Preferred Language
Articles
/
bijps-1699
Colorimetric Determination of Salbutamol Sulfate using Spectrophotometry-Continuous Flow Injection Technique in Pure and Pharmaceutical Forms
...Show More Authors

Simple, precise and economic batch and flow injection analysis (FIA)-spectrophotometric methods have been established for simultaneous determination of salbutamol sulfate (SLB) in bulk powder and pharmaceutical forms. Both methods based on diazotization coupling reaction of SLB with another drug compound (sulfadimidine) as a safe and green diazotization agent in alkaline medium. At 444 nm, the maximum absorption of the orange azo-dye product was observed. A thorough investigation of all chemical and physical factors was conducted for batch and FIA procedures to achieve high sensitivity. Under the optimized experimental variables, SLB obeys Beer’s law in the concentration range of 0.25-4 and 10-100 μg/mL with limits of detection of 0.09 and 2.51 μg/mL for batch and FIA procedures respectively. The low percentage relative standard deviation of less than 1% (n=5) for both methods confirmed the applicability of these methods. Using F and t tests, a statistical comparison of the recommended approaches with the standard spectrophotometric method revealed no significant differences in accuracy or precision.

 

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Nov 01 2021
Journal Name
Journal Of Physics: Conference Series
Light scattering detector based on light-emitting diodes-Solar cells for a flow analysis of Warfarin in pure form and pharmaceutical formulations
...Show More Authors
Abstract<p>Continuous turbidimetric analysis (CTA) for a distinctive analytical application by employing a homemade analyser (NAG Dual & Solo 0-180°) which contained two consecutive detection zones (measuring cells 1 & 2) is described. The analyser works based on light-emitting diodes as a light source and a set of solar cells as a light detector for turbidity measurements without needing further fibres or lenses. Formation of a turbid precipitated product with yellow colour due to the reaction between the warfarin and the precipitation reagent (Potassium dichromate) is what the developed method is based on. The CTA method was applied to determine the warfarin in pure form and pharmaceu</p> ... Show More
Scopus (14)
Crossref (5)
Scopus Crossref
Publication Date
Fri Jul 11 2025
Journal Name
Scientific Reports
Molecular docking study and pharmacokinetic insights of rifampicin in pure and capsule dosage forms
...Show More Authors

To detect the amount of rifampicin in bulk and medicinal dosage formulations, an accurate and costeffective UV spectrophotometric technique has been developed using the area under the peak to estimate the presence of rifampicin. This range of wavelengths (300–356 nm) was chosen. The method showed linearity in the 2–22 μg/mL range, with R2 being2 0.9996. The developed method’s linearity, detection limit, quantification limit, precision, repeatability, and accuracy were all statistically and experimentally validated. The suggested methodology can be used for routine quality control analysis of rifampicin in pure form and in capsule dosage form, as demonstrated by the satisfactory recovery percentage results. This study explores the str

... Show More
View Publication
Scopus (1)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Mon Feb 15 2021
Journal Name
Systematic Review In Pharmacy
Colorimetric Determination Of Sitagliptin As An Oxidation Derivative Of Ninhydrin
...Show More Authors

A sensitive and accurate colorimetric method was developed for the determination of the Sitagliptin phosphate monohydrate, here and after will be named Sitagliptin, in its pure and pharmaceutical form. The suggested approach is based on boosting the sensitivity of the traditional spectrometric methods by derivatizing Sitagliptin into a colored product that absorbs the visible spectrum at 573 nm. The proposed method has effectively improved the sensitivity and the limit of detection for the analysis of Sitagliptin. A linear calibration curve was obtained over the concentration range of 0.1-10 μg/ml with a correlation coefficient of 0.9983. The calculated recovery was within the range of 98.98–100.11%. While the limit of detection LOD and

... Show More
Preview PDF
Publication Date
Sun Mar 06 2011
Journal Name
Baghdad Science Journal
Spectrophotometric Determination of Epinephrine in Pharmaceutical Preparations Using Praseodymium as Mediating Metals
...Show More Authors

A simple, accurate and sensitive spectrophotometric method for the determinaion of epinephrine is described . The method is based on the coordination of Pr (III) with epinephrine at pH 6. Absorbance of the resulting orange yellow complex is measured at 482 nm . A graph of absorbance versus concentrations shows that beer 's low is obeyed over the concentration range (1-50)mg.ml-1 of epinephrine with molar absorpitivity of ( 2.180x103 L.mol-1.cm-1 ), a sandell sensitivity of (0.084 mg.cm-2 ), a relative error of (-2.83%) , a corrolation coffecient (r= 0.9989) and recovery % ( 97.03 ± 0.75 ) depending on the concentration.This method is applied to analyse EP in several commercially available pharmaceutical preparations

