Preferred Language
Articles
/
bijps-367
Bioequivalence and Pharmacokinetics Comparison of Two Formulations of Extended-Release Pentoxifylline Tablets in Healthy Subjects after Fasting and Fed Conditions
...Show More Authors

The pharmacokinetics and bioequivalence of a newly developed extended-released (ER) tablet containing 400 mg pentoxifylline as a test product was compared with the reference brand product Trental® 400 mg ER tablet produced by Sanofi-Aventis. Two separate studies were conducted simultaneously. The first study was conducted under fasting condition, whereas, the second study was conducted under fed condition; using the same batches of the test and reference products in both studies. In each study, both products were administered to 32 healthy male adult volunteers applying a single-dose, two-treatment, two-period, two-sequence, randomized crossover design with one-week washout period between dosing. Twenty two blood samples were withdrawn from each volunteer over 24 hours period.  Pentoxifylline concentrations were determined in plasma by a validated HPLC method according to FDA Bioanalytical Method Validation Guidance using UV detection and chloramphenicol as internal standard. The lower limit of quantitation of the drug in plasma was 5 ng/ml and the upper limit of quantitation was 500 ng/ml. From the plasma concentration-time data of each individual, the pharmacokinetic parameters; Cmax,  AUC0-t, AUC0-Â¥, Cmax/AUC0-Â¥, Tmax, lZ & T0.5; were calculated applying non-compartmental analysis. Data of the test and reference products were statistically analyzed to test for bioequivalence of the two products, using criteria of FDA and EMEA Guidance.  The pharmacokinetic parameters mentioned above were statistically analyzed by descriptive statistics, ANOVA test and 90% Confidence Interval (CI). ANOVA test involved the calculation of the effects of: treatment, period, sequence and subjects nested in sequence. According to the above guidance, the primary pharmacokinetic parameters used for bioequivalence testing, namely Cmax, AUC0-t and AUC0-Â¥ were also statistically analyzed by ANOVA & CI tests using the corresponding Ln-transformed values. The mean values  Cmax,  AUC0-t , AUC0-Â¥ , Cmax/AUC0-Â¥ , Tmax, lZ & T0.5 for the test formula obtained from the fasting study  were; 144.4 ng/ml,  845.4 ng.hr/ml, 868.4 ng.hr/ml, 0.186 hr-1, 3.29 hr, 0.561 hr-1 and 1.65 hr, respectively; and the mean values of these parameters for the reference formula were; 150.0 ng/ml,  871.1 ng.hr/ml, 893.7 ng.hr/ml, 0.177 hr-1, 3.70 hr, 0.558 hr-1 and 1.59 hr,  respectively.  The mean values of the above mentioned parameters for the test formula obtained from the fed study were; 157.8 ng/ml, 826.5 ng.hr/ml, 853.8 ng.hr/ml, 0.198 hr-1, 5.4 hr, 0.458 hr-1 and 2.06 hr, respectively; and the mean values of these parameters for the reference formula were; 162.1 ng/ml, 869.7 ng.hr/ml, 894.8 ng.hr/ml, 0.196 hr-1, 4.1 hr, 0.525 hr-1 and 1.80 hr, respectively.  Based on criteria of FDA and   EMEA Guidance on Bioavailability and Bioequivalence, the results of the fasting and fed studies demonstrated bioequivalence of the two products under either condition. Accordingly, it is concluded that the newly developed ER tablet containing 400 mg pentoxifylline is bioequivalent to Trental® 400 mg ER tablet produced by Sanofi-Aventis.

Keywords: Pentoxifylline, Pharmacokinetics, Bioequivalence.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Aug 13 2020
Journal Name
Periodicals Of Engineering And Natural Sciences
A comparison of some forecasting models to forecast the number of old people in Iraqi retirement homes
...Show More Authors

Statistical methods of forecasting have applied with the intention of constructing a model to predict the number of the old aged people in retirement homes in Iraq. They were based on the monthly data of old aged people in Baghdad and the governorates except for the Kurdistan region from 2016 to 2019. Using Box-Jenkins methodology, the stationarity of the series was examined. The appropriate model order was determined, the parameters were estimated, the significance was tested, adequacy of the model was checked, and then the best model of prediction was used. The best model for forecasting according to criteria of (Normalized BIC, MAPE, RMSE) is ARIMA (0, 1, 2).

Scopus
Publication Date
Thu Jun 30 2016
Journal Name
Al-kindy College Medical Journal
Power Versus Conventional Color Doppler Sonographic Diagnosis Of Acute Cholecystitis: Comparison In The Depiction Of Mural Flow
...Show More Authors

Background: Gray-scale sonography is generally
considered as a first-line diagnostic tool for patient with
suspected acute cholecystitis. It is suggested by gallstones,
Murphy's sign, thickening of the gallbladder wall and bile
sludging, but the specificity of these sonographic findings
are not as high as their sensitivity. Blood flow of the
gallbladder wall is increased in acute inflammation.
Objective: To evaluate the sensitivity and specificity of
power Doppler sonography and compared with conventional
color Doppler and gray-scale sonography in diagnosing
patients with acute cholecystitis.
Type of the study: This was a cross sectional study.
Patients and methods: The study was conducted t

... Show More
View Publication Preview PDF
Publication Date
Tue Mar 01 2016
Journal Name
Journal Of Baghdad College Of Dentistry
A Comparison of the Effectiveness of Reciprocating System with Continuous Rotary Systems in Non-Surgical Endodontic Retreatment
...Show More Authors

