Preferred Language
Articles
/
bijps-730
A Comparative Study of Blood Levels of Manganese, Some Macroelements and Heavy Metals in Obese and Non-Obese Polycystic Ovary Syndrome Patients
...Show More Authors

Polycystic ovary syndrome (PCOS) is a prevalent condition in women of reproductive age. It is characterized by androgen excess and chronic anovulation. Some trace elements, macroelements, and heavy metals have been linked to pathophysiological mechanisms of PCOS .

To study the alterations in the serum levels of the trace element manganese (Mn), some macroelements, magnesium(Mg) and calcium (Ca), and the heavy metals cadmium (Cd) and lead (Pb), in obese and non-obese PCOS patients; and the association of these alterations with some of the hormonal changes occurring in PCOS.

The study was carried out at Kamal Al-Samarrai Hospital (Center for Infertility treatment and in vitro Fertilization "IVF") Baghdad- Iraq. Eighty-two women were enrolled in the study. Fifty-four of them were diagnosed by a specialist gynecologist as PCOS patients; they were subdivided into two subgroups according to their body mass index (BMI); twenty-seven obese PCOS patients with BMI > 30 kg/m2, and another twenty seven non obese patients PCOS with BMI <30 kg/m2. Whereas, twenty-eight apparently healthy women with regular menstruation and of comparable age, were selected to serve as control groups; they were subdivided into, fourteen obese women with BMI > 30kg/m2, and fourteen non obese women with BMI <30 kg/m2.

Blood lead and cadmium levels were significantly higher in both of the obese and the non-obese PCOS groups, than in their corresponding control groups. While, serum magnesium, calcium and manganese levels were significantly lower in both of the obese and the non-obese PCOS groups, as compared to their corresponding control groups. The results revealed no significant difference in the levels of the measured elements, between the obese PCOS group and the non-obese PCOS group. The serum FSH levels was significantly lower in obese PCOS patients than in the obese and non-obese control groups. There was a positive correlation between blood lead and serum TSH levels in non-obese PCOS women; and between serum total testosterone and cadmium levels in obese PCOS women. Finally, there was negative correlation between serum magnesium and serum LH levels in non-obese PCOS women.

the study has demonstrated higher blood levels of lead and cadmium; and lower serum levels of magnesium, calcium and manganese in PCOS groups than control subject. There were no significant differences between obese PCOS women and non-obese PCOS women in the levels of the studied hormones, elements and heavy metals.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Feb 01 2019
Journal Name
Plant Archive
EFFECT OF ND:YAG (1064NM) ON STAPHYLOCOCCUS AUREUS ISOLATED FROM WOUNDS
...Show More Authors

Between October and December 2018, 27wounds and burn swab specimens were collected by laboratories at Al-Yarmook hospital, and cultured on Mannitol salt agar. the isolate was subjected to Nd: YAG laser in different power (400mJ, 500mJ, 800mJ and 900mJ). In general the laser showed effect on bacterial growth that reach to complete killing, the statistical analysis showed that there is weak correlation between laser at 400mJ with killed percentage. While in 500mJ its exhibit complete correlation with killing percentage, this correlation was decreased with increasing in power to 800mJ and 900Mj.

Publication Date
Sat Dec 30 2017
Journal Name
Al-khwarizmi Engineering Journal
Design & Implementation of High Switching & Low Phase Noise Frequency Synthesizer
...Show More Authors

This research  describes the design & implementation of frequency synthesizer using single loop Phase lock loop with the following specifications: Frequency range (1.5 – 2.75) GHz,Step size (1 MHz), Switching time 36.4 µs, & phase noise @10 kHz = -92dBc & spurious -100 dBc

  The development in I.C. technology provide the simplicity in the design of frequency synthesizer because it implements the phase frequency detector(PFD) , prescalar &  reference divider in single chip. Therefore our system consists of  a single chip contains (low phase noise PFD, charge pump, prescalar  & reference divider), voltage controlled oscillator , loop filter & reference oscillator. The single chip

... Show More
View Publication Preview PDF
Publication Date
Fri Mar 31 2017
Journal Name
Al-khwarizmi Engineering Journal
Mechanical Properties Investigation of Composite Material Under Different Parameters Variations
...Show More Authors

         The main objective of this research is to design and select a composite plate to be used in fabricating wing skins of light unman air vehicle (UAV). The mechanical properties, weight and cost are the basis criteria of this selection. The fiber volume fraction, fillers and type of fiber with three levels for each were considered to optimize the composite plate selection. Finite element method was used to investigate the stress distribution on the wing at cruise flight condition in addition to estimate the maximum stress. An experiments plan has been designed to get the data on the basis of Taguchi technique. The most effective parameters at the process to be find out by employing L9

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Jul 21 2023
Journal Name
Journal Of Engineering
Liquid-Liquid Extraction of Metal Ions Using Aqueous Biphasic Systems
...Show More Authors

