Preferred Language
Articles
/
bijps-514
Bioequivalence of Two Formulations of Amoxicillin in Human Healthy Volunteers on (HPLC) Technique
...Show More Authors

Amoxicillin is commercially available in the form of capsules and tablets containing 250mg or 500mg for oral administration. It is also available in the form of suspension containing "25mg/ml” . Amoxicillin is presently used as the most common antibiotics .Ten healthy Human volunteers were characterized respected to their pharmacokinetic and bioavailability of two formulations of Amoxicillin from two sources of  industrial companies  after a single dose administration was given orally. A procedure is described for determination the concentration levels of Amoxicillin in human plasma of healthy volunteers using high performance liquid chromatography (HPLC) with reversed-phase isocratic column at low wave length of UV-visible detection "230nm". An efficient drug extraction procedure was used for the separation of Amoxicillin after simple extraction with cold methanol using ODS-C18-DB column. The pharmacokinetic 500mg of Amoxicillin capsule orally administrated treatment through 10 hours  has been examined.  The  Amoxicillin  was eluted  for "10.0 minutes" at flow Rate "1.5ml/min." and Temperature equal to 298 K .The retention time of Amoxicillin was observed at 7.0 minutes. The mean absolute recovery of Amoxicillin in blood plasma of all healthy volunteers were 94.1% at 1.0ppm, 102% at 5.0ppm, 103% at 10.0ppm 102% at 20ppm, 99.3% at 40ppm and 104% at 50ppm respectively. The assay showed excellent relationships between area under the curve ratios and drug concentration levels (P>0.002) .Oral Amoxicillin administration in ten healthy volunteers gave maximum concentration peak plasma at two hours and decline through ten hours. Treatment with Iraqi formulation Amoxicillin produced higher area under the curve “AUC” and maximum concentration “C (max)” of Amoxicillin than Indian formulation.

Key word: Amoxicillin, Bioequivalence, ODS -DB column.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Jan 12 2020
Journal Name
Technologies And Materials For Renewable Energy, Environment And Sustainability
The effect of doping process on the structural and optical properties of Ag2Se thin films.
...Show More Authors

Preview PDF
Publication Date
Sat Dec 01 2018
Journal Name
Al-khwarizmi Engineering Journal
The Effect of Walled Nano-Carbon on the Physical, Thermal and Mechanical Properties of Epoxy
...Show More Authors

The physical, the thermal and the mechanical properties of Nano-composites, that consisted of Polyprime EP epoxy that reinforced by multi-walled carbon nanotubes (MWCNTs), have been studied. Various loading ratios, 0.1, 0.5, and 1 wt. %of MWCNT shave been infused into epoxy by a magnetic stirrer and then the hardener mixed with the mthat supplied with the epoxy. All sample shave been cutting using CNC machine. Tensile test, three-point bending, hardness tests, lee's disk, differential scanning calorimetry, water absorption and dielectric and electrical conductivity test were utilized on unfilled, MWCNT-filled epoxy to identify the loading effect on the properties of materials. Scanning electron microscopy (SEM) was used to determine the

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Jan 25 2015
Journal Name
Geomechanics And Engineering
Improvement of bearing capacity of footing on soft clay grouted with lime-silica fume mix
...Show More Authors

View Publication
Scopus (45)
Scopus
Publication Date
Mon Jun 10 2013
Journal Name
International Journal Of Application Or Innovation In Engineering & Management (ijaiem)
The Effect of Annealing Temperature on the Optical Properties of CdS and CdS:Al Thin Films
...Show More Authors

Cadmium sulfide and Aluminum doped CdS thin films were prepared by thermal evaporation technique in vacuum on a heated glass substrates at 373K. A comparison between the optical properties of the pure and doped films was made through measuring and analyzing the transmittance curves, and the effect of the annealing temperature on these properties were estimated. All the films were found to exhibit high transmittance in the visible/ near infrared region from 500nm to 1100nm.The optical band gap energy was found to be in the range 2.68-2.60 eV and 2.65-2.44 eV for CdS and CdS:Al respectively , with changing the annealing temperature from room temperature to 423K.Optical constants such as refractive index, extinction coefficient, and complex di

... Show More
Publication Date
Tue Mar 28 2023
Journal Name
Iranian Journal Of Ichthology
Histological study of lingual papillae on the tongue of the adult Iraqi domestic cat, Felis
...Show More Authors

