Preferred Language
Articles
/
bijps-761
Spectrophotometric Determination of Chlordiazepoxide in Pharmaceutical Formulations via Oxidative Coupling Reaction with Phenothiazine
...Show More Authors

Abstract

A sensitive, precise and reliable indirect spectrophotometric method for the determination of chlordiazepoxide (CDE) in pure and pharmaceutical dosage forms is described. The method is based on oxidative coupling reaction between amino group resulting from acidic decomposition of CDE with phenothiazine in the presence of sodium periodate to produce an intense green soluble dye that is stable and shows a maximum absorption at 602 nm. The calibration plot indicates that Beer’s law is obeyed over the concentration range of 0.1?50 µg/mL, with a molar absorptivity of 1×104 L/mol cm and correlation coefficient of 0.9994.All the conditions that affecting on the stability and sensitivity of the formed product were studied and optimized and the suggested method was effectively applied for the determination of CDE in commercial dosage forms.

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Dec 16 2008
Journal Name
Iraqi Journal Of Laser
Primary Diagnosis of Abnormal Urine via Auto Fluorescence Process
...Show More Authors

The main objective of this study is to determine the suitable excitation wavelengths for
urine components reaching to select the suitable lasers to execute the auto fluorescence due to their
high intensities. The auto fluorescence was measured at 305, 325 and 350 nm excitation wavelengths
for eleven urine samples which were also analyzed by conventional methods (chemical and
microscopic examination). Data manipulation using Matlab package programming language showed
that urine sample with normal chemical and biological components have emission peaks which are
different from the infected urine samples. Despite the complexity of the composition of urine,
fluorescence maxima can be observed. Most likely, the peaks obser

... Show More
View Publication Preview PDF
Publication Date
Sat Feb 09 2019
Journal Name
Iraqi Journal Of Laser
Primary Diagnosis of Abnormal Urine via Auto Fluorescence Process
...Show More Authors

The main objective of this study is to determine the suitable excitation wavelengths for
urine components reaching to select the suitable lasers to execute the auto fluorescence due to their
high intensities. The auto fluorescence was measured at 305, 325 and 350 nm excitation wavelengths
for eleven urine samples which were also analyzed by conventional methods (chemical and
microscopic examination). Data manipulation using Matlab package programming language showed
that urine sample with normal chemical and biological components have emission peaks which are
different from the infected urine samples. Despite the complexity of the composition of urine,
fluorescence maxima can be observed. Most likely, the peaks obser

... Show More
View Publication Preview PDF
Publication Date
Wed Mar 01 2023
Journal Name
Al-khwarizmi Engineering Journal
Succinic acid Production Strategy: Raw material, Organisms and Recent Applications in pharmaceutical and Food: Critical Review
...Show More Authors

Succinic acid is an essential base ingredient for manufacturing various industrial chemicals. Succinic acid has been acknowledged as one of the most significant bio based building block chemicals. Rapid demand for succinic acid has been noticed in the last 10 years. The production methods and mechanisms developed. Hence, these techniques and operations need to be revised. Recently, an omnibus rule for developing succinic acid is to find renewable carbohydrate Feedstocks. The sustainability of the resource is crucial to disintegrate the massive use of petroleum based-production. Accordingly, systematically reviewing the latest findings of bacterial production and related fermentation methods is critical. Therefore, this paper aims to stud

... Show More
View Publication Preview PDF
Publication Date
Sun Dec 04 2016
Journal Name
Baghdad Science Journal
Mefenamic Acid Selective Membranes Sensor and Its Application to pharmaceutical Analysis
...Show More Authors

PVC membrane sensor for the selective determination of Mefenamic acid (MFA) was constructed. The sensor is based on ion association of MFA with Dodecaphospho molybdic acid (PMA) and Dodeca–Tungstophosphoric acid(PTA) as ion pairs. Nitro benzene (NB) and di-butyl phthalate (DBPH) were used as plasticizing agents in PVC matrix membranes. The specification of sensor based on PMA showed a linear response of a concentration range 1.0 × 10–2 –1.0 × 10–5 M, Nernstian slopes of 17.1-18.86 mV/ decade, detection limit of 7 × 10-5 -9.5 × 10 -7M, pH range 3 – 8 , with correlation coefficients lying between 0.9992 and 0.9976, respectively. By using the ionphore based on PTA gives a concentration range of 1.0 × 10–4 –1.0 × 10–5 M,

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Mar 30 2019
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Study on Kinetic and Optimization of Continuous Advanced Oxidative Decolorization of Brilliant Reactive Red Dye
...Show More Authors

The azo dye brilliant reactive red K-2BP (λmax = 534 nm) is widely used for coloring textiles because of its low-cost and tolerance fastness properties. Wastewaters treatment that contains the dye by conventional ways is usually inadequate due to its resistance to biological and chemical degradation. During this study, the continuous reactor of an advanced oxidation method supported the use of H2O2/sunlight, H2O2/UV, H2O2/TiO2/sunlight, and H2O2/TiO2/UV for decolorization of brilliant reactive red dye from the effluent. The existence of an optimum pH, H2O2 concentration, TiO2 concentration, and d