An investigation was conducted for the study of extraction of metal ions using aqueous biphasic systems. The extraction of iron, zinc and copper from aqueous sulphate media at different kinds of extractants SCN− , Cl- and I- , different values of pH of the feed solution, phase ratio, concentration of metals, concentration of extractant, concentration of polymer, and concentration of salt was investigated. Atomic absorption spectrophotometer was used to measure the concentration of iron, zinc and copper in the aqueous phase throughout the experiments. The results of the extraction experiments showed the use of SCN− as extractant, pH=2.5, phase ratio=1.5, concentration of metals 1g/l, concentration of extractant 0.06 %, concentration o

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Wed Sep 15 2021
Journal Name
Al-academy
Space Interpretation of the Installation Art: رائد عبد الامير منصور
...Show More Authors

The research dealt with the study (interpretation of space in the art of installation), and it is located in four frameworks, the first is devoted to clarifying the research problem, its importance and the need for it, its goal, and its limits, and determining the most important terms contained therein.The research problem was determined from the question, does space embody those different and diverse materials that were formulated and installed by the artist into modern forms? Is the product of synthetic arts an appropriation of these spaces and domination of them?The problematic of interpreting space in its conceptual dimension in (synthetic) art in its multiplicity, diversity and difference, or objecting to the work of artistic system

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Mar 12 2020
Journal Name
Al-khwarizmi Engineering Journal
The Influence of ProcessVariables for MillingSculptured Surfaces on Surface Roughness
...Show More Authors

Increasing the variety of products that are being designed with sculptured surfaces, efficient machining of these surfaces has become more important in many manufacturing industries. The objective of the present work is the investigation of milling parameters for the sculptured surfacesthat effecting of surface roughness during machining of Al-alloy. The machining operation implemented on C-TEK CNC milling machine. The influence of the selected variables on the chosen characteristics have been accomplished using Taguchi design approach, also ANOVA had been utilized to evaluate the contributionsof each parameter on proc

... Show More
View Publication Preview PDF
Publication Date
Thu Sep 01 2022
Journal Name
Iraqi Journal Of Physics
Structural Properties of Prepared PANI/TiO2 Nanocomposite by Chemical Polymerization
...Show More Authors

A progression of Polyaniline (PANI) and Titanium dioxide (TiO2) nanoparticles (NPs) were prepared by an in-situ polymerization strategy within the sight of TiO2 NPs. The subsequent nanocomposites were analyzed using Fourier-transform infrared spectra (FTIR), X-ray diffraction (XRD), Scanning Electron Microscopy (SEM), and Energy Dispersive X-Ray Analysis (EDX) taken for the prepared samples. PANI/TiO2 nanocomposites were prepared by various compound materials (with H2SO4 0.3 M and without it, to compare the outcome of it) by the compound oxidation technique using ammonium persulfate (APS) as oxidant within the sight of ultrafine grade powder of TiO2 cooled in an ice bath.

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Tue Apr 30 2024
Journal Name
International Journal On Technical And Physical Problems Of Engineering
Deep Learning Techniques For Skull Stripping of Brain MR Images
...Show More Authors

Deep Learning Techniques For Skull Stripping of Brain MR Images

Scopus (2)
Scopus
Publication Date
Thu Mar 01 2007
Journal Name
Al-khwarizmi Engineering Journal
The Inverse Solution Of Dexterous Robot By Using Neural Networks
...Show More Authors

The inverse kinematics of redundant manipulators has infinite solutions by using conventional methods, so that, this work presents applicability of intelligent tool (artificial neural network ANN) for finding one desired solution from these solutions. The inverse analysis and trajectory planning of a three link redundant planar robot have been studied in this work using a proposed dual neural networks model (DNNM), which shows a predictable time decreasing in the training session. The effect of the number of the training sets on the DNNM output and the number of NN layers have been studied. Several trajectories have been implemented using point to point trajectory planning algorithm with DNNM and the result shows good accuracy of the end

... Show More
View Publication Preview PDF
Publication Date
Sun Mar 01 2009
Journal Name
Al-khwarizmi Engineering Journal
Multidimensional Systolic Arrays of LMS Algorithm Adaptive (FIR) Digital Filters
...Show More Authors

A multidimensional systolic arrays realization of LMS algorithm by a method of mapping regular algorithm onto processor array, are designed. They are based on appropriately selected 1-D systolic array filter that depends on the inner product sum systolic implementation. Various arrays may be derived that exhibit a regular arrangement of the cells (processors) and local interconnection pattern, which are important for VLSI implementation. It reduces latency time and increases the throughput rate in comparison to classical 1-D systolic arrays. The 3-D multilayered array consists of 2-D layers, which are connected with each other only by edges. Such arrays for LMS-based adaptive (FIR) filter may be opposed the fundamental requirements of fa

... Show More
View Publication Preview PDF