Osteoporosis (OP)is one of the most important metabolic disorder also affected by interaction of genetic and environmental factors by almost 70% and 30% respectively. Genetic components are identified to strongly effect bone mineral density, bone building and turnover, so they play an important role in determining risk of OP and fragility fractures. This study consists of patient and control group; Group A: (70) postmenopausal women with OP and osteopenia, Group B: (20) control group. five milliliters of blood sample were divided into three tubes; one tube (1ml) contain gel for obtain serum to measure glucose level, the others tubes containing ethylene-diamine-tetra-acetic acid (EDTA), in 2 tube 2ml stored in deep freeze at (–40 Co) until genomic analysis of DNA for the performance of PCR genotyping of gene polymorphisms of RAGE, in 3 tube 2ml used to perform Glycated Hemoglobin % (HbA1c) assays. HbA1c and Serum glucose levels is significantly increased in Group A. a high prevalence of RAGE polymorphism rs1800625 and rs1800624 were detected in postmenopausal women with OP with type2DM. Homozygous 1800625 were (31%) and heterozygous 1800625(31%) compared to control homozygous 1800625 were (5%) and heterozygous 1800625 were (5%) respectively. Homozygous 1800624 were (28.5%) and heterozygous 1800624(28.5%) compared to control homozygous 1800624 were (5%) and heterozygous 1800624 were (20%) respectively. In conclusion, the rs1800625 and rs1800624 polymorphism might be a causal risk allele for OP in post menopause Iraqi women with type2 DM.
The research studied and analyzed the hybrid parallel-series systems of asymmetrical components by applying different experiments of simulations used to estimate the reliability function of those systems through the use of the maximum likelihood method as well as the Bayes standard method via both symmetrical and asymmetrical loss functions following Rayleigh distribution and Informative Prior distribution. The simulation experiments included different sizes of samples and default parameters which were then compared with one another depending on Square Error averages. Following that was the application of Bayes standard method by the Entropy Loss function that proved successful throughout the experimental side in finding the reliability fun
... Show MoreA new Turbidimetric method characterized by simplicity, accuracy and speed for determination of Hydronium ion by continuous flow injection analysis. The method was based on the formation of complex Zn3[Fe(CN)6] for Zinc(II) that was eluted by Hydronium ion from cation exchanger column with Potassium hexacyanoferrate(III) for the formation of a pale yellow precipitate and this precipitate was determined using homemade Linear Array Ayah-5SX1-T-1D continuous flow injection analyser. The optimum parameters were 2.7 mL.min-1 flow rate using H2O as a carrier stream, 1.7 mL.min-1 reagent stream, 110 L sample volume and open valve for the purge of the sample segment. Data treatment shows that linear range 0.01-0.1 mol.L-1 for each acids (HClO
... Show MoreThis study reports on natural convection heat transfer in a square enclosure of length (L=20 cm) with a saturated porous medium (solid glass beads) having same fluid (air) at lower horizontal layer and free air fill in the rest of the cavity's space. The experimental work has been performed under the effects of heating from bottom by constant heat flux q=150,300,450,600 W/m2 for four porous layers thickness Hp (2.5,5,7.5,1) cm and three heaters length δ(20,14,7) cm. The top enclosure wall was good insulated and the two side walls were symmetrically cooled at constant temperature. Four layers of porous media with small porosity, Rayleigh number range (60.354 - 241.41) and (Da) 3.025x10-8 has been investigated. The obtained data of temperatu
... Show MoreThe largest use of x-ray in medical by dentists, employers or persons that needed by patients with specific conditions, lead to higher exposure of x-ray that may cause many diseases. In the present work radiography films have been used in evaluating the efficiency of using unsaturated polyester polymer reinforced with lead oxide (PbO) as shield material for medical x-ray devices, many parameters studied like concentration and thickness that they are increasing the attenuation of x-ray in them. The results show that the attenuation of X-ray increasing with concentration of reinforced material and with thickness, and the optical density decreases with increasing concentration from 0% to 50%, we chose 30% as suitable concentration to increase
... Show MoreAsthma is one of the most common chronic, non-communicable diseases affecting children worldwide. The estimated prevalence of pediatric asthma in Iraq is 15.8%. Physiologic, inflammatory and structural factors contribute to the development of asthma. Assessment and monitoring of asthma control can be done by a validated children asthma control test (CACT). Management of asthma must address three components which are an appropriate management plan, the most appropriate medication if necessary, and the use of safe and effective medication. The management plan should consider patient counseling and education about the definition of asthma, signs, and symptoms, the pathophysiology of asthma, common triggers for asthma and how can avoid them,
... Show MoreThe Khabour reservoir, Ordovician, Lower Paleozoic, Akkas gas field which is considered one of the main sandstone reservoirs in the west of Iraq. Researchers face difficulties in recognizing sandstone reservoirs since they are virtually always tight and heterogeneous. This paper is associated with the geological modeling of a gas-bearing reservoir that containing condensate appears while production when bottom hole pressure declines below the dew point. By defining the lithology and evaluating the petrophysical parameters of this complicated reservoir, a geological model for the reservoir is being built by using CMG BUILDER software (GEM tool) to create a static model. The petrophysical properties of a reservoir were computed using
... Show MoreThis paper compare the accurecy of HF propagation prediction programs for HF circuits links between Iraq and different points world wide during August 2018 when solar cycle 24 (start 2009 end 2020) is at minimun activity and also find out the best communication mode used. The prediction programs like Voice of America Coverage Analysis Program (VOACAP) and ITU Recommendation RS 533 (REC533 ) had been used to generat HF circuit link parameters like Maximum Usable Frequency ( MUF) and Frequency of Transsmision (FOT) .Depending on the predicted parameters (data) , real radio contacts had been done using a radio transceiver from Icom model IC 7100 with 100W RF
... Show More