The results of this study showed that the tongue of the adult Iraqi domestic cat is divided into three regions of apex, body and root. The dorsal surface of all regions possesses five types of lingual papillae, two mechanical which are filiform and cylindrical papillae, while the other three types are taste papillae which are foliate, fungiform and circumvallate papillae, while these papillae are absent on its ventral surface. The histological examination of all tongue areas revealed that it consisted of three tunica, the tunica mucosa and the tunica submucosa (the lamina propria) and the tunica muscularis. The tunica mucosa consisted of the epithelial lining, which is a stratified squamous epithelial tissue covering the lingual papillae, a

... Show More
Preview PDF
Publication Date
Mon Sep 29 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Effect of certain chemical surface treatments on repair bond strength of some denture base materials
...Show More Authors

Background: Fracture of different types of acrylic denture base is a common problem associated with dental prosthesis. Studies suggested that the repair strength may be improved by several means including surface treatment with chemical agents. The aim of the study was to evaluate the effect of surface treatment with acrybond-bonding agent and monomer on fractured denture base in respect to transverse, tensile and shear bond strength and evaluation of the mode of failure by light microscope. Materials and methods: Two hundred seventy specimens were prepared and divided into 3 groups according to the material used (regular conventional, rapid simplified and high impact) heat cure acrylic. The specimen in each groups were prepared specificall

... Show More
View Publication Preview PDF
Publication Date
Mon Sep 29 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Effect of silica layer on bonding strength of thermoplastic nylon to cold cure acrylic resin
...Show More Authors

Background: The combination of thermoplastic nylon resin materials and auto polymerizing resin is necessary in some situation for repair and adjustment. This study evaluated shear bond strength between thermoplastic nylon material (flexible) and auto polymerizing acrylic resin subjected to holes and silica coated layer. Materials and Method: Forty five (45) specimens were prepared from flexible acrylic bonded to auto-polymerizing acrylic resin and divided into three groups according to the surface treatments as follows: Group A: 15 specimens of flexible acrylic bonded with cold-cure acrylic by holes. Group B: 15 specimens of flexible acrylic bonded with cold-cure acrylic by silica coated layer. Group C: 15 specimens of flexible acrylic bon

... Show More
View Publication Preview PDF
Publication Date
Mon Sep 29 2025
Journal Name
Journal Of Baghdad College Of Dentistry
The effects of unilateral premature loss of maxillary primary molars on the dental arch dimensions
...Show More Authors

Background: The aim of the study was to evaluate the amount of changes in the horizontal and vertical maxillary arch dimensions measurements following the premature loss of primary molars. Materials and methods: The sample consist of (50) children with unilateral prematurely extracted either first or second primary molars at the mixed dentition stage. Results and Conclusions: Results shows that there was an increase in the vertical incisor to canine distance (A) with both premature loss of first & second primary molars due to distal movement of primary canines and at the same time there were a significant loss of space in the extraction space with premature loss of second primary molar due to a mesial movement of maxillary first permanent

... Show More
View Publication Preview PDF
Publication Date
Tue Mar 21 2023
Journal Name
International Journal Of Professional Business Review
Analysis of the Impact of Six Sigma and Risk Management on Iraq's Energy Sector Metrology
...Show More Authors

Purpose: aims the study to show How to be can to enhance measurement management by incorporating a risk-based approach and the six sigma method into a more thorough assessment of metrological performance.   Theoretical framework: Recent literature has recorded good results in analyzing the impact of Six Sigma and risk management on the energy sector (Barrera García et al., 2022) (D'Emilia et al. 2015). However, this research came to validate and emphasize the most comprehensive assessment of metrological performance by integrating Risk management based approach and Six Sigma analysis.   Design/methodology/approach: This study was conducted in Iraqi petroleum refining companies. System quality is measured in terms of sigmas, and t

... Show More
Crossref
Publication Date
Thu Jun 01 2017
Journal Name
Iosr Journal Of Pharmacy And Biological Sciences
Effect of Nano Silicon Dioxide Addition on Some Properties of Heat Vulcanized Maxillofacial Silicone Elastomer
...Show More Authors

Abstract : Silicone elastomer is widely used as the material of choice for fabricating maxillofacial prosthesis. However, silicone properties are far from ideal; low tear strength, low tensile strength and insufficient elasticity are the most undesirable properties. The purpose of this study was to evaluate the effect of addition of nano SiO2filler on tear strength, tensile strength, elongation at break, hardness and color of Cosmesil M-511 HTV maxillofacial silicone elastomer. Nano SiO2was added to the silicone base in concentrations of 4%, 5% and 6% by weight. Silicone with 0% nano filler served as a control. Tear test was done according to ISO 34-1. Tensile and elongation test was done according to ISO 37. Shore A hardness test was done

... Show More
View Publication Preview PDF
Crossref (9)
Crossref