Preferred Language
Articles
/
bijps-1632
Possible protective effects of two different doses of cyanocobalamin against methotrexate nephrotoxicity in rats
...Show More Authors

Abstract

   Nephrotoxicity is defined as rapid deterioration in kidney functions. It arises from direct exposure to drugs or their metabolites. Methotrexate is a famous chemotherapeutic drug with anti-inflammatory and immunosuppressive properties. A high-dose methotrexate-induced renal dysfunction can be life threatening. Cyanocobalamin, one of the forms of vitamin B12, acts as a coenzyme in the conversion of homocysteine to methionine in the cytosol, and the conversion of methylmalonyl-CoA to succinyl-CoA in the mitochondrion. This study is designed to examine the effect of cyanocobalamin in two different doses each co-administered with methotrexate at 20 mg/kg induced nephrotoxicity in rats through the involvement of Nrf2/keap1 molecular mechanism in this respect. Rats utilized in this study were randomized into 4 groups (ten rats per each group); Group 1- (Control) rats intraperitoneally injected with 0.5ml normal saline once daily for 7 consecutive days. Group 2- Rats intraperitoneally injected with 0.5ml normal saline once daily for 7 consecutive days; and at day 2, a single intraperitoneal dose of methotrexate (20mg/kg) is to be injected. Group 3- Rats intraperitoneally injected with a 0.5mg/kg cyanocobalamin once daily for 7 consecutive days, and at day 2, a single intraperitoneal dose of methotrexate (20mg/kg). Group 4- Rats intraperitoneally injected with a 2mg/kg cyanocobalamin once daily for 7 consecutive days, and at day 2, a single intraperitoneal dose of methotrexate (20mg/kg). Co-administration of cyanocobalamin at doses cyanocobalamin 0.5mg/kg and 2mg/kg with methotrexate showed significant  reduction  (P<0.05) in malondialdehyde, significant elevation (P<0.05)  in reduced glutathione level, significant upregulation in  renal Nrf2 expression and significant down regulation in renal keap1 expression each compared to corresponding levels in methotrexate-only treated group. In conclusion this study demonstrated that co-administration of cyanocobalamin at two different doses with MTX resulted in attenuation of its nephrotoxicity by the utilization of selected parameters.

Keywords: Nephrotoxicity, methotrexate, cyanocobalamin, malondialdehyde, glutathione, Nrf2, Keap1.

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Dec 01 2020
Journal Name
Malaysian Journal Of Biochemistry & Molecular Biology
ANTIBACTERIAL AND ANTIBIOFILM EFFECTS OF BISMUTH NANOPARTICLES PRODUCED BY BACILLUS SUBTILIS AGAINST MULTIDRUG-RESISTANT Pseudomonas aeruginosa
...Show More Authors

This study aimed to determine the effect of green bismuth oxide (BiO) NPs against multidrug-resistant (MDR) Pseudomonas aeruginosa (P. aeruginosa) from wound infections. Among 450 wound samples collected from patients admitted to the hospital, 200 P. aeruginosa isolates were identified. MDR strains of P. aeruginosa were detected by disc diffusion method. BiO NPs were synthesized using wild Bacillus subtilis (B. subtilis) strain and infrared spectroscopy, X-ray diffraction and scanning electron microscopy techniques. The antibacterial effect of the NPs compared to antibiotics against MDR strains was evaluated using a standard disk diffusion method. BiO NPs were synthesized at 0.005 M concentration of solution. According to the SEM im

... Show More
Preview PDF
Scopus (4)
Scopus
Publication Date
Tue Dec 01 2009
Journal Name
Iraqi Journal Of Physics
Spectrophotometrically Analysis of PMMA as a low – Doses Dosimeter
...Show More Authors

Polymethylmethacrylate film (PMMA) of thickness 75 μm was evaluated Spectrophotometrically for using it as a low-doses gamma radiation dosimeter. The doses were examined in the range 0.1 mrad-10 krad. Within an absorption band of 200-400 nm, the irradiated films showed an increase in the absorption intensity with increasing the absorbed doses. Calibration curves for the changes in the absorption differences were obtained at 218, 301, and 343 nm. At 218 nm the response for the absorbed doses is a linear in the range 10 mrad- 10 krad. Hence it is recommended to be adopted as an environmental low doses dosimeter

View Publication Preview PDF
Publication Date
Sun May 07 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Development Of Two Different Spectrophotometric Methods For The Determination Of Atropine Drug In Pure Form And Pharmaceutical Preparations
...Show More Authors

Two methods have been applied for the spectrophotometric determination of atropine, in
bulk sample and in dosage form. The methods are accurate, simple, rapid, inexpensive and
sensitive. The first method depending on the extraction of the formed ion-pair complex with
bromphenol blue (BPB) as a chromogenic reagent in chloroform, use phthalate buffer of pH
3.0; which showed absorbance maxima at 413 nm against reagent blank. The calibration
graph is linear in the ranges of 0.5-40 µg.mL
-1
with detection limit of 0.363µg.mL
-1
. The
second method depending on the measure of the absorbance maxima of the formed charge-transfer complex with 2,3-dichloro-5,6-dicyano-p-benzoquinone (DDQ) at 457 nm against

