Preferred Language
Articles
/
bijps-367
Bioequivalence and Pharmacokinetics Comparison of Two Formulations of Extended-Release Pentoxifylline Tablets in Healthy Subjects after Fasting and Fed Conditions
...Show More Authors

The pharmacokinetics and bioequivalence of a newly developed extended-released (ER) tablet containing 400 mg pentoxifylline as a test product was compared with the reference brand product Trental® 400 mg ER tablet produced by Sanofi-Aventis. Two separate studies were conducted simultaneously. The first study was conducted under fasting condition, whereas, the second study was conducted under fed condition; using the same batches of the test and reference products in both studies. In each study, both products were administered to 32 healthy male adult volunteers applying a single-dose, two-treatment, two-period, two-sequence, randomized crossover design with one-week washout period between dosing. Twenty two blood samples were withdrawn from each volunteer over 24 hours period.  Pentoxifylline concentrations were determined in plasma by a validated HPLC method according to FDA Bioanalytical Method Validation Guidance using UV detection and chloramphenicol as internal standard. The lower limit of quantitation of the drug in plasma was 5 ng/ml and the upper limit of quantitation was 500 ng/ml. From the plasma concentration-time data of each individual, the pharmacokinetic parameters; Cmax,  AUC0-t, AUC0-Â¥, Cmax/AUC0-Â¥, Tmax, lZ & T0.5; were calculated applying non-compartmental analysis. Data of the test and reference products were statistically analyzed to test for bioequivalence of the two products, using criteria of FDA and EMEA Guidance.  The pharmacokinetic parameters mentioned above were statistically analyzed by descriptive statistics, ANOVA test and 90% Confidence Interval (CI). ANOVA test involved the calculation of the effects of: treatment, period, sequence and subjects nested in sequence. According to the above guidance, the primary pharmacokinetic parameters used for bioequivalence testing, namely Cmax, AUC0-t and AUC0-Â¥ were also statistically analyzed by ANOVA & CI tests using the corresponding Ln-transformed values. The mean values  Cmax,  AUC0-t , AUC0-Â¥ , Cmax/AUC0-Â¥ , Tmax, lZ & T0.5 for the test formula obtained from the fasting study  were; 144.4 ng/ml,  845.4 ng.hr/ml, 868.4 ng.hr/ml, 0.186 hr-1, 3.29 hr, 0.561 hr-1 and 1.65 hr, respectively; and the mean values of these parameters for the reference formula were; 150.0 ng/ml,  871.1 ng.hr/ml, 893.7 ng.hr/ml, 0.177 hr-1, 3.70 hr, 0.558 hr-1 and 1.59 hr,  respectively.  The mean values of the above mentioned parameters for the test formula obtained from the fed study were; 157.8 ng/ml, 826.5 ng.hr/ml, 853.8 ng.hr/ml, 0.198 hr-1, 5.4 hr, 0.458 hr-1 and 2.06 hr, respectively; and the mean values of these parameters for the reference formula were; 162.1 ng/ml, 869.7 ng.hr/ml, 894.8 ng.hr/ml, 0.196 hr-1, 4.1 hr, 0.525 hr-1 and 1.80 hr, respectively.  Based on criteria of FDA and   EMEA Guidance on Bioavailability and Bioequivalence, the results of the fasting and fed studies demonstrated bioequivalence of the two products under either condition. Accordingly, it is concluded that the newly developed ER tablet containing 400 mg pentoxifylline is bioequivalent to Trental® 400 mg ER tablet produced by Sanofi-Aventis.

Keywords: Pentoxifylline, Pharmacokinetics, Bioequivalence.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Jun 15 2021
Journal Name
Al-academy
The Utilization of Arabic Calligraphy to Inspire Modern Arabic Type Designs: ربا حسن أبو حسنة
...Show More Authors

Arabic calligraphy is one of the greatest achievements of Islamic art. The visual form of Arabic calligraphy is the primary means of presenting ideas and messages for expressive communication in Arabic typefaces. Emerging computer technology with calligraphy is essential for effective visual designs; however, traditional typefaces are insufficient in number and quality to fulfill the requirements of the current Saudi industry. Thus, this research investigates the processes followed by graphic designers to create modern Arabic type designs inspired by Arabic calligraphy, and presents the characteristics of Arabic calligraphy. The research implemented a mixed experimental and descriptive method, exploring 10 typefaces designed by professio

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Dec 11 2017
Journal Name
Al-khwarizmi Engineering Journal
ptimization the Parameters of Magnetic Abrasive Process Using Taguchi Method to Improve the Surface Roughness
...Show More Authors

Abstract  

Magnetic abrasive finishing (MAF) process is one of non-traditional or advanced finishing methods which is suitable for different materials and produces high quality level of surface finish where it uses magnetic force as a machining pressure. A set of experimental tests was planned according to Taguchi orthogonal array (OA) L27 (36) with three levels and six input parameters. Experimental estimation and optimization of input parameters for MAF process for stainless steel type 316 plate work piece, six input parameters including amplitude of tooth pole, and number of cycle between teeth, current, cutting speed, working gap, and finishing time, were performed by design of experiment

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sat Dec 31 2022
Journal Name
Al-kindy College Medical Journal
Evaluation of Streptocin SH3, a Bacteriocin produced by Streptococcus sanguinis isolated from Human Dental Plaque
...Show More Authors

Background: Bacteriocin is a peptidic toxin has many advantages to bacteria in their ecological niche and has strong antibacterial activity. Objective: The aim of this study was to evaluation of bacteriocin using Streptococcus sanguinis isolated from human dental caries.

