Preferred Language
Articles
/
bijps-361
Formulation and Evaluation of Nystatin Microparticles as a Sustained Release System
...Show More Authors

Nystatin is the drug of choice for treatment of cutaneous fungal infections with main disadvantage that is the need for multiple applications to achieve complete eradication which may reduce patient compliance. Microparticles offer a solution for such issue as they are one of sustained release preparations that achieve slow release of drug over an extended period of time. The objectives of this study were to fabricate nystatin-loaded chitosan microparticles with the ultimate goal of prolonging drug release and to analyze the influence of polymer concentration on various properties of microparticles. Microparticles were prepared by chemical cross-linking method using glutaraldehyde as cross-linking agent. Five formulas, namely N1C1, N1C2, N1C3, N1C4 and N1C5, were prepared and the effect of drug to polymer ratio was studied with respect to drug loading, encapsulation efficiency, particle size and morphology. Furthermore the prepared microparticles were subjected to various physico-chemical studies, such as drug- polymer compatibility by Fourier Transform Infrared Spectroscopy (FTIR) and in-vitro drug release characteristics. Microparticles obtained from N1C1, N1C2 and N1C3 formulas were regular in shape with mean particle size ranging between 1µm and 10µm. N1C5 formula was resulted in particles with irregular shape while N1C4 showed a blend of microparticles and deformed particles. The effect of chitosan concentration on drug loading and entrapment efficiency was studied. The results showed increment in these parameters that was directly proportional to the increment in polymer concentration. Percentage yield showed a significant increment which was related to the increment in the ratio of chitosan used during the study. FTIR results showed no interactions between nystatin and chitosan. DSC studies proved the crystalline nature of nystatin and chitosan. On other hand, the thermogram of loaded microparticles showed the absence of endothermic peak corresponding to nystatin which may indicate the loss of the crystalline nature of the drug presented inside the microparticles. In- vitro release studies resulted in 95.6% release of nystatin for N1C1 after 15 hours. N1C1 appeared to be promising in formulating microparticles that provide nearly complete release of the drug within15 hours. This formula can be selected in future work to be formulated as topical gel that prolongs the release of nystatin.

Keywords: Nystatin, Chitosan, Glutaraldehyde, Chemical cross-linking.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Feb 01 2018
Journal Name
Applied Energy
Solidification enhancement of PCM in a triplex-tube thermal energy storage system with nanoparticles and fins
...Show More Authors

View Publication
Scopus (289)
Crossref (271)
Scopus Clarivate Crossref
Publication Date
Wed Jan 02 2019
Journal Name
Differential Equations And Dynamical Systems
Stability and Bifurcation in a Prey–Predator–Scavenger System with Michaelis–Menten Type of Harvesting Function
...Show More Authors

View Publication
Scopus (25)
Crossref (13)
Scopus Clarivate Crossref
Publication Date
Sat Aug 01 2015
Journal Name
Journal Of Engineering
Determination of the Optimum Conditions in Evaluation of Kiwi Juice as Green Corrosion Inhibitor of Steel in Hydrochloric Acid
...Show More Authors

The corrosion protection of low carbon steel in 2.5 M HCl solution by kiwi juice was studied at different temperatures and immersion times by weight loss technique. To study the determination of the optimum conditions from statistical design in evaluation of a corrosion inhibitor, three variables, were considered as the most dominant variables. These variables are: temperature, inhibitor concentration (extracted kiwi juice) and immersion time at static conditions.

These three variables are manipulated through the experimental work using central composite rotatable Box – Wilson Experimental Design (BWED) where second order polynomial model was proposed to correlate the studied variables with the corrosion rate o

... Show More
View Publication Preview PDF
Publication Date
Mon Jan 01 2024
Journal Name
Cytokine
Evaluation of IL-8, nitric oxide and macrophage inhibitory factor as clinical circulatory markers in patients with cutaneous leishmaniasis, before and during sodium stibogluconate treatment
...Show More Authors

