Copper (Cu) Zinc (Zn) and Magnesium (Mg) in serum, RBC, urine and dialyzate fluids were
studied in 39 patients, who have been undergoing chronic haemodialysis treatment. They were
divided in to polyuric , oliguric and anuric depending on their urinary output. Elevated serum and
RBC Mg was observed before dialysis, while decreased serum and RBC level was noticed except
serum Mg of polyuric patients. Before dialysis elevated serum and RBC Zn were observed. While
after dialysis these parameters were increased. Normal RBC Cu value before dialysis was observed.
While low serum Cu was noticed. After dialysis serum Cu showed raised value, while RBC level
decreased in oliguric and increased in polyuric patients. Zn / Cu ratio found to be high in those
patients. All these results were discussed in relation to urine content and also to the dialyzate fluid.
Key words: Trace elements, Haemodialysis, Renal failure
Background: ?-L-Fucose is a methyl pentose sugar, had the ability to kill bacteria, controlling infection and normalize immune function. The objective of this study is to determine the effect of sulcular injection of fucose on rabbits periodontium , throughout measuring the level of some proinflammatory cytokine ; interlukine 1beta ( IL-1beta) and tumor necrosis factor ( TNF-alpha) in sera of rabbits before fucose injection and at 3 days after fucose injection. Materials and Methods: The study was carried on using ( 20 ) male rabbits of the same species weighted (1-1.5 kg ) , the blood samples were collected from hearts of 20 rabbits before fucose injection and consider as( non injected group) , and after 3 days of fucose injection and con
... Show MoreBackground: Although bleaching is typically considered a safe procedure, various investigations have found minor negative effects and changes in mineral composition. The aim was to Evaluate and compare the efficacy of using Nanohydroxyapatite serum on surface microhardness of enamel surface before and after bleaching with chemically cured Boost bleaching. Material and methods: ten sound human permanent upper and lower premolar teeth were used and their roots were removed 2 mm apically to the cementoenamel junction, the crowns were sectioned mesiodistally into two halves buccal and lingual/palatal, the buccal surface was further subdivided into two halves. The samples were embeded in an acrylic resin, resulting in 30 specimens divide
... Show MoreThe preparation and characterization of innovative nanocomposites based on zinc oxide nanorods (ZNR) encapsulated by graphene (Gr) nanosheets and decorated with silver (Ag), and cupper (Cu) nanoparticles (NP) were studied. The prepared nanocomposites (ZNR@Gr/Cu-Ag) were examined by different techniques including Field Emission Scanning Electron Microscope (FESEM), Transmission electron microscopy (TEM), Atomic force microscopy (AFM), UV-Vis spectrophotometer and fluorescence spectroscopy. The results showed that the ZNR has been good cover by five layers of graphene and decorated with Ag and Cu NPs with particles size of about 10-15 nm. The ZNR@Gr/Cu-Ag nanocomposites exhibit high absorption behavior in ultraviolet (UV) region of sp
... Show MoreBackground: Osteoarthritis (OA) is a degenerative joint disease. It is one of the major causes of disability in developed and developing countries. Human leukocyte antigen (HLA) as part of immune system has a role in the disease process.Objectives: To investigate whether there is an association between HLA class II-DRB and OA.Methods: A case control study with 26 patients with osteoarthritis and 22 apparently healthy obese control persons matching in ethnicity were enrolled in this study during the period between October 2012 till March 2013. Direct interview was done with each patient and HLA typing was done by molecular method using Sequence Specific Primer (PCR-SSP) method using One Lambda Kit-USA. Results: The results showed that fem
... Show MoreThe present study aims at assessing the effects of chronic kidney disease (CKD) on thyroid hormone and leptin by evaluating the level of: leptin hormone along with thyroid hormone in CKD patients. The study has been conducted on 70 subjects, 50 patients with an age range between 20-50 years (25 males and 25 females) who were diagnosed to have CKD stage-5, and 20 normal controls whose ages ranged between 20-48 years (10 males and 10 females), who attended the Nephrology and Transplant Center in Medical City of Baghdad- Iraq from April 2018 to July 2018. The study showed a highly significant (P<0.01) increase in TSH level in CKD patients in comparison with controls. While T3 and T4 levels observed highly significant decrea
... Show MoreThis study was conducted to investigate thyroid function and Anti-Müllerian hormone (AMH) in (Chronic kidney disease) CKD patients by evaluating their levels in CKD patients, 50 patients were diagnosed to have CKD stage-5, their ages ranged between 20-50 years (25 males and 25 females) who attended the Nephrology and Transplant Center in Medical City of Baghdad- Iraq, they were recruited from April 2018 to July 2018 and were enrolled into the study. The control group consisted of 20 healthy individuals, their ages ranged between 20-48 years (10 males and 10 females). The study showed non-significant (p>0.05) increase in AMH level in CKD patients compared to the control group. On the other hand, TSH was recorded a highly significant (
... Show MoreKE Sharquie, AA Noaimi, AH Muhammad Ali, 2008 - Cited by 3
Copper, and its, alloys and composites (being the matrix), are broadly used in the electronic as well as bearing materials due to the excellent thermal and electrical conductivities it has.
In this study, powder metallurgy technique was used for the production of copper graphite composite with three volume perc ent of graphite. Processing parameters selected is (900) °C sintering temperature and (90) minutes holding time for samples that were heated in an inert atmosphere (argon gas). Wear test results showed a pronounced improvement in wear resistance as the percent of graphite increased which acts as solid lubricant (where wear rate was decreased by about 88% as compared with pure Cu). Microhardness and
... Show More