The discovery of novel therapeutic molecules is always difficult, and there are a variety of methodologies that use the most diverse and innovative medicinal chemistry approaches. One such approach is the deuteration technique: Deuteration is the process of substituting deuterium for hydrogen in a molecule. When compared to the drug molecule, its deuterated analogues may retain the features of the original molecule and, in some cases, improve its pharmacological activity, with fewer side effects and lower toxicity. Metronidazole is a commonly used antibiotic to treat anaerobic bacterial infections, protozoal and microaerophilic bacterial infections. Metronidazole has a half-life of 6.5 ± 2.9 hours. A number of studies have recently been conducted on the selective substitution of hydrogen with deuterium. which increases the bond strength, increasing the biological half-life and, consequently, the drug's metabolic stability also increases. In an attempt to address metronidazole's drawbacks and clinical resistance, deuterated metronidazole was synthesised, characterised, and tested for antibacterial, antifungal, and anti-tubercular activities. The metronidazole and its deuterated compound showed equipotent antifungal activity and aerobic antibacterial activity. Also, when compared with the non-deuterated compound, deuterated metronidazole exhibited better anaerobic antibacterial and anti-tubercular activity.
In Incremental sheet metal forming process, one important step is to produce tool path, an
accurate tool path is one of the main challenge of incremental sheet metal forming
process. Various factors should be considered prior to generation of the tool path i.e.
mechanical properties of sheet metal, the holding mechanism, tool speed, feed rate and
tool size. In this work investigation studies have been carried out to find the different tool
path strategies to control the twist effect in the final product manufactured by single point
incremental sheet metal forming (SPIF), an adaptive tool path strategy was proposed and
examined for several Aluminum conical models. The comparison of the proposed tool path with t
The temperature control process of electric heating furnace (EHF) systems is a quite difficult and changeable task owing to non-linearity, time delay, time-varying parameters, and the harsh environment of the furnace. In this paper, a robust temperature control scheme for an EHF system is developed using an adaptive active disturbance rejection control (AADRC) technique with a continuous sliding-mode based component. First, a comprehensive dynamic model is established by using convection laws, in which the EHF systems can be characterized as an uncertain second order system. Second, an adaptive extended state observer (AESO) is utilized to estimate the states of the EHF system and total disturbances, in which the observer gains are updated
... Show MoreIn this study, the photodegradation of Congo red dye (CR) in aqueous solution was investigated using Au-Pd/TiO2 as photocatalyst. The concentration of dye, dosage of photocatalyst, amount of H2O2, pH of the medium and temperature were examined to find the optimum values of these parameters. It has been found that 28 ppm was the best dye concentration. The optimum amount of photocatalyst was 0.09 g/75 mL of dye solution when the degradation percent was ~ 96 % after irradiation time of 12 hours, while the best amount of hydrogen peroxide was 7μl/75 mL of dye solution at degradation percent ~97 % after irradiation time of 10 hours, whereas pH 5 was the best value to carry out the reaction at the highest degradation percent. In additio
... Show MoreIn this study, the photodegradation of Congo red dye (CR) in aqueous solution was investigated using Au-Pd/TiO2 as photocatalyst. The concentration of dye, dosage of photocatalyst, amount of H2O2, pH of the medium and temperature were examined to find the optimum values of these parameters. It has been found that 28 ppm was the best dye concentration. The optimum amount of photocatalyst was 0.09 g/75 mL of dye solution when the degradation percent was ~ 96 % after irradiation time of 12 hours, while the best amount of hydrogen peroxide was 7μl/75 mL of dye solution at degradation percent ~97 % after irradiation time of 10 hours, whereas pH 5 was the best value to carry out the reaction at the highest deg
... Show More