The clinical spectrum of cutaneous leishmaniasis (CL), an intracellular parasitic pathogen, ranges from a single sore healing to chronic crusty lesions with a manifestation of treatment resistance. The complicated interaction between Leishmania bodies and the early immune response, including innate and adaptive mechanisms, determines the evolution of nodules. This study examined the levels of the chemoattractant interleukin 8 (IL-8), pro-inflammatory nitric oxide (NO), and immunoregulatory macrophage inhibitory factor (MIF) in the serum of subjects recently diagnosed with cutaneous leishmaniasis, in parallel with patients being monitored during consecutive sodium stibogluconate (Pentostam) treatment. A total of 161 serum samples of newly di

... Show More
View Publication
Scopus (6)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Thu Oct 01 2009
Journal Name
Iraqi Journal Of Physics
PMMA/ Anthracene Film as a Low Doses Dosimeter
...Show More Authors

A prepared PMMA/Anthracene film of thickness 70μm was irradiated under reduced pressure ~10-3 to 60Coγ-ray dose of (0.1mrad-10krad) range. The optical properties of the irradiated films were evaluated spectrophotometrically. The absorption spectrum showed induced absorption changes in the 200-400nm range. At 359nm, where there is a decrease in radiation-induced absorption, the optical density as a function of absorbed dose is linear from 10mrad-10Krad.It can therefore, be used as radiation dosimeter for gamma ray in the range 10mrd-10krad

View Publication Preview PDF
Publication Date
Fri Apr 30 2021
Journal Name
Eastern-european Journal Of Enterprise Technologies
Implementation of artificial neural network to achieve speed control and power saving of a belt conveyor system
...Show More Authors

According to the importance of the conveyor systems in various industrial and service lines, it is very desirable to make these systems as efficient as possible in their work. In this paper, the speed of a conveyor belt (which is in our study a part of an integrated training robotic system) is controlled using one of the artificial intelligence methods, which is the Artificial Neural Network (ANN). A visions sensor will be responsible for gathering information about the status of the conveyor belt and parts over it, where, according to this information, an intelligent decision about the belt speed will be taken by the ANN controller. ANN will control the alteration in speed in a way that gives the optimized energy efficiency through

... Show More
View Publication
Scopus (18)
Crossref (8)
Scopus Crossref
Publication Date
Sat Jan 01 2022
Journal Name
Proceeding Of The 1st International Conference On Advanced Research In Pure And Applied Science (icarpas2021): Third Annual Conference Of Al-muthanna University/college Of Science
Iraqi Hawizeh Marsh: A half-century of water surface evaluation
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Tue Mar 01 2016
Journal Name
Journal Of Natural Sciences Research
Spectrophotometric-Assisted Chemometric Method for the Simultaneous Analysis of Furosemide, Carbamazepine, Diazepam, and Carvedilol in Their Bulk and Marketed Formulation
...Show More Authors

Simultaneous determination of Furosemide, Carbamazepine, Diazepam, and Carvedilol in bulk and pharmaceutical formulation using the partial least squares regression (PLS-1 and PLS-2) is described in this study. The two methods were successfully applied to estimate the four drugs in their quaternary mixture using UV spectral data of 84synthetic mixtures in the range of 200-350nm with the intervals Δλ=0.5nm. The linear concentration range were 1-20 μg.mL-1 for all, with correlation coefficient (R2) and root mean squares error for the calibration (RMSE) for FURO, CARB, DIAZ, and CARV were 0.9996, 0.9998, 0.9997, 0.9997, and 0.1128, 0.1292, 0.1868,0.1562 respectively for PLS-1, and for PLS-2 were 0.9995, 0.9999, 0.9997, 0.9998, and 0.1127, 0.

... Show More
Publication Date
Mon Jun 19 2017
Journal Name
Arabian Journal For Science And Engineering
A New Method to Tune a Fractional-Order PID Controller for a Twin Rotor Aerodynamic System
...Show More Authors

View Publication
Scopus (33)
Crossref (29)
Scopus Clarivate Crossref
Publication Date
Fri Jan 01 2016
Journal Name
Animal Nutrition And Feed Technology
Insect Meal as a Source of Protein in Animal Diet
...Show More Authors

View Publication
Scopus (19)
Crossref (13)
Scopus Clarivate Crossref