Preferred Language
Articles
/
bijps-361
Formulation and Evaluation of Nystatin Microparticles as a Sustained Release System
...Show More Authors

Nystatin is the drug of choice for treatment of cutaneous fungal infections with main disadvantage that is the need for multiple applications to achieve complete eradication which may reduce patient compliance. Microparticles offer a solution for such issue as they are one of sustained release preparations that achieve slow release of drug over an extended period of time. The objectives of this study were to fabricate nystatin-loaded chitosan microparticles with the ultimate goal of prolonging drug release and to analyze the influence of polymer concentration on various properties of microparticles. Microparticles were prepared by chemical cross-linking method using glutaraldehyde as cross-linking agent. Five formulas, namely N1C1, N1C2, N1C3, N1C4 and N1C5, were prepared and the effect of drug to polymer ratio was studied with respect to drug loading, encapsulation efficiency, particle size and morphology. Furthermore the prepared microparticles were subjected to various physico-chemical studies, such as drug- polymer compatibility by Fourier Transform Infrared Spectroscopy (FTIR) and in-vitro drug release characteristics. Microparticles obtained from N1C1, N1C2 and N1C3 formulas were regular in shape with mean particle size ranging between 1µm and 10µm. N1C5 formula was resulted in particles with irregular shape while N1C4 showed a blend of microparticles and deformed particles. The effect of chitosan concentration on drug loading and entrapment efficiency was studied. The results showed increment in these parameters that was directly proportional to the increment in polymer concentration. Percentage yield showed a significant increment which was related to the increment in the ratio of chitosan used during the study. FTIR results showed no interactions between nystatin and chitosan. DSC studies proved the crystalline nature of nystatin and chitosan. On other hand, the thermogram of loaded microparticles showed the absence of endothermic peak corresponding to nystatin which may indicate the loss of the crystalline nature of the drug presented inside the microparticles. In- vitro release studies resulted in 95.6% release of nystatin for N1C1 after 15 hours. N1C1 appeared to be promising in formulating microparticles that provide nearly complete release of the drug within15 hours. This formula can be selected in future work to be formulated as topical gel that prolongs the release of nystatin.

Keywords: Nystatin, Chitosan, Glutaraldehyde, Chemical cross-linking.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Jan 01 2024
Journal Name
Lecture Notes In Networks And Systems
Implementing a Smart Low-Cost System for Diagnosing Bacteria in Women
...Show More Authors

View Publication
Scopus Clarivate Crossref
Publication Date
Tue Jan 01 2008
Journal Name
Journal Of Engineering
USING FUZZY LOGIC CONTROLLER FOR A TWO- TANK LEVEL CONTROL SYSTEM
...Show More Authors

This paper presents a fuzzy logic controller for a two-tank level control system, which is a process with a dead time. The fuzzy controller is a proportional-integral (PI-like) fuzzy controller which is suitable for steady state behavior of the system. Transient behavior of the system was improved without the need for a derivative action by suitable change in the rule base of the controller. Simulation results showed the step response of the two-tank level control system when this controller was used to control this plant and the effect of the dead time on the response of the system.

Publication Date
Tue Aug 01 2023
Journal Name
Journal Of Engineering
Developing a Proposed System to Organize the Investment Opportunities in Iraq
...Show More Authors

......

The Iraqi government seeks to overcome the financial crisis by investing and privatizing some projects to achieve sustainable growth. Most of the investment projects in Iraq suffer from many constraints that greatly impact the success of these projects. A survey of the opinions of a group of experts was conducted to identify the most important constraints facing the investment process in Iraq. Then the experts' answers were arranged in a closed questionnaire and distributed to the research sample for which the statistical analysis was conducted. Through it, the most important (17) factors that had the greatest impact on the failure of investment projects in Iraq were reached. One of the main constraints was

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Jan 01 2006
Journal Name
Journal Of Engineering
SELF ORGANIZING FUZZY CONTROLLER FOR A NON-LINEAR TIME VARYING SYSTEM
...Show More Authors

This paper proposes a self organizing fuzzy controller as an enhancement level of the fuzzy controller. The adjustment mechanism provides explicit adaptation to tune and update the position of the output membership functions of the fuzzy controller. Simulation results show that this controller is capable of controlling a non-linear time varying system so that the performance of the system improves so as to reach the desired state in a less number of samples.

Publication Date
Sun Apr 11 2021
Journal Name
Environment, Development And Sustainability
Developing a system for assessing the sustainability in school building projects
...Show More Authors

View Publication
Crossref (9)
Clarivate Crossref
Publication Date
Wed Aug 01 2012
Journal Name
I-manger's Journal On Information Technology
A MODULE FOR ENHANCING RECOGNITION SYSTEM FOR QR CODE SCANNED IMAGE
...Show More Authors

A QR code is a type of barcode that can hold more information than the familiar kind scanned at checkouts around the world. The “QR” stands for “Quick Response”, a reference to the speed at which the large amounts of information they contain can be decoded by scanners. They are being widely used for advertising campaigns, linking to company websites, contest sign-up pages and online menus. In this paper, we propose an efficient module to extract QR code from background and solve problem of rotation in case of inaccurate image taken from mobile camera.

Publication Date
Wed May 14 2025
Journal Name
Reproductive Biology And Endocrinology
The aryl hydrocarbon receptor: a new frontier in male reproductive system
...Show More Authors

Background: The aryl hydrocarbon receptor (AhR) is a ligand-activated transcription factor historically recognized for its role in the regulation of toxicity mediated by environmental chemicals. Recent research points to AhR's critical participation in male reproductive physiology, particularly in spermatogenesis, hormone signaling, and the maintenance of sperm quality. Both endogenous ligands (e.g., dietary and gut microbiota-derived metabolites) and exogenous pollutants (e.g., dioxins and benzo-α-pyrene) influence AhR-mediated pathways, making it a key link between environmental exposures and male fertility. Results: This review highlights AhR's influence on the male reproductive system, emphasizing the role of endogenous AhR ligands an

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Sun Dec 31 2023
Journal Name
Lark
Digital and pedagogical practices of French as a foreign language in a post-COVID-19 context (The case of the University of Baghdad)
...Show More Authors

View Publication Preview PDF
Publication Date
Thu Jan 12 2023
Journal Name
Journal Of The Saudi Society Of Agricultural Sciences
Effect of planting density, foliar spraying and overlapping system on the growth and productivity using soilless culture system
...Show More Authors

Scopus (5)
Scopus
Publication Date
Wed Mar 10 2021
Journal Name
Baghdad Science Journal
New Method for the On-Line Determination of Molybdenum Via New Microphotometric Home Mode Instrument, Using Hight Emitting Diode as a Variable Intensity Radiant Source with a Miniture Photosilicone Diode Detector for System: Molybdenum(VI)-Hydrogen Peroxide-Ammonium Solution
...Show More Authors

This research work aims to the determination of molybdenum (VI) ion via the formation of peroxy molybdenum compounds which has red-brown colour with absorbance wave length at 455nm for the system of ammonia solution-hydrogen peroxide-molybdenum (VI) using a completely newly developed microphotometer based on the ON-Line measurement. Variation of responses expressed in millivolt. A correlation coefficient of 0.9925 for the range of 2.5-150 ?g.ml-1 with percentage linearity of 98.50%. A detection limit of 0.25 ?g.ml-1 was obtained. All physical and chemical variable were optimized interferences of cation and anion were studied classical method of measurement were done and compared well with newly on-line measurements. Application for the use

... Show More
View Publication Preview PDF
Crossref