Preferred Language
Articles
/
bijps-559
A Study on the Stability of Different Frusemide Liquid Dosage Formulas: Oral Solution, Syrup, Elixir, Suspension and Emulsion
...Show More Authors

The present study aim at preparing frusemide in liquid form suitable for oral use. This is achieved through preparing different liquid forms of frusemide. The frusemide liquid is prepared in the following forms: oral solution, syrup and elixir with intensity of 1, 0.4 and 0.8% weight /volume respectively and in combination with potassium carbonate, polysorbate 80, alcohol and phosphate buffer solution of pH8 to dissolve the frusemide in the above mentioned forms. The different forms of the prepared medicine have been stored in glass bottles that can provide protection against light and at 40, 50, 600C for four months. Besides the pH has been checked to decide the period of validity. The results show that the expiration date of frusemide have lasted for 1.8, 1.07 and 1.22 years respectively for the oral solution, the syrup and the elixir. The suspensions of frusemide are formulated in combination with the following: polyvinyl pyrolidine, xanthan gum, the combination of (xanthan gum and sodium carboxymethyl cellulose), the combination of (xanthan: methyl cellulose) and chitosan.  The formulas which give suitable release of the drug are chosen for assessment according to the following considerations: The rat of sedimentation and apparent zero order degradation constant at 250C. In conclusion, it is found the best formula is that which includes poly vinylpyrolidine, tween20, glycerol, sorbitol, cocoa syrup and parabens at pH7. the fluidity of this chosen formula is psendoplastic type and its validity has lasted for about three years. The emulsion of frusemide is also prepared extemporaneously by using the commercial frusemide tablets in combination with acacia and olive oil. This should be consumed within 45 days of the date of production.

Key word: frusemide, elixir, suspension, emulsion.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu May 31 2012
Journal Name
Al-khwarizmi Engineering Journal
The Stability Conditions of the Pump Structure Vibration
...Show More Authors

 The general approach of this research is to assume that the small nonlinearity can be separated from the linear part of the equation of motion. The effect of the dynamic fluid force on the pump structure system is considered vibrates at its natural frequency but the amplitude is determined by the initial conditions. If the motion of the system tends to increase the energy of the pump structure system, the vibration amplitude will increase and the pump structure system is considered to be unstable. A suitable MATLAB program was used to predict the stability conditions of the pump structure vibration. The present research focuses on fluid pump problems, namely, the role played by damping coefficient C, damping factor

... Show More
View Publication Preview PDF
Publication Date
Tue Aug 30 2016
Journal Name
Mechanical Engineering
The Effect of Different Furrow Depths and Speeds of Machinary Units Using A Locally Assembled Combine Implement on Planting Maize
...Show More Authors

View Publication
Publication Date
Thu Sep 11 2025
Journal Name
Journal Of Baghdad College Of Dentistry
The effect of different finishing and polishing systems on surface roughness of new low polymerized composite materials (An in vitro study)
...Show More Authors

Background: Prophylaxis methods are used to mechanically remove plaque and stain from tooth surfaces; such methods give rise to loss of superficial structure and roughen the surface of composites as a result of their abrasive action. This study was done to assess the effect of three polishing systems on surface texture of new anterior composites after storage in artificial saliva. Materials and methods: A total of 40 Giomer and Tetric®N-Ceram composite discs of 12 mm internal diameter and 3mm height were prepared using a specially designed cylindrical mold and were stored in artificial saliva for one month and then samples were divided into four groups according to surface treatment: Group A (control group):10 specimens received no surfa

... Show More
View Publication Preview PDF
Publication Date
Sun Mar 02 2008
Journal Name
Baghdad Science Journal
The Spectroscopic Behaviour of Rhodamine 6G in Liquid and Solid Solutions
...Show More Authors

