Preferred Language
Articles
/
bijps-559
A Study on the Stability of Different Frusemide Liquid Dosage Formulas: Oral Solution, Syrup, Elixir, Suspension and Emulsion
...Show More Authors

The present study aim at preparing frusemide in liquid form suitable for oral use. This is achieved through preparing different liquid forms of frusemide. The frusemide liquid is prepared in the following forms: oral solution, syrup and elixir with intensity of 1, 0.4 and 0.8% weight /volume respectively and in combination with potassium carbonate, polysorbate 80, alcohol and phosphate buffer solution of pH8 to dissolve the frusemide in the above mentioned forms. The different forms of the prepared medicine have been stored in glass bottles that can provide protection against light and at 40, 50, 600C for four months. Besides the pH has been checked to decide the period of validity. The results show that the expiration date of frusemide have lasted for 1.8, 1.07 and 1.22 years respectively for the oral solution, the syrup and the elixir. The suspensions of frusemide are formulated in combination with the following: polyvinyl pyrolidine, xanthan gum, the combination of (xanthan gum and sodium carboxymethyl cellulose), the combination of (xanthan: methyl cellulose) and chitosan.  The formulas which give suitable release of the drug are chosen for assessment according to the following considerations: The rat of sedimentation and apparent zero order degradation constant at 250C. In conclusion, it is found the best formula is that which includes poly vinylpyrolidine, tween20, glycerol, sorbitol, cocoa syrup and parabens at pH7. the fluidity of this chosen formula is psendoplastic type and its validity has lasted for about three years. The emulsion of frusemide is also prepared extemporaneously by using the commercial frusemide tablets in combination with acacia and olive oil. This should be consumed within 45 days of the date of production.

Key word: frusemide, elixir, suspension, emulsion.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Dec 12 2018
Journal Name
Iraqi National Journal Of Nursing Specialties
Evaluation of Acute Flaccid Paralysis Surveillance System's Structure at Al-Russafa Health Directorate in Baghdad City
...Show More Authors

Objective: evaluation of Acute Flaccid Paralysis Surveillance (AFP) System's Structure at Al-Russafa Health directorate in Baghdad City. Methodology: descriptive study using evaluation approach conducted to measure the efficiency of AFP Surveillance System structure for period from November 27th 2014 to June 30th 2015. The study adopted the non-probability multi-stage sampling approach. As nineteen health facilities under surveillance are chosen and interview is conducted with a total of 50 health worker how are involved in the AFP Surveillance System. The data are gathered from sample by using question

... Show More
View Publication Preview PDF
Publication Date
Fri Aug 26 2022
Journal Name
Journal Of Research In Medical And Dental Science
Evaluation of Some Salivary Characteristics in Relation to Dental Caries among Children with Beta-Thalassemia Major
...Show More Authors

Publication Date
Tue Sep 26 2017
Journal Name
The Gulf Journal Of Oncology
Effects of cranberry-PACs against urinary problems associated with radiotherapy in iraqi patients with bladder carcinoma
...Show More Authors

Scopus (3)
Scopus
Publication Date
Thu Jun 15 2023
Journal Name
Bionatura
Copper-to-Zinc Ratio as an Inflammatory Marker in Serum of Iraqi Patients with Axial Spondyloarthritis
...Show More Authors

Axial spondyloarthritis (axSpA) is a chronic rheumatic inflammatory disease affecting mainly the spine and sacroiliac joints. Since the copper-to-zinc ratio (Cu/Zn) indicates an inflammatory response, the change in ratio is expected to correlate with axSpA. This study compared levels of Cu/Zn in the serum of axSpA patients. Serum samples were obtained from 53 patients with axSpA divided according to biological treatment into cohorts A and B, and 28 healthy control as cohort C. Serum levels of Cu and Zn were determined first by a fully automated chemistry analyzer TC-Matrix Plus, then the ratio was obtained. The elevated serum Cu concentration means of cohort B (189.32 ± 13.808 µg/dL) compared to cohort A (168.85 ± 7.244 µg/dL) a

