Preferred Language
Articles
/
bijps-409
Preparation and Evaluation of Liquid and Solid Self-Microemulsifying Drug Delivery System of Mebendazole
...Show More Authors

The aim of present study was to develop solid and liquid  self-microemulsifying drug  delivery system of poorly water soluble drug mebendazole using Aerosil 200 as solid carrier.  Microemulsions are clear, stable, isotropic liquid mixtures of oil, water and surfactant, frequently in combination with a co-surfactant having droplet size range usually in the range of 20-250 nm. Oleic acid, tween 80 and polypropylene glycol were selected as oil, surfactant and co-surfactant respectively and for preparation of stable SMEDDS, micro emulsion region was identified by constructing pseudo ternary phase diagram containing different proportion of surfactant: co-surfactant (1:1, 2:1 and 3:1), oil and water. In brief S/ CoS mix means surfactant to co-surfactant and oil were mixed at ratio of 1:9, 2:8, 3:7, 4:6, 5:5, 6:4, 7:3, 8:2 and 9:1 manner. To the resultant mixtures, water was added drop wise till the first sign of turbidity in order to identify the end point and after equilibrium; if the system became clear then the water addition was continued. Prepared optimised formula of microemulsion was evaluated for SEM, particle size analysis, polydispersity index, phase separation, viscosity determination, zeta potential, in- vitro dissolution study and in- vivo studies. The optimized microemulsion was converted into solid form by Spray Drying technique by using Aerosil 200 as solid carrier. Prepared SMEDDS was characterized for same parameters as that of microemulsion. Solid SMEDDS of mebendazole prepared using Aerosil 200 by spray drying technique showed good drug content uniformity. After reconstitution it formed microemulsion with micrometric range. In-vitro drug release and in-vivo plasma drug concentration of microemulsion and SMEDDS was much higher than that of marketed praparation. Hence lipid based drug delivery system may efficiently formulate microemulsion and it can be solidified easily by spray drying technique which enhances dissolution rate and thus concomitantly bioavailability. In conclusion ,self micro emulsifying drug delivery system has become promising tool to overcome shortcomings associated with conventional delivery.

Kew words: Self-microemulsifying drug  delivery system, Microemulsion, Mebendazole.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Oct 06 2014
Journal Name
Journal Of Educational And Psychological Researches
Impulsive behavior among Kindergarten children and its relation ship with some variables preparation
...Show More Authors

Quite anumber of parents and educators of this behavior,which is characterized by exaggerating locomotor activity and impulsivity and recklessness and the difficulty of continuing the status of certain bodily more than one minute ,and the difficulty of waiting to meet aparticular need or desire,it also characterized by thos meddling children the affairs of others and increased their  chatter does not seem the case when you listen to talk to them and they characterized by  weak self-confidence and are more solid and seem un able to keep ther responses because of the severity of anxiety .The research aims to know impulsive behavior among kindergartens children and its relation ship with some variables, and the sa

... Show More
View Publication Preview PDF
Publication Date
Fri Dec 30 2011
Journal Name
Al-kindy College Medical Journal
Comparison Between Mechanical and Non Mechanical Bowel Preparation Prior To Elective Colorectal Surgery
...Show More Authors

Background: Bowel preparation prior to
colonic surgery usually includes antibiotic
therapy together with mechanical bowel
preparation which may cause discomfort to the
patients, prolonged hospitalization and water
& electrolyte imbalance.
Objective: to assess whether elective colon
and rectal surgery may be safely performed
without preoperative mechanical bowel
preparation.
Method: the study includes all patients who
had elective large bowel resection at Medical
City – Baghdad Teaching Hospital between
Feb, 2007 to Jan, 2010. Emergency operations
were not included. The patients were randomly
assigned to the 2 study groups (with or without
mechanical bowel preparation.
Results: A to

... Show More
View Publication Preview PDF
Publication Date
Mon Feb 04 2019
Journal Name
Iraqi Journal Of Physics
Chemical sensor based on a solid-core photonic crystal fiber interferometer
...Show More Authors

Photonic crystal fiber interferometers are used in many sensing applications. In this work, an in-reflection photonic crystal fiber (PCF) based on Mach-Zehnder (micro-holes collapsing) (MZ) interferometer, which exhibits high sensitivity to different volatile organic compounds (VOCs), without the needing of any permeable material. The interferometer is robust, compact, and consists of a stub photonic crystal fiber of large-mode area, photonic crystal fiber spliced to standard single mode fiber (SMF) (corning-28), this splicing occurs with optimized splice loss 0.19 dB In the splice regions the voids of the holey fiber are completely collapsed, which allows the excitation and recombination of core and cladding modes. The device reflection

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Jun 01 2009
Journal Name
Journal Of Economics And Administrative Sciences
Use of lower squares and restricted boxes In the estimation of the first-order self-regression parameter AR (1) (simulation study)
...Show More Authors