Absorption, fluorescence, quantum yield and lifetime of rhodamine 6G in chloroform, methanol and dimethyl sulfoxide were measured. From a comparison of these quantities, with those for solid solutions (solid solutions are obtained by mixing constant volume proportions of dye at a concentration of 1*10-4M/l with different volume proportions from the concentrated solution of polymer in chloroform and dimethyl sulfoxide). The results showed that the addition of polymer to liquid concentrated solutions (1*10-4M/l )of rhodamine 6G dye from expecting [which leading to development active medium for laser dye at high concentration] increase the spectra shift toward high energies, and the luminescence quantum yield but decreasing radiative lifetim

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Fri Sep 15 2023
Journal Name
Journal Of Baghdad College Of Dentistry
Reliability of the multipeg™ transducer in measuring dental implant stability by using a resonance frequency analysis device (Osstell®): An observational clinical study
...Show More Authors

Background: Measuring implant stability is an important issue in predicting treatment success. Dental implant stability is usually measured through resonance frequency analysis (RFA). Osstell® RFA devices can be used with transducers (Smartpeg™) that correspond to the implants used as well as with transducers designed for application with Penguin® RFA devices (Multipeg™). Aims: This study aims to assess the reliability of a MultiPeg™ transducer with an Osstell® device in measuring dental implant stability. Materials and Methods: Sixteen healthy participants who required dental implant treatment were enrolled in this study. Implant stability was measured by using an Osstell® device with two transducers, namely, Smartpeg™ and M

... Show More
View Publication Preview PDF
Scopus (2)
Crossref (2)
Scopus Crossref
Publication Date
Sat Jun 07 2025
Journal Name
Intelligent Service Robotics
Grasping Stability of a Robotic Gripper with Frictional Self-Locking Mechanism
...Show More Authors

The grasping stability of robotic manipulators is crucial to enable autonomous manipulation in an environment where robots are facing obstacles in their route, where abrupt changes in the robot’s speed are induced. These speed variations will produce forces affecting the robotic manipulator, hence its grasping stability. In this research, the grasping stability of a robotic manipulator that functions according to a frictional self-locking mechanism is investigated statically and dynamically. Both theoretical and experimental results showed that the grasped object size, weight, and its orientation inside the gripper have a great effect on grasping stability. Both the theoretical and experimental results indicated that the grasping object p

... Show More
View Publication
Scopus Clarivate Crossref
Publication Date
Wed Jul 04 2012
Journal Name
مجلة العلوم التربوية والنفسية
The effect of a teaching program on oral classroom communication skills in the performance of practical education students at the College of Education, Bin Al-Haytham.
...Show More Authors

Preview PDF
Publication Date
Tue Oct 01 2024
Journal Name
The Saudi Dental Journal
Different pulp capping agents and their effect on pulp inflammatory response: A narrative review
...Show More Authors

View Publication
Scopus (3)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Fri Jan 01 2016
Journal Name
Journal Of Cosmetics, Dermatological Sciences And Applications
Treatment of Acute Cutaneous Leishmaniasis by Oral Zinc Sulfate and Oral Ketocanazole Singly and in Combination
...Show More Authors

View Publication
Crossref (7)
Crossref
Publication Date
Thu Sep 11 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Oral manifestation biochemical and IgA analysis of saliva in hyperthyroid (Grave’s disease) patients(Comparative study)
...Show More Authors

Background: Hyperthyroidism occurs due to over production of thyroid hormones, one types of hyperthyroidism was Graves, disease. Hyperthyroidism is characterized by high level of serum thyroxin, triiodothyronine and low level of thyroid stimulated hormones. Material and Methods: fifty two hyperthyroid patients, thirty patients under treatment with carbimazole and other twenty two patients under treatment with radioactive iodine, and sixty healthy control group. The average salivary flow rate was calculated as ml/5mint.The concentration of calcium, potassium, and total protein were determined in the salivary supernatant sample. This is done through different biochemical tests. Determination of salivary IgA is done by ELIZA. Results: The most

... Show More
View Publication Preview PDF