... Show More
View Publication
Scopus (2)
Scopus Crossref
Publication Date
Fri Jan 01 2016
Journal Name
Asian Journal Of Chemistry
Zwitterionic Ion Chromatography of Dansyl Amino Acids with 4-Vinylbenzyl Dimethyl Ammonio Pentanesulfonate as Stationary Phase
...Show More Authors

View Publication
Scopus (32)
Crossref (5)
Scopus Crossref
Publication Date
Tue Dec 22 2020
Journal Name
Lecture Notes In Civil Engineering
Geometric Nonlinear Synthetic Earthquake Analysis of Base Isolated Tall Steel Buildings Under Site-Specific Seismic Loading
...Show More Authors

View Publication
Scopus (2)
Crossref (1)
Scopus Crossref
Publication Date
Fri Nov 09 2018
Journal Name
Iraqi National Journal Of Nursing Specialties
Assessment of Nurses’ Knowledge Regarding Oxytocin Administration during Labor at Maternity Hospitals in Al-Kut City
...Show More Authors

Objectives of the study: To assess nurses knowledge regarding oxytocin administration during labor and
delivery in maternity hospitals, and to find out the relationship between nurses knowledge and studied
variables (age, level of education, work times (shift) experience year, training course in nursing field).
Methodology: Descriptive analytic study was conducted on non-probability sample (convenient) of (70) nurses
to assess nurse’s knowledge related to oxytocin administration. The study is conducted at Al- kut Hospital for
Gynecology Obstetrics and Pediatrics and Al- Zahraa Teaching Hospital during periods 5th February to 24th
April 2013, A questionnaire was used as a tool of data collection to fulfill with objecti

... Show More
View Publication Preview PDF
Publication Date
Fri Dec 30 2016
Journal Name
International Journal Of Applied Chemistry
Spectrophotometric Determination of Co(II) by Using Ethyl Cyano(2-Methyl Carboxylate Phenyl Azo Acetate) (ECA)
...Show More Authors

A new simple and sensitive spectrophotometric method for the determination of trace amount of Co(II) in the ethanol absolute solution have been developed. The method is based on the reaction of Co(II) with ethyl cyano(2-methyl carboxylate phenyl azo acetate) (ECA) in acid medium of hydrochloric acid (0.1 M) givining maximum absorbance at ((λmax = 656 nm). Beer's law is obeyed over the concentration range (5-60) (μg / ml) with molar absorptivity of (1.5263 × 103 L mol-1 cm-1) and correlation coefficient (0.9995). The precision (RSD% ˂ 1%). The stoichiometry of complex was confirmed by Job's method which indicated the ratio of metal to reagent is (2:1). The studied effect of interference elements Zn(II), Cu(II), Na(I), K(I), Ca(II) and Mg

... Show More
Preview PDF
Publication Date
Thu Oct 10 2024
Journal Name
Al-mustansiriyah Journal Of Arts
Strategies for Achieving an Equivalent Level of Appellation in Arabic Tourist Texts as Translated into English
...Show More Authors

Publication Date
Mon Sep 15 2014
Journal Name
Journal Of Clinical And Biomedical Sciences
Detection of EGFR Mutations in Bronchial Wash from Iraqi patients with nonsmall Cell Lung Cancer (NSCLC)
...Show More Authors

Background: Non-small cell lung cancer (NSCLC) is caused of 85% of all lung cancers. Among the most important factors for lung tumor growth and proliferation are the tyrosine kinase receptors that coded by the epidermal growth factor recep-tor (EGFR) gene. Activation of EGFR ultimately leads to developing of lung cancer. The present study was undertaken with an objective to detect EGFR mutations in bronchial wash from Iraqi patients with NSCLC before treatment. Methods: DNA was extracted from bronchial wash samples collected from 50 patients with NSCLC by using a Qiamp DNA Mini Kit (Qiagen, Hilden, Germany). Then, EGFR mutations were determined by using real-time RCR combined with two technologies, Amplification Refractory Mutation System (

... Show More
Crossref