Subjects and Methods: Thirty five streptococcus isolates were diagnosed and tested for their production of bacteriocin, and then the optimal conditions for production of bacteriocin were determined.  After that, the purification of bacteriocin was made partially by ammonium sulfate at 95% saturation levels, followed by and gel filtration chromatography

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Dec 01 2018
Journal Name
Journal Of Economics And Administrative Sciences
The evaluation a proposed strategy for the Ministry of Planning for the years 2018-2022 .
...Show More Authors

abstract

the research discussed a stage of strategic management. The strategic of the evaluation of the proposed strategy through feedback is to ensure that it is implemented with the least possible variation. The research aims at evaluation  a proposed strategy for the Ministry of Planning for the years 2018-2022 in line with the orientations of the state, taking into account the surrounding environmental conditions. It relies on scientific bases and steps to formulate the strategy The extent of the strategy suitability was tested through a set of statistical means and its objectivity was verified through a survey of a number of specialized experts who were selected in accordance with the principle

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Jan 01 2011
Journal Name
Iraqi Journal Of Physics
Calculation of Particle Emission Rates for Nucleon-Induced Reactions with non-Equidistance Spacing Model Dependence
...Show More Authors

Nuclear emission rates for nucleon-induced reactions are theoretically calculated based on the one-component exciton model that uses state density with non-Equidistance Spacing Model (non-ESM). Fair comparison is made from different state density values that assumed various degrees of approximation formulae, beside the zeroth-order formula corresponding to the ESM. Calculations were made for 96Mo nucleus subjected to (N,N) reaction at Emax=50 MeV. The results showed that the non-ESM treatment for the state density will significantly improve the emission rates calculated for various exciton configurations. Three terms might suffice a proper calculation, but the results kept changing even for ten terms. However, five terms is found to give

... Show More
View Publication Preview PDF
Publication Date
Wed May 29 2019
Journal Name
Iraqi Journal Of Physics
Improvement the efficiency of SnO2/n-Si detector by engraving method using a CNC machine
...Show More Authors

Tin oxide was deposited by using vacuum thermal method on silicon wafer engraved by Computer Numerical Controlled (CNC) Machine. The inscription was engraved by diamond-made brine. Deep 0.05 mm in the form of concentric squares. Electrical results in the dark were shown high value of forward current and the high value of the detection factor from 6.42 before engraving to 10.41 after engraving. (I-V) characters in illumination with powers (50, 100, 150, 200, 250) mW/cm2 show Improved properties of the detector, Especially at power (150, 200, 250) mW/cm2. Response improved in rise time from 2.4 μs to 0.72 μs and time of inactivity improved 515.2 μs to 44.2 μs. Sensitivity angle increased at zone from 40o to 65o.

View Publication Preview PDF
Crossref
Publication Date
Sun Jul 12 2020
Journal Name
Medico-legal Update
New Record of the Genus Hydrotaea Robineau-Desvoidy, 1830 (Diptera, Muscidae) from Kerbala City, Iraq
...Show More Authors

View Publication
Crossref
Publication Date
Sun Jun 05 2016
Journal Name
Baghdad Science Journal
Removal Color Study of Toluidine Blue dye from Aqueous Solution by using Photo-Fenton Oxidation
...Show More Authors

The degradation of Toluidine Blue dye in aqueous solution under UV irradiation is investigated by using photo-Fenton oxidation (UV/H2O2/Fe+). The effect of initial dye concentration, initial ferrous ion concentration, pH, initial hydrogen peroxide dosage, and irradiation time are studied. It is found put that the removal rate increases as the initial concentration of H2O2 and ferrous ion increase to optimum value ,where in we get more than 99% removal efficiency of dye at pH = 4 when the [H2O2] = 500mg / L, [Fe + 2 = 150mg / L]. Complete degradation was achieved in the relatively short time of 75 minutes. Faster decolonization is achieved at low pH, with the optimal value at pH 4 .The concentrations of degradation dye are detected by spectr

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Jan 01 2024
Journal Name
Communications In Computer And Information Science
Enhancing the Performance of Wireless Body Area Network Routing Protocols Based on Collaboratively Evaluated Values
...Show More Authors

Wireless Body Area Sensor Network (WBASN) is gaining significant attention due to its applications in smart health offering cost-effective, efficient, ubiquitous, and unobtrusive telemedicine. WBASNs face challenges including interference, Quality of Service, transmit power, and resource constraints. Recognizing these challenges, this paper presents an energy and Quality of Service-aware routing algorithm. The proposed algorithm is based on each node's Collaboratively Evaluated Value (CEV) to select the most suitable cluster head (CH). The Collaborative Value (CV) is derived from three factors, the node's residual energy, the distance vector between nodes and personal device, and the sensor's density in each CH. The CEV algorithm operates i

... Show More
View Publication
Scopus Crossref
Publication Date
Thu Jan 23 2020
Journal Name
Acoustics Australia
Absorption Coefficient of a Double-Layer Inhomogeneous Micro-perforated Panel Backed with Multiple Cavity Depths
...Show More Authors

Double-layer micro-perforated panels (MPPs) have been studied extensively as sound absorption systems to increase the absorption performance of single-layer MPPs. However, existing proposed models indicate that there is still room for improvement regarding the frequency bands of absorption for the double-layer MPP. This study presents a double-layer MPP formed with two single MPPs with inhomogeneous perforation backed by multiple cavities of varying depths. The theoretical formulation is developed using the electrical equivalent circuit method to calculate the absorption coefficient under a normal incident sound. The simulation results show that the proposed model can produce absorption coefficient with wider absorption bandwidth compared w

... Show More
View Publication
Scopus (19)
Crossref (16)
Scopus Clarivate Crossref