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Thu Jun 27 2024
Journal Name
Iraqi Journal Of Pharmaceutical Sciences( P-issn 1683 - 3597 E-issn 2521 - 3512)
Impact of Gliclazide Modified Release or Glimepiride as Add-on Therapy to Metformin on Glycemic and Oxidative Stress Parameters in Type 2 Diabetic Patients
...Show More Authors

Background: Type 2 diabetes mellitus is a condition characterized by an elevation of oxidative stress, which has been implicated in diabetic progression and its vascular complications. Aim: Assessing the impact of gliclazide modified release (MR) versus glimepiride on oxidative stress markers, glycemic indices, lipid profile, and estimated glomerular filtration rate in uncontrolled type 2 diabetic patients on metformin monotherapy. Methods: This was an observational comparative study conducted in Thi-Qar specialized diabetic, endocrine, and metabolism center. Sixty-six patients were randomized into two groups based on the addition of the sulfonylureas (SUs). Group 1 (33 patients) was on gliclazide MR, whereas Group 2 (33 patients)

... Show More
Preview PDF
Scopus (1)
Crossref (2)
Scopus Crossref
Publication Date
Sun Mar 30 2025
Journal Name
Studia Universitatis Babeș-bolyai Chemia
GREEN SPECTROPHOTOMETRIC METHOD FOR CONCURRENT ESTIMATION OF PIROXICAM AND MEFENAMIC ACID MIXTURE
...Show More Authors

The purpose of this work is to concurrently estimate the UVvisible spectra of binary combinations of piroxicam and mefenamic acid using the chemometric approach. To create the model, spectral data from 73 samples (with wavelengths between 200 and 400 nm) were employed. A two-layer artificial neural network model was created, with two neurons in the output layer and fourteen neurons in the hidden layer. The model was trained to simulate the concentrations and spectra of piroxicam and mefenamic acid. For piroxicam and mefenamic acid, respectively, the Levenberg-Marquardt algorithm with feed-forward back-propagation learning produced root mean square errors of prediction of 0.1679 μg/mL and 0.1154 μg/mL, with coefficients of determination of

... Show More
View Publication
Scopus Clarivate Crossref
Publication Date
Sun Mar 30 2025
Journal Name
Studia Universitatis Babeș-bolyai Chemia
GREEN SPECTROPHOTOMETRIC METHOD FOR CONCURRENT ESTIMATION OF PIROXICAM AND MEFENAMIC ACID MIXTURE
...Show More Authors

View Publication
Scopus Clarivate Crossref
Publication Date
Mon Feb 01 2016
Journal Name
Chemistry And Materials Research
Simple RP-HPLC Method for Estimation of Furosemide, Carbamazepine, Diazepam and Carvedilol in Bulk and Pharmaceutical Dosage Forms
...Show More Authors

A simple reverse-phase high performance liquid chromatographic method for the simultaneous analysis (separation and quantification) of furosemide (FURO), carbamazepine (CARB), diazepam (DIAZ) and carvedilol (CARV) has been developed and validated. The method was carried out on a NUCLEODUR® 100-5 C18ec column (250 x 4.6 mm, i. d.5μm), with a mobile phase comprising of acetonitrile: deionized water (50: 50 v/v, pH adjusted to 3.6 ±0.05 with acetic acid) at a flow rate 1.5 mL.min-1 and the quantification was achieved at 226 nm. The retention times of FURO, CARB, DIAZ and CARV were found to be 1.90 min, 2.79 min, 5.39 min and 9.56 min respectively. The method was validated in terms of linearity, accuracy, precision, limit of detection and li

... Show More
Publication Date
Tue Jan 09 2018
Journal Name
World Rural Observations
Solid cartridges in Determination of Benzidines in River and Wastewater by HPLC
...Show More Authors

A solid Phase Extraction (SPE) cartridges followed by HPLC-UV method is described for the simultaneous quantitative determination of benzidine (BZ) and its substituted 3, 3’-dichlorobenzidine (DCB) and 3, 3’-Dimethylbenzidine (DMB). The Benzidines were separated by liquid chromatography using a C-18 column with UV detector at wave length of 280nm. The mode of Flow was isocratic. The mobile phase was consisted of 75:25 methanol: water, column temperature 50C°, and Flow Rate 1.8ml/min. Calibration curves were linear (R2 = 0.9979-0.9995). LOD (26.36-33.67) µg/L, LOQ (109.98-186.11) µg/L, the Robustness (2.99-4.35), Ruggedness (2.93-3.65).Conditions of extraction by (SPE) cartridges were optimized, the resin used is Octadecyl silica (ODS

... Show More