Background: Cystinosis is a rare autosomal recessive lysosomal storage disease with high morbidity and mortality. It is caused by mutations in the CTNS gene that encodes the cystine transporter, cystinosin, which leads to lysosomal cystine accumulation. It is the major cause of inherited Fanconi syndrome, and should be suspected in young children with failure to thrive and signs of renal proximal tubular damage. The diagnosis can be missed in infants, because not all signs of renal Fanconi syndrome are present during the first months of life. Elevated white blood cell cystine content is the cornerstone of the diagnosis. Since chitotriosidase (CHIT1 or chitinase-1) is mainly produced by activated macrophages both in normal and inflammatory conditions which suggest that cystinosis should be included within the differential diagnosis of disorders associated with increased plasma chitotriosidase activity. This study is aimed to estimate serum chitotriosidase level, as a screening marker and therapeutic monitor for cystinosis disease in Iraqi children with cystinosis.
Subjects and Methods: The present study is a case-control study that included samples of 30 children with nephropathic cystinosis, compared to 25 healthy control children from those attending at The Genetic Rare Diseases Center / AL-Emamain AL-Kadhimain Teaching Hospital, Baghdad-Iraq.
Results: Our results reported that cystinotic children had a marked elevation of serum chitotriosidase activity, compared to age-matched healthy children, besides a significant associated with leukocyte-cystine content for cystinotic patients.
CHT1 as a Novel Biomarker
Conclusion: Estimation of serum chitotriosidase activity might aid in monitoring the therapeutic benefits of cysteamine therapy, as well as the prognosis of the disease when WBC cystine assessment is not available.
Key Words: Cystinosis, Cysteamine, Chitotriosidase.

This study uses an environmentally friendly and low-cost synthesis method to manufacture zinc oxide nanoparticles (ZnO NPs) by using zinc sulfate. Eucalyptus leaf extract is an effective chelating and capping agent for synthesizing ZnO NPs. The structure, morphology, thermal behavior, chemical composition, and optical properties of ZnO nanoparticles were studied utilizing FT-IR, FE-SEM, EDAX, AFM, and Zeta potential analysis. The FE-SEM pictures confirmed that the ZnO NPs with a size range of (22-37) nm were crystalline and spherical. Two methods were used to prepare ZnO NPs. The first method involved calcining the resulting ZnO NPs, while the second method did not. The prepared ZnO NPs were used as adsorbents for removing acid black 210
... Show MoreA taxonomic keys was established of book and bark lice Order Psocoptera to isolated insects in Iraq from different localities of Baghdad and Babylon provinces. Thirteen species belong to eight genera and five families have been studied and described in details, these species were recorded for the first time in Iraq. These species are: Belaphopsocus badonneli New, 1971; Belaphotroctes oculeris Bodonnel, 1973; Embodopsocosis newi Bodonnel, 1973; Epipsocus stigamaticus Mockeord, 1991; Lepinotus huoni Schmidt and New, 2008; Liposcelies decolor Peramane 1925 Liposcelies paeta Pearman 1942 Liposclies bostrychphila Badonnel 1931; Liposclies brunnea Mostchulsky 1852; Liposclies entoophila Enderlein 1907; Neopsocopsis minuscule Li 2002 ;
... Show MoreEach Intensity Modulated Radiation Therapy (IMRT) plan needs to be tested and verified before any treatment to check its quality. Octavius 4D-1500 phantom detector is a modern and qualified device for quality assurance procedure. This study aims to compare the common dosimetric criteria 3%/3 mm with 2%/2 mm for H&N plans for the IMRT technique. Twenty-five patients with head and neck (H&N) tumor were with 6MV x-ray photon beam using Monaco 5.1 treatment planning software and exported to Elekta synergy linear accelerator then tested for pretreatment verification study using Octavius 4D-1500 phantom detector. The difference between planned and measured dose were assessed by using local and global gamma index (GI) analysis method at
... Show MoreThe aim of this article is to solve the Volterra-Fredholm integro-differential equations of fractional order numerically by using the shifted Jacobi polynomial collocation method. The Jacobi polynomial and collocation method properties are presented. This technique is used to convert the problem into the solution of linear algebraic equations. The fractional derivatives are considered in the Caputo sense. Numerical examples are given to show the accuracy and reliability of the proposed technique.
This study presents the debonding propagation in single NiTi wire shape memory alloy into linear low-density polyethylene matrix composite the study of using the pull-out test. The aim of this study is to investigate the pull-out tests to check the interfacial strength of the polymer composite in two cases, with activation NiTinol wire and without activation. In this study, shape memory alloy NiTinol wire 2 mm diameter and linear fully annealed straight shape were used. The study involved experimental and finite element analysis and eventually comparison between them. This pull-out test is considered a substantial test because its results have a relation with behavior of smart composite materials. The pull-out test was carried out by a u
... Show MoreThis paper compare the accurecy of HF propagation prediction programs for HF circuits links between Iraq and different points world wide during August 2018 when solar cycle 24 (start 2009 end 2020) is at minimun activity and also find out the best communication mode used. The prediction programs like Voice of America Coverage Analysis Program (VOACAP) and ITU Recommendation RS 533 (REC533 ) had been used to generat HF circuit link parameters like Maximum Usable Frequency ( MUF) and Frequency of Transsmision (FOT) .Depending on the predicted parameters (data) , real radio contacts had been done using a radio transceiver from Icom model IC 7100 with 100W RF
... Show MoreA simple, rapid, sensitive and inexpensive approach