Preferred Language
Articles
/
bijps-422
Formulation and Evaluation of Bilayer Tablets Containing Immediate Release Aspirin Layer and Floating Clopidogrel Layer
...Show More Authors

Aspirin and clopidogrel are considered the most important oral platelets aggregation inhibitors. So it is widely used for treatment and prophylaxis of cardiovascular and peripheral vascular diseases related to platelets aggregation .In this study aspirin and clopidogrel were formulated together as floating bilayer tablet system. Three different formulas of 75 mg aspirin were prepared by wet granulation method as immediate release layer; different disintegrants used to achieve rapid disintegration. Formula with crosscarmellose as disintegrant achieve rapid disintegration was selected for preparation of bilayer tablet.

Different formulas of 75 mg clopidogrel were prepared as sustained release floating layer by wet granulation (effervescent ) method ;the physical and floating properties for compressed clopidogrel matrix were studied in addition to study the effect of polymer  concentration(HPMC) ,and its combination with ethyl cellulose and carbapol ,effect of different diluents and effect of increasing sodium bicarbonate amount on the release from compressed matrix .

Formula prepared with HPMC and EC in a ratio of 1:1 was capable to retard the release of clopidogrel for 6 hours in addition to its good floating behavior and therefore selected to prepare bilayer tablets in combination with selected aspirin layer.

The prepared bilayer tablets were further subjected to evaluation of their physical, floating properties and release behavior. Finally the kinetic study reflects acceptable shelf life for aspirin and clopidogrel.

Key words: Aspirin, Clopidogrel, Bilayer tablet, Floating tablet.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Mar 01 2022
Journal Name
Iraqi Journal Of Physics
Effect of pH on the Structural and Optical Properties of Cadmium oxide Thin Films Prepared Using the Successive Ionic Layer Adsorption and Reaction (SILAR) Method
...Show More Authors

Cadmium oxide (CdO) thin films were deposited using the sequencing ion layer adsorption and reaction (SILAR) method. In this study, the effect of the pH value of an aqueous solution of cadmium acetate at a concentration of 0.2 mol of the cadmium oxide film was determined. The solution source for the cadmium oxide film was cadmium ions and an aqueous ammonia solution. The CdO films were deposited on glass substrates at a temperature of 90 ℃. The cadmium oxide film thickness was determined by the weight difference method at pH values ​​(7.2, 8.2). X-ray diffraction (XRD) and scanning electron microscopy (SEM) showed that the size of the crystals increased with the increase in the solution (pH). While the UV-visible spectra of the fil

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Jan 01 2021
Journal Name
Aip Conference Proceedings
Deposited Cu (In, Ga) Se2 (CIGS) by spin-coating technique as an absorber layer of solar-cells
...Show More Authors

Cu (In, Ga) Se2 (CIGS) nano ink were synthesized from molecular precursors of CuCl, In Cl3, GaCl3 and Se metal heated to 240 °C for 1 hour in N2-atmosphere to form CIGS nanocrystal ink, Thin films were deposited onto Au/soda-lime glass (SLG) substrates. This work focused on CIGS nanocrystals, including their synthesis and application as the active light absorber layer in photovoltaic devices (PVs). This approach, using spin-coating deposition of the CIGS light absorber layers (75 mg/ml and 150 nm thickness), without high temperature selenization, has enabled up to 1.398 % power conversion efficiency under AM 1.5 solar illumination. X-ray diffraction (XRD) studies show that the structural formation of CIGS chalcopyrite structure. The mo

... Show More
View Publication
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Mon Jan 01 2024
Journal Name
Ieee Access
Dual-Layer Compressive Sensing Scheme Incorporating Adaptive Cross Approximation Algorithm for Solving Monostatic Electromagnetic Scattering Problems
...Show More Authors

View Publication
Scopus (1)
Scopus Clarivate Crossref
Publication Date
Wed Nov 11 2020
Journal Name
The Abu Dhabi International Petroleum Exhibition & Conference, Abu Dhabi, Uae, November 2020. Paper Number: Spe-203249-ms
Investigating Geomechanical Considerations on Suitable Layer Selection for Hydraulically Fractured Horizontal Wells Placement in Tight Reservoirs
...Show More Authors