Use of lower squares and restricted boxes
In the estimation of the first-order self-regression parameter
AR (1) (simulation study)

View Publication Preview PDF
Crossref
Publication Date
Sun Mar 30 2014
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Estimation Liquid Permeability Using Air Permeability Laboratory Data
...Show More Authors

Permeability data has major importance work that should be handled in all reservoir simulation studies. The importance of permeability data increases in mature oil and gas fields due to its sensitivity for the requirements of some specific improved recoveries. However, the industry has a huge source of data of air permeability measurements against little number of liquid permeability values. This is due to the relatively high cost of special core analysis.
The current study suggests a correlation to convert air permeability data that are conventionally measured during laboratory core analysis into liquid permeability. This correlation introduces a feasible estimation in cases of data loose and poorly consolidated formations, or in cas

... Show More
View Publication Preview PDF
Publication Date
Fri Jul 21 2023
Journal Name
Journal Of Engineering
Bubble Size Distribution In Gas-Liquid Dispersion Column
...Show More Authors

The present work investigates the effect of; superficial air velocities of: 1, 3, and 6 cm/s for two types of perforated distributor on hydrodynamic characteristic in a gas-liquid dispersion column of; air-water, and airaqueous-n-propanol solution. Bubble distribution, gas holdup, and power consumption are parameters take in consideration. Experimental work was carried out in perspex column of 8.5 cm inside diameter and 1.5 m height. Two types of bubble generator (perforated plate) were fixed at the bottom of the column; plate A (99 holes of 0.5 mm diameter and free area of 0.34%), plate B (20 holes of 1.5 mm diameter and free area of 0.62%). Photographic technique was used to measure the bubble parameters. The experimental results were

... Show More
View Publication Preview PDF
Publication Date
Fri May 10 2019
Journal Name
Research Journal Of Chemistry And Environment
Solid Phase Extraction of Theophylline in Aqueous Solutions by Modified Magnetic Iron Oxide Nanoparticles as an Extractor Material and Spectrophotometry Technique for the Determination
...Show More Authors

new, simple and fast solid-phase extraction method for separation and preconcentration of trace theophylline in aqueous solutions was developed using magnetite nanoparticles (MIONPs) coated with aluminium oxide (AMIONPs) and modified with palmitate (P) as an extractor (P@AMIONPs). It has shown that the developed method has a fast absorbent rate of the theophylline at room temperature. The parameters that affect the absorbent of theophylline in the aqueous solutions have been investigated such as the amount of magnetite nanoparticle, pH, standing time and the volume, concentration of desorption solution. The linear range, limit of quantification (LOQ) and limit of detection (LOD) for the determination of theophylline were 0.05-2.450 μg mL-

... Show More
View Publication
Publication Date
Tue Jul 28 2020
Journal Name
Iraqi Journal Of Science
Charge Transfer Spectrophotometric Determination of Metronidazole in Pharmaceutical Formulations by Normal and Reverse Flow Injection Analysis Coupled with Solid-Phase Reactor Containing Immobilized FePO4
...Show More Authors

     Two rapid, simpleand sensitive flow injection methods were developed for the estimation of metronidazole (MRZ) in pharmaceutical formulations. The proposed methods were based on charge transfer reaction between metol (N-methyl-p-aminophenol sulfate) as a Ï€-acceptorand reduced MRZ as an n-donor to produce a blue colored chargetransfer complex. Method A depends on the reaction of reduced MRZ with metol (MT) in the presence of NaIO4 using two lines manifold to form blue colored product exhibiting absorption maxima at 700 nm.While method B depends on charge transfer reaction of reduced MRZ with MT in presence of a solid phase reactorcontainingfixedFePO4 on cellulose acetateusing reverse flow

... Show More
View Publication Preview PDF
Scopus (8)
Crossref (3)
Scopus Crossref
Publication Date
Mon May 22 2023
Journal Name
Journal Of Optics
The influence of gold nanoparticles on electro-optical properties of nematic liquid crystal
...Show More Authors

View Publication
Scopus (1)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Sun Mar 30 2008
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Pyrolysis of High-density Polyethylene for the Production of Fuel-like Liquid Hydrocarbon
...Show More Authors

Pyrolysis of high density polyethylene (HDPE) was carried out in a 750 cm3 stainless steel autoclave reactor, with temperature ranging from 470 to 495° C and reaction times up to 90 minute. The influence of the operating conditions on the component yields was studied. It was found that the optimum cracking condition for HDPE that maximized the oil yield to 70 wt. % was 480°C and 20 minutes. The results show that for higher cracking temperature, and longer reaction times there was higher production of gas and coke. Furthermore, higher temperature increases the aromatics and produce lighter oil with lower viscosity.

View Publication Preview PDF