A simple and highly sensitive cloud point extraction process was suggested for preconcentration of micrograms amount of isoxsuprine hydrochloride (ISX) in pure and pharmaceutical samples. After diazotization coupling of ISX with diazotized sulfadimidine in alkaline medium, the azo-dye product quantitatively extracted into the Triton X-114 rich phase, dissolved in ethanol and determined spectrophotometrically at 490 nm. The suggested reaction was studied with and without extraction and simple comparison between the batch and CPE methods was achieved. Analytical variables including concentrations of reagent, Triton X-114 and base, incubated temperature, and time were carefully studied. Under the selected optimum conditions, the linearity ranges of calibration curves were 1-9 and 0.5-8 µg/mL with detection limits of 0.26 and 0.09 µg/mL of ISX for batch and CPE methods respectively. A relative standard deviation (RSD %) best than 1.98 and 2.67 % with the percentage recoveries range 100.14 and 99.63 % were obtained for both methods respectively. The proposed methods were successfully used in routine analysis of ISX in pharmaceutical forms with high accuracy and reproducibility.
The Estimation Of The Reliability Function Depends On The Accuracy Of The Data Used To Estimate The Parameters Of The Probability distribution, and Because Some Data Suffer from a Skew in their Data to Estimate the Parameters and Calculate the Reliability Function in light of the Presence of Some Skew in the Data, there must be a Distribution that has flexibility in dealing with that Data. As in the data of Diyala Company for Electrical Industries, as it was observed that there was a positive twisting in the data collected from the Power and Machinery Department, which required distribution that deals with those data and searches for methods that accommodate this problem and lead to accurate estimates of the reliability function,
... Show MoreBackground: The surgical extraction of impacted third molar usually results in postoperative inflammation manifested as pain, facial swelling and trismus which may cause deterioration in the patient’s quality of life. Methods: This randomized controlled study included 56 patients indicated for surgical extraction of IMTM under local anesthesia. These patients were randomly assigned into two groups: a study group that included patients who received Tibrolin® postoperatively and a control group that did not. The predictor variable was whether to use SET or not. Pain measured by the pain numerical rating scale (NRS), facial swelling, and the degree of trismus were the outcome variables. The Arabic version of the Oral Health Impact P
... Show MoreThe aim of this study was to identify the effectiveness of using generative learning model in learning kinetic series on rings and horizontal bar in artistic gymnastics for men ,Also, the two groups were better in learning the two series of movements on the rings and horizontal bar . The experimental method was used to design two parallel groups with pretested and posttest .The sample included third graders at the College of Physical Education and Sports Sciences - University of Baghdad ,The third class (d) was chosen to represent the control group that applied the curriculum in the college, with (12) students per group. After conducting the tribal tests, the main experiment was carried out for (8) weeks at the rate of two units per week di
... Show MoreBrowse Iraqi academic journals and research papers
A specific, sensitive and simple method was used for the determination of: vitamin B9 (Folic acid) in pure and pharmaceutical formulations using continuous flow injection analysis. The method is based on formation of ion pair compound between folic acid and ammonium molybdate in an aqueous medium to obtain a gray precipitate complex, using homemade; Ayah-6SX1-ST-2D solar cell CFI Analyzer. Optimum parameters was studied to increase the sensitivity for developed method. The linear range for the calibration graph was 0.01-0.6 mMol.L-1 of vitamin B9 and LOD was 131.994 ng/sample with correlation coefficient ( r ) of 0.9810, RSD% was lower than 0.1%, (n=9) for the determination of vitamin B9 at concentration (0.07and 0.5) mMol.L-1 respectiv
... Show MoreA sensitive and accurate colorimetric method was developed for the determination of the Sitagliptin phosphate monohydrate, here and after will be named Sitagliptin, in its pure and pharmaceutical form. The suggested approach is based on boosting the sensitivity of the traditional spectrometric methods by derivatizing Sitagliptin into a colored product that absorbs the visible spectrum at 573 nm. The proposed method has effectively improved the sensitivity and the limit of detection for the analysis of Sitagliptin. A linear calibration curve was obtained over the concentration range of 0.1-10 μg/ml with a correlation coefficient of 0.9983. The calculated recovery was within the range of 98.98–100.11%. While the limit of detection LOD and
... Show MoreObjective(s): To determine the impact of the Electronic Health Information Systems upon medical, medical backing and administrative business fields in Al-Kindy Teaching Hospital and to identify the relationship between such impact and their demographic characteristics of years of employment, place of work, and education. Methodology: A descriptive analytical design is employed through the period of April 25th 2016 to May 28th 2016. A purposive "non- probability" sample of (50) subject is selected. The sample is comprised of (25) medical and medical backing staff and (25) administrative staff who are all
A simple , sensitive and accurate spectrophotometric method for the trace determination of bismuth (III) has been developed .This method is based on the reaction of bismuth (III) with arsenazo(III) in acid solution (pH=1.9) to form a blue water soluble complex which exhibits maximum absorption at 612nm .Beer's law is obeyed over the concentration range of 2-85 ?g bismuth (III) in a final volume of 20 mL( i.e. 0.1 – 4.25?g.mL-1) with a correlation coefficient of (0.9981) and molar absorptivity 1.9×104 L.mol-1.cm-1 . The limit of detection (LOD) and the limit of quantification (LOQ) are 0.0633 and 0.0847 ?g.mL-1 , respectively . Under optimum conditions,the stoichiometry of the reaction between bismuth (III) and arsenazo(III) r
... Show MoreThe comparative method plays a major role in Maupassant’s novel (A woman’s Life).This is due to a good theme choice and smooth writing style characterized by simplicity, spontaneity and brevity.
The author uses the comparative method in the introduction of his novel where he compares the monastery’s closed world to the open world of the countryside of La Normandie, which represents the dream life of the heroine Jeanne.
The present paper is an attempt to answer the question regarding the importance of applying the comparative method in the novel (A Woman’s Life) by Maupassant. The paper stresses the fact that the novelist employs the comparative method in his book for certain features .One of these features is the
... Show More