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Fri Jan 01 2021
Journal Name
Microchemical Journal
A flow analysis system integrating an optoelectronic detector for the quantitative determination of active ingredients in pharmaceutical formulations
...Show More Authors

Scopus (24)
Crossref (17)
Scopus Clarivate Crossref
Publication Date
Mon Aug 05 2024
Journal Name
Pharmacia
A validated spectrophotometric analysis for simultaneous estimation of vincristine sulfate and bovine serum albumin in pure preparations using Vierordt’s method
...Show More Authors

The novel Vierordt’s approach, or simultaneous equation method, was created and validated for the concurrent determination of vincristine sulfate (VCS) and bovine serum albumin (BSA) in pure solutions utilizing UV spectrophotometry. It is simple, precise, economical, rapid, reliable, and accurate. This method depends on measuring absorbance at two wavelengths, 296 nm and 278 nm, which correspond to the λmax of VCS and BSA in deionized water, respectively. The calibration curves of VCS and BSA are linear at concentration ranges of 10–60 μg/mL and 200–1600 μg/mL, with correlation coefficient values (R2) of 1 and 0.999, respectively. The limits of detection (LOD) and quantification (LO

... Show More
View Publication
Scopus (1)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Sun Nov 01 2015
Journal Name
Karbala International Journal Of Modern Science
Batch and flow injection spectrophotometric methods for the determination of barbituric acid in aqueous samples via oxidative coupling with 4-aminoantipyrine
...Show More Authors

A batch and flow injection (FI) spectrophotometric methods are described for the determination of barbituric acid in aqueous and urine samples. The method is based on the oxidative coupling reaction of barbituric acid with 4-aminoantipyrine and potassium iodate to form purple water soluble stable product at λ 510 nm. Good linearity for both methods was obtained ranging from 2 to 60 μg mL−1, 5–100 μg mL−1 for batch and FI techniques, respectively. The limit of detection (signal/noise = 3) of 0.45 μg mL−1 for batch method and 0.48 μg mL−1 for FI analysis was obtained. The proposed methods were applied successfully for the determination of barbituric acid in tap water, river water, and urine samples with good recoveries of 99.92

... Show More
View Publication
Scopus (13)
Crossref (5)
Scopus Crossref
Publication Date
Sat Jun 21 2025
Journal Name
Journal Of University Of Anbar For Pure Science
Semi – automated analysis for the Nanoscale determination of Chlorpheniramine maleate drug using sodium nitroprusside by continuous flow feed via homemade NAG-SSP Photometer
...Show More Authors

This study presents a rapid, sensitive, and straightforward approach to measure chlorpheniramine maleate (CPM) by using turbidity CFIA. The method involves CPM reacting with sodium nitroprusside (Nitropress) to produce a pale white precipitate. The NAG-SSP-5S1D analyzer was used to measure turbidity at 0°–180° angle to detect the attenuation of incident light as a result of collision on the surfaces of the precipitate particles. The linear range of CPM measurements was between 0.008 and 11 m.mol/L, with correlation coefficient of 0.9983 and R2% = 99.65. The limit of detection was determined to be 0.0328 µg/sample from the lowest concentration in the calibration curve, and the repeatability of the method (RSD%) was less than 0.4% (n = 6

... Show More
View Publication
Scopus (1)
Scopus Crossref
Publication Date
Mon Sep 15 2014
Journal Name
Ibn Al-haitham Jour. For Pure & Appl. Sci.
Simultaneous Determination of Ciprofloxacin Hydrochloride and Mebeverin Hydrochloride by Derivative Spectrophotometry
...Show More Authors

A new Spectrophotometric method, is for individual and simultaneous determination of Ciprofloxacin hydrochloride(CIP) and Mebeverin hydrochloride(MEB) by the first and second derivative mode techniques. The first and second derivative spectra of these compounds permitted individual and simultaneous determination of CIP and MEB in concentration range of (4-28μg/mL) by measuring the amplitude of peak- to- base line and the area under peak at selected spectrum intervals. The methods showed a reasonable precision and accuracy and have been applied to determine CIP and MEB in four different pharmaceutical preparations.

Preview PDF
Publication Date
Sun Jun 07 2015
Journal Name
Baghdad Science Journal
Spectrophotometric Determination of Paracetamol in bulk and Pharmaceutical Preparations
...Show More Authors

A simple, and rapid spectrophotometric method for the estimation of paracetamol has been developed. The methods is based on diazotisation of 2,4-dichloroaniline followed by a coupling reaction with paracetamol in sodium hydroxide medium. All variables affecting the reaction conditions were carefully studied. Beer's law is obeyed in the concentration range of 4-350 ?gml?1 at 490 nm .The method is successfully employed for the determination of paracetamol in pharmaceutical preparations. No interferes observed in the proposed method. Analytical parameters such as accuracy and precision have been established for the method and evaluated statistically to assess the application of the method.

View Publication Preview PDF
Crossref (2)
Crossref