The Release of Diazepam from Different Conventional and Hollow Type Suppository Bases
...Show More Authors

The objective of this study was to investigate the release profile of different fat and water soluble bases using diazepam as a model drug , and then to develop  a satisfactory formula with a rapid release of diazepam from suppository bases .The study was conducted using theobroma oil ,glycerol-gelatin and glycerol-PEG1540 bases using conventional mold method for preparation .while the later base was utilized to incorporate diazepam ( buffered solution ) in a hollow type suppositories. The results indicated that all types of bases can be utilized to formulate diazepam as  rectal suppositories with acceptable disintegration time ( 12, 10, 6, and 6min.), respectively . While 100% of the  released drug had been shown different release profiles with different storage time ( 15, 30, and 45 days ) in a refrigerator at 5°C , best results were obtained , when glycerol- PEG1540 used as a base for both conventional and hollow type mold methods .However , a decrease in the release rate of the drug was seen with glycerol-gelatin and glycerol-PEG1540 and to a lesser extent for glycerol-PEG1540 prepared

by hollow type method .

Key words:  Diazepam  , Hollow type suppository

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Nov 19 2020
Journal Name
Indonesian Journal Of Chemistry
Determination of Eugenol in Personal-Care Products by Dispersive Liquid-Liquid Microextraction Followed by Spectrophotometry Using <i>p</i>-Amino-<i>N,N</i>-dimethylaniline as a Derivatizing Agent
...Show More Authors

Two simple methods for the determination of eugenol were developed. The first depends on the oxidative coupling of eugenol with p-amino-N,N-dimethylaniline (PADA) in the presence of K3[Fe(CN)6]. A linear regression calibration plot for eugenol was constructed at 600 nm, within a concentration range of 0.25-2.50 μg.mL–1 and a correlation coefficient (r) value of 0.9988. The limits of detection (LOD) and quantitation (LOQ) were 0.086 and 0.284 μg.mL–1, respectively. The second method is based on the dispersive liquid-liquid microextraction of the derivatized oxidative coupling product of eugenol with PADA. Under the optimized extraction procedure, the extracted colored product was determined spectrophotometrically at 618 nm. A l

... Show More
View Publication Preview PDF
Scopus (5)
Crossref (6)
Scopus Clarivate Crossref