... Show More
View Publication Preview PDF
Publication Date
Fri Dec 15 2023
Journal Name
Iraqi Journal Of Laser
The Reliability of Two Different Laser Wavelengths in Inducing Bone Healing Around Dental Implants: Comparative Clinical Trial
...Show More Authors

Background/purpose: Dental implantology involves different treatments that have been used in conjunction with dental implant surgery to increase implant stability and bone regeneration process. Photobiomodulation( PBM) can be one of these techniques. The objective of this study was to evaluate the bone density around implants. Materials and methods: in this study, 10 individuals had 20 implants inserted in the posterior of their mandibles. each patient received two implants the left side served as the control whereas the right side served as the study group with a diode laser (same patients). measurements were made for each implant. Measurements were obtained using cone-

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Jan 01 2023
Journal Name
Journal Of Population Therapeutics And Clinical Pharmacology
Evaluation of the Expression of RCC and KIM-1 Biomarkers in Nephrotoxicity of Rabbits Treated with Ochratoxins A
...Show More Authors

View Publication
Clarivate Crossref
Publication Date
Wed Jun 30 2021
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
ELECTROCHEMICAL PREPARATION OF A MOLECULAR IMPRINTED POLYMER ELECTRODE FOR ESTEMATION OF ASPIRIN USING TWO DIFFERENT FUNCTIONAL MONOMERS.: ELECTROCHEMICAL PREPARATION OF A MOLECULAR IMPRINTED POLYMER ELECTRODE FOR ESTEMATION OF ASPIRIN USING TWO DIFFERENT FUNCTIONAL MONOMERS.
...Show More Authors

For aspirin estimated, a molecularly imprinted polymer MIP-ASP electrodes were generated by electro-polymerization process, the electrodes were prepared by combining the template (aspirin) with (vinyl acetate (VA), 1-vinylimidizole (VIZ) as a functional monomer and N, N-methylene bisacrylamide (MBAA) as crosslinkers using benzoyl peroxide (BPO) as an initiator. The efficiency of the membrane electrodes was analyzed by differential pulse voltammetry (DPV). Four electrodes were synthesized using two different plasticizers, di-butyl sebacate (DBS), di-octyl phthalate (DOP) in PVC matrix. Scanning electron microscopy (SEM) was used to describe the generated MIP, studying the electrodes properties, the slope, detection limit, and life

... Show More
View Publication Preview PDF
Publication Date
Sun Jun 30 2013
Journal Name
Al-khwarizmi Engineering Journal
Effects of Different Types of Fillers on Dry Wear Characteristics of Carbon-Epoxy Composite
...Show More Authors

Experimental investigations had been done in this research to demonstrate the effect of carbon fiber and Ceramic fillers contents on the tribological behaviour of (15% volume fraction) carbon-epoxy composite system under varying volume fraction, load, time and sliding distance. The wear resistance were investigated according to ASTM G99-05standard using pin on disc machine to present the composite tribological behaviour. The influence of three ceramic fillers, granite, perlite and calcium carbonate (CaCO3), on the wear of the carbon fabric reinforced epoxy composites under dry sliding conditions has been investigated. The effect of variants in volume fraction, applied load, time and sliding distance on the wear behaviour of po

... Show More
View Publication Preview PDF
Publication Date
Sat Apr 02 2022
Journal Name
The International Conference On Science In Engineering And Technology (icosiet) 2020 (virtually)
The Possible Application of Intelligent Systems in Traditional Courtyard House.
...Show More Authors

View Publication
Publication Date
Thu Jan 12 1995
Journal Name
مجلة العلوم الزراعية العراقية 26 (1), 88-92
The Possible Use Of Pollen Radiation in Date Palm Breeding‏
...Show More Authors

Publication Date
Fri Sep 15 2023
Journal Name
Journal Of Baghdad College Of Dentistry
FEM: Mono-implant cement retained crown with two different adhesive materials
...Show More Authors

Background: The finite element method (FEM) is expected to be one of the most effective computational tools for measuring the stress on implant-supported restorations. This study was designed using the 3D-FEM to evaluate the effect of two adhesive luting types of cement on the occlusal stress and deformation of a hybrid crown cemented to a mono-implant. Materials and Method: The mono-screw STL file was imported into the CAD/CAM system library from a database supported by De-Tech Implant Technology. This was to assist in the accurate reproduction of details and design of a simulated implant abutment. Virtually, a digital crown was designed to be cemented on an abutment screw. A minimum occlusal thickness of 1mm and marginal fitting of 1.2

... Show More
View Publication Preview PDF
Scopus (1)
Crossref (1)
Scopus Crossref