The instant global trend towards developing tight reservoir is great; however, development can be very challenging due to stress and geomechanical properties effect in horizontal well placement and hydraulic fracturing design. Many parameters are known to be important to determine the suitable layer for locating horizontal well such as petrophysical and geomechanical properties. In the present study, permeability sensitivity to stress is also considered in the best layer selection for well placement. The permeability sensitivity to the stress of the layers was investigated using measurements of 27 core sample at different confining stress values. 1-D mechanical earth model (MEM) was built and converted to a 3-D full-field geomechanical mode

... Show More
View Publication
Publication Date
Wed Jan 01 2020
Journal Name
Society Of Petroleum Engineering
Investigating geomechanical considerations on suitable layer selection for hydraulically fractured horizontal wells placement in tight reservoirs
...Show More Authors

Scopus (8)
Scopus
Publication Date
Mon Jan 01 2024
Journal Name
Journal Of Materials Science: Materials In Electronics
Influence of cobalt doping on structural and optical properties of copper oxide expected as an inorganic hole transport layer for perovskite solar cell
...Show More Authors

View Publication
Scopus (10)
Crossref (9)
Scopus Clarivate Crossref
Publication Date
Thu Feb 12 2026
Journal Name
Journal Of Baghdad College Of Dentistry
The effect of smear layer on push-out bond strength to dentin of Bioceramic sealer (In vitro study)
...Show More Authors

Background: Sealers should demonstrate adhesive properties to dentin, decreasing the chance of endodontic treatment failure. Increased adhesive properties to dentin may lead to greater strength of the restored tooth, which may provide greater resistance to tooth fracture and clinical longevity of an endodontically treated tooth. The aim of this study was to evaluate the shear bond strength of Bioceramic iRoot SP sealer, AH plus sealer and Apexit plus sealer in absence or presence of smear layer using push out bond strength test. Materials and Methods: Sixty straight single roots of the mandibular premolars were selected for this study. All canals were instrumented using ProTaper rotary instruments to achieve tapered canal walls, instrumenta

... Show More
View Publication Preview PDF
Publication Date
Wed Jan 01 2020
Journal Name
Ieee Access
Smart Routing Management Framework Exploiting Dynamic Data Resources of Cross-Layer Design and Machine Learning Approaches for Mobile Cognitive Radio Networks: A Survey
...Show More Authors

View Publication
Scopus (20)
Crossref (21)
Scopus Clarivate Crossref
Publication Date
Thu Feb 01 2018
Journal Name
Iosr Journal Of Pharmacy And Biological Sciences
Synthesis, Characterization of Organic Derivatives Containing Heterocyclic Rings and Evaluation Their Antibacterial Activity
...Show More Authors

Schiff bases (Sh1-Sh3) have been synthesized (p-aminophenol) was condensed with different aromatic aldehyde in ethanol inthe presence of glacial acetic acid as catalyst. These Schiff bases on treatment with monochloroacetyl choride gave 3-chloro-1-(4-hydroxyphenyl)-4-(substituted)azetidin-2-one(Az4-Az6), with αmercaptoacetic acid gave 3-(4-hydroxyphenyl)-2-( substituted)thiazolidin-4-one (Th7-Th9) and with anthranilic acid gave 3-(4-hydroxyphenyl)-2(substituted)-2,3-dihydroquinazolin-4(1H)-one (Qu10-Qu12). The purity of the derivatives was confirmed by TLC. The some compoundsidentify by (FT-IR and1H, 13C-NMR) data. Some of derivatives were evaluated activity against several microbesto determine ability to inhibit bacterial in some h

... Show More
View Publication Preview PDF
Publication Date
Wed Dec 01 2021
Journal Name
Baghdad Science Journal
Improvement of the Fault Tolerance in IoT Based Positioning Systems by Applying for Redundancy in the Controller Layer
...Show More Authors

In recent years, the positioning applications of Internet-of-Things (IoT) based systems have grown increasingly popular, and are found to be useful in tracking the daily activities of children, the elderly and vehicle tracking. It can be argued that the data obtained from GPS based systems may contain error, hence taking these factors into account, the proposed method for this study is based on the application of IoT-based positioning and the replacement of using IoT instead of GPS.  This cannot, however, be a reason for not using the GPS, and in order to enhance the reliability, a parallel combination of the modern system and traditional methods simultaneously can be applied. Although GPS signals can only be accessed in open spaces, GP

... Show More
View Publication Preview PDF
Scopus (4)
Crossref (3)
Scopus Clarivate Crossref