Preferred Language
Articles
/
bijps-549
The Safety Profile of Single Daily Dose of Aminoglycosides in Comparison with Multiple Daily Dose
...Show More Authors

To overcome  the  problems  which  associated  with  the standard  multiple  daily  doses (MDD)

of aminoglycosides (AGs) like high incidence of toxicity(nephrotoxicity, ototoxicity)(5-25%) and high cost, an alternative approach was developed which was single daily dose (SDD).This new regimen was designed to maximize bacterial killing by optimizing the peak concentration/minimum inhibitory concentration(MIC)ratio and to reduce the potential for toxicity. The study includes 75 patients selected randomly, 50 of them received SDD regimen of age range of 17-79 years and the remaining received MDD regimen of age range of 13-71 years. The study was designed to evaluate the safety of SDD regimen in comparison with MDD regimen. All the patients in SDD group received a constant dose of   5-mg/kg/day of gentamicin and 20mg/kg/day of amikacin with a drug administration interval based on estimated creatinine clearance(CLcr): if ≥60 ml//min every 24 hours (q24h), 59- 40 ml/ min every 36hours and 39- 30 ml/min every 48 hours.The calculated dose was diluted with 0.9% normal saline or 5% dextrose to 50-100 ml and given as intravenous infusion over 30-60 minutes. In SDD group , the mean length of therapy was 6.4±1.73  days .Gentamicin accounted for 96% of the aminoglycoside use, and the majority(58%) of patients received the drug every 24 hours.The 36- and -48 hours intervals were used for 34 and 8% of the population, respectively.While in MDD group , the mean length of therapy was 5.0±0.91 days. Gentamicin accounted for all (100%) of aminoglycoside use, and all of the patients received the drug every 8 hours. No clinically apparent ototoxicity and nephrotoxicity were observed in the patients in the SDD group, in contrast to the patients in MDD group, in whom 4 patients (16%) were developed nephrotoxicity and 1 patient (4%) was developed ototoxicity. The obtained results indicate that SDD regimen was safer through decreasing the incidence of both nephrotoxicity and ototoxicity.For statistical analysis, ANOVA test was used with P<0.01.Each mean was expressed as mean±SEM(Standard Error of Mean).

Key words: Aminoglycosides, Single Daily Dose, Nephrotoxicity and Ototoxicity.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Dec 01 2022
Journal Name
Baghdad Science Journal
Comparison between RSA and CAST-128 with Adaptive Key for Video Frames Encryption with Highest Average Entropy
...Show More Authors

Encryption of data is translating data to another shape or symbol which enables people only with an access to the secret key or a password that can read it. The data which are encrypted are generally referred to as cipher text, while data which are unencrypted are known plain text. Entropy can be used as a measure which gives the number of bits that are needed for coding the data of an image. As the values of pixel within an image are dispensed through further gray-levels, the entropy increases. The aim of this research is to compare between CAST-128 with proposed adaptive key and RSA encryption methods for video frames to determine the more accurate method with highest entropy. The first method is achieved by applying the "CAST-128" and

... Show More
View Publication Preview PDF
Scopus (8)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Thu Jul 01 2021
The spontaneous emission performance of a quantum emitter coupled to a hybrid plasmonic waveguide with specified output polarization for on-chip plasmonic single-photon source
...Show More Authors

Scopus (4)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Tue May 11 2021
Journal Name
Photonics And Nanostructures - Fundamentals And Applications
The spontaneous emission performance of a quantum emitter coupled to a hybrid plasmonic waveguide with specified output polarization for on-chip plasmonic single-photon source
...Show More Authors

Nowadays, most of the on-chip plasmonic single-photon sources emit an unpolarized stream of single photons that demand a subsequent polarizer stage in a practical quantum cryptography system. In this paper, we numerically demonstrated the coupling of the light emitted from a quantum emitter (QE) at 700 nm wavelength to the propagation mode supported by an on-chip hybrid plasmonic waveguide (HPW) polarization rotator. Our results proved that the light emitted is linearly polarized at 0º, 45º/−45º, and 90º with propagation lengths of 5 μm, 3.3 μm, and 3.9 μm, respectively. Moreover, high power-conversion efficiency was obtained from an applied transverse magnetic (TM) mode (0º-polarization) to a transverse electric (TE) (90º-polari

... Show More
View Publication
Scopus (4)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Sun Sep 05 2010
Journal Name
Baghdad Science Journal
Statistical Model for Polarization Mode Dispersion in Single Mode Fibers
...Show More Authors