Background: Optimal root canal retreatment was required safe and efficient removal of filling material from root canal. The aim of this in vitro study was to compare the efficacy of reciprocating and continuous motion of four retreatment systems in removal of root canal filling material. Materials and Methods: Forty distal roots of the mandibular first molars teeth were used in this study, these roots were embedded in cold clear acrylic,roots were instrumented using crown down technique and rotary ProTaper systemize Sx to size F2 ,instrumentation were done with copiousirrigation of 2.5% sodium hypochlorite and 17% buffered solution of EDTA was used as final irrigant followed by distilledwater, roots were obturated with AH26 sealer and Prota

... Show More
Preview PDF
Publication Date
Wed Aug 27 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Evaluation of shear bond strength of zirconia to tooth structure after different zirconia surface treatment techniques
...Show More Authors

Background: This study aimed to evaluate the effect of zirconia different surface treatments (primer, sandblast with 50μmAl2O3, Er,Cr:YSGG laser) on shear bond strength between zirconia surface and resin cement. Material and methods: Sixty presintered Y-TZP zirconia cylinder specimens (IPS e.max ZirCAD, Ivoclar vivadent) will be fabricated and sintered in high temperature furnace of (1500 C for 8 hours) according to manufacturer’s instructions to the selected size and shape of (5mm. in diameter and 6mm in height). All specimens were ground flat using 600.800.1000.1200, aluminum oxide abrasive paper to obtain a standardized surface roughness. Surface roughness values were then recorded in µm using surface roughness tester (profi

... Show More
View Publication Preview PDF
Publication Date
Thu Nov 02 2023
Journal Name
Journal Of Engineering
An Overview of How the Petrophysical Properties of Rock Influenced After Being Exposed to Cryogenic Fluid
...Show More Authors

Exposure to cryogenic liquids can significantly impact the petrophysical properties of rock, affecting its density, porosity, permeability, and elastic properties. These effects can have important implications for various applications, including oil and gas production and carbon sequestration. Cryogenic liquid fracturing is a promising alternative to traditional hydraulic fracturing for exploiting unconventional oil and gas resources and geothermal energy. This technology offers several advantages over traditional hydraulic fracturing, including reduced water consumption, reduced formation damage, and a reduced risk of flow-back fluid contamination. In this study, an updated review of recent studies demonstrates how the

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Fri Jan 10 2020
Journal Name
Polymers
Influence of Polyphosphates on the Physicochemical Properties of Poly (Vinyl Chloride) after Irradiation with Ultraviolet Light
...Show More Authors

Three new polyphosphates were synthesized in good yields by reacting diethylenetriamine with the appropriate phosphate ester in ethanol under acidic conditions. The polyphosphate structures were determined using FT-IR and 1H-NMR spectroscopies, and their elemental compositions were confirmed by EDX spectroscopy. Polyphosphates were added to poly(vinyl chloride) (PVC) at low concentrations to fabricate thin films. The PVC films were irradiated with ultraviolet light for long periods, and the effect of polyphosphates as the photostabilizer was investigated by determining changes in the infrared spectra (intensity of specific functional group peaks), reduction in molecular weight, weight loss, and surface morphology. Minimal changes we

... Show More
View Publication
Scopus (41)
Crossref (35)
Scopus Clarivate Crossref
Publication Date
Thu Mar 30 2023
Journal Name
Journal Of Economics And Administrative Sciences
Comparison of Some Methods for Estimating Nonparametric Binary Logistic Regression
...Show More Authors

In this research, the methods of Kernel estimator (nonparametric density estimator) were relied upon in estimating the two-response logistic regression, where the comparison was used between the method of Nadaraya-Watson and the method of Local Scoring algorithm, and optimal Smoothing parameter λ was estimated by the methods of Cross-validation and generalized Cross-validation, bandwidth optimal λ has a clear effect in the estimation process. It also has a key role in smoothing the curve as it approaches the real curve, and the goal of using the Kernel estimator is to modify the observations so that we can obtain estimators with characteristics close to the properties of real parameters, and based on medical data for patients with chro

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Sep 01 2012
Journal Name
Journal Of Economics And Administrative Sciences
A comparison Of Some Semiparametric Estimators For consumption function Regression
...Show More Authors

    This article aims to explore the importance of estimating the a semiparametric regression function ,where we suggest a new estimator beside the other combined estimators and then we make a comparison among them by using simulation technique . Through the simulation results we find  that the suggest estimator is the best with the first and second models ,wherealse for the third model we find Burman and Chaudhuri (B&C) is best.

View Publication Preview PDF
Crossref
Publication Date
Fri Sep 06 2024
Journal Name
Journal Of Economics And Administrative Sciences
Comparison of Some Wavelet Transformations to Estimate Nonparametric Regression Function
...Show More Authors

The purpose of this article is to improve and minimize noise from the signal by studying wavelet transforms and showing how to use the most effective ones for processing and analysis. As both the Discrete Wavelet Transformation method was used, we will outline some transformation techniques along with the methodology for applying them to remove noise from the signal. Proceeds based on the threshold value and the threshold functions Lifting Transformation, Wavelet Transformation, and Packet Discrete Wavelet Transformation. Using AMSE, A comparison was made between them , and the best was selected. When the aforementioned techniques were applied to actual data that was represented by each of the prices, it became evident that the lift

... Show More
Crossref
Publication Date
Mon Dec 01 2014
Journal Name
Journal Of Economics And Administrative Sciences
Comparison between some of linear classification models with practical application
...Show More Authors

Linear discriminant analysis and logistic regression are the most widely used in multivariate statistical methods for analysis of data with categorical outcome variables .Both of them are appropriate for the development of linear  classification models .linear discriminant analysis has been that the data of explanatory variables must be distributed multivariate normal distribution. While logistic regression no assumptions on the distribution of the explanatory data. Hence ,It is assumed that logistic regression is the more flexible and more robust method in case of violations of these assumptions.

In this paper we have been focus for the comparison between three forms for classification data belongs

... Show More
View Publication Preview PDF
Crossref