 for Sa and

... Show More
View Publication
Scopus (1)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Wed Jan 30 2013
Journal Name
Al-kindy College Medical Journal
Disc Battery-The escalating risk of ingestion by children in IraqAnd subsequent clinical events and complications.
...Show More Authors

Background: Disc battery ingestion is a common
serious problem in Iraq. It increase in the last years
because of the increase in number of electronic toys
that uses these batteries. These batteries contains
many types of irritant chemicals that increases the
risk of it's ingestion.
Methods:We reviewed the medical records of
children aged between 1year and 7 years
old admitted to Surgical Specialty Hospital/Baghdad
Medical City due to disc battery ingestion from
January 2007 through December 2010). The diagnosis
of disc battery ingestion was based upon history,
clinical symptoms, and results of imaging studies.
The clinical data reviewed included sex, age, clinical
manifestation and duration of sy

... Show More
View Publication Preview PDF
Publication Date
Fri Apr 21 2023
Journal Name
Technologies And Materials For Renewable Energy, Environment And Sustainability: Tmrees22fr
Modified x-ray analysis size strain plot method to determine the lattice stress and strain energy density of calcium titan oxide (CaTiO3) nanoparticles
...Show More Authors

In this research, the size strain plot method was used to estimate the particle size and lattice strain of CaTiO3 nanoparticles. The SSP method was developed to calculate new variables, namely stress, and strain energy, and the results were crystallite size (44.7181794 nm) lattice strain (0.001211), This method has been modified to calculate new variables such as stress and its value (184.3046308X10-3Mpa) and strain energy and its value (1.115833287X10-6 KJm-3).

View Publication
Scopus Crossref
Publication Date
Thu Jan 01 2009
Journal Name
Ibn Al- Haitham J. Fo R Pure & Appl. Sci
Multiple Mixing Ratios of Gamma Rays Erγ)nEr(n, From 168 168 Reaction  Using a2 – Ratio Method
...Show More Authors

The -mixing of  - transition in Er 168 populated in Er)n,n(Er 168168  reaction is calculated in the present work by using a2- ratio method. This method has used in previou studies [4, 5, 6, 7] in case that the second transition is pure or for that transition which can be considered as pure only, but in one work we applied this method for two cases, in the first one for pure transition and in the 2nd one for non pure transitions. We take into accunt the experimental a2- coefficient for p revious works and -values for one transition only [1]. The results obtained are, in general, in agood agreement within associated errors, with those reported previously [1], the discrepancies that occur are due to inaccuracies existing

... Show More
Publication Date
Tue Jan 12 2021
Journal Name
Pollution Research
DETERMINATION OF ANILINE IN WASTEWATER BY CLOUDPOINT EXTRACTION FOLLOWED BY HPLC USING 8-HYDROXYQUINOLINE AS A DERIVATIZATION AGENT
...Show More Authors

A procedure, depending on the derivatization and determination of aniline was depicted andvalidated in this study. 8-hydroxyquinoline (8-HQ) was used as the derivatizing agent for thedetermination of aniline. An optimization study was performed for the derivatization reaction, i.e.,the diazonium coupling reaction, the optimum parameters were as follows: 22 mM of hydrochloricacid, 54mM of sodium hydroxide, and 1.8mM of sodium nitrate. The optimization study of themethod of cloud point extraction (CPE) revealed that the extraction solvent was 0.5 ml of Triton X-100, the optimum temperature was 90 °C, and the incubation time was 25 min. The linearity,correlation coefficients, molar absorptivities, and limits of detection were improved using t

... Show More
Publication Date
Mon Mar 02 2020
Journal Name
Journal Of Applied Research In Higher Education
Proposal of a guide for talent evaluation and management based on a qualitative and three-staged approach
...Show More Authors
Purpose

The key objective of the study is to understand the best processes that are currently used in managing talent in Australian higher education (AHE) and design a quantitative measurement of talent management processes (TMPs) for the higher education (HE) sector.

Design/methodology/approach

The three qualitative multi-method studies that are commonly used in empirical studies, namely, brainstorming, focus group discussions and semi-structured individual interviews were considered. Twenty-three individuals from six Australian universities parti

... Show More
View Publication
Scopus (9)
Crossref (5)
Scopus Clarivate Crossref
Publication Date
Wed Jan 01 2025
Journal Name
Ieee Access
Design and Comprehensive Study of a New Soft Electromagnetic Actuator: Mathematical Modeling, Numerical Analysis, and Experimental Evaluation
...Show More Authors

Soft robotics offers a flexible alternative to rigid systems, enabling safe and adaptive interaction in biomedical, wearable, and unstructured environments. Among available actuation methods, soft electromagnetic actuators are notable for their fast response, low operating voltage, and ease of integration. However, some designs require pre-stretching mechanism, which produces an external force to maintain the separation between the coil and permanent magnets. Additionally, there is a mechanical complexity and difficulty in calibrating the spring parameters precisely. Furthermore, the pre-stretching mechanism increases the electromagnetic force required to counteract the opposing spring force, leading to a significant increase in power consu

... Show More
View Publication
Scopus (1)
Crossref (1)
Scopus Crossref