As the bit rate of fiber optic transmission systems is increased to more than , the system will suffer from an important random phenomena, which is called polarization mode dispersion. This phenomenon contributes effectively to: increasing pulse width, power decreasing, time jittering, and shape distortion. The time jittering means that the pulse center will shift to left or right. So that, time jittering leads to interference between neighboring pulses. On the other hand, increasing bit period will prevent the possibility of sending high rates. In this paper, an accurate mathematical analysis to increase the rates of transmission, which contain all physical random variables that contribute to determine the transmission rates, is presen

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Jan 01 2011
Journal Name
Iraqi Journal Of Physics
Single Particle Level Density in a Harmonic – Oscillator Potential Well
...Show More Authors

The purpose of this paper is to study the properties of the
partial level density ( ) l g and the total level density g ( ),
numerically obtained as a l sum of ( ) l g up to 34 max l  , for
a Harmonic – Oscillator potential well. This method applied the
quantum – mechanical phase shift technique and concentrated
on the continuum region. Also a discussion of peculiarities of
quantal calculation for single particle level density of energy –
dependent potential

View Publication Preview PDF
Publication Date
Sun Jan 01 2023
Journal Name
Rawal Medical Journal
Procalcitonin Level In COVID-19 Patients: A single center study
...Show More Authors

Objective: The study the association of procalcitonin (PCT) and c-reactive protein (CRP) levels in COVID-19 patients and it's role as a guide in progress and management of those patients. Methodology: This cross-sectional study analyzed 200 CIOVID-19 patients in a single privet center in Baghdad, Iraq from January 1, 2021 to January 1, 2022. Demographic data like age, sex, and clinical symptoms were recorded. High sensitivity CRP and PCT in the serum were measured via dry fluorescence immunoassay (Lansionbio-China). Results: Out of 200 patients, 50 had moderate Covid and 150 had severe disease. Mean serum PCT levels was 0.039±0.05 ng/mL in the moderate group (range 0.011-0.067) and 0.43±0.21 ng/mL in the severe group (range 0.21

... Show More
View Publication
Scopus Crossref
Publication Date
Mon Mar 08 2021
Journal Name
Baghdad Science Journal
Performance quality of single and ?two stage solar concentrators
...Show More Authors

The performance of single and two stage solar concentrator were studied ' " The ratio of the primary to the secondary mirrors diameter is taking to be 0.5, depending on the theoretical calculation for the accumulated energy by the concentrator with ratio between 0.0 to 0.9. The design of the systems were designed and examined by using a ray-tracing program. The efficiency of the single and the two stage concentrators are calculated and compared with and without cooling systems.

View Publication Preview PDF
Publication Date
Tue Jun 30 2015
Journal Name
Al-khwarizmi Engineering Journal
Deflection Analysis of an Elastic Single Link Robotic Manipulator
...Show More Authors

Abstract

Robotics manipulators with structural flexibility provide an attractive alternative to rigid robotics manipulators for many of the new and evolving applications in robotics. In certain applications their use is unavoidable. The increased complexity in modeling and control of such manipulators is offset by desirable performance enhancements in some respects. In this paperthe single- link flexible robotics manipulator was designed and implemented from Perspex and designed with 0.5 m length , 0.02 m width and with 0.004 m thickness with mass located at the tip. There are four subsystems; motion, control, accelerometer and gyro and a host computer subsystem. The work principle of single-link robotics manipul

... Show More
View Publication Preview PDF
Publication Date
Mon Jul 10 2023
Journal Name
Journal Of Engineering
Design and Implementation of Single-Phase Boost PFC Converter
...Show More Authors

In this paper, a single-phase boost type ac-dc converter with power factor correction (PFC) technique is designed and implemented. A current mode control at a constant switching frequency is used as a control strategy for PFC converter. The PFC converter is a single-stage singleswitch boost converter that uses a current shaping technique to reshape the non-sinusoidal input current drawn by the bulky capacitor in the conventional rectifier. This technique should provide an input current with almost free-harmonics, comply with the IEC61000-3-2 limits, and a system operates with near unity power factor. The other function of the boost converter that should be
accomplished is to provide a regulated DC output voltage. The complete designed

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue Sep 01 2020
Journal Name
Journal Of Coloproctology
Epidemiological and prognostic single center study of anal carcinoma
...Show More Authors
Abstract<p> Background Anorectal carcinoma includes the anal margin, the anal canal, and the lower rectum. The incidences of anal tumors represent 1.4 % of all gastrointestinal tumors.</p><p> Patients and methods Our study is retrospective and was conducted at Baghdad Medical City. Patient’s data were collected from the medical records through a predesigned sheet that included the following information: demographic data, medical history, past-history, presenting symptoms, pathological data, and treatment details.</p><p> Results The median age was 49 years. As regard tumor extension, 85.71 % of patients had anal disease, while anorectal cancer was encount</p> ... Show More
View Publication
Scopus (8)
Crossref (6)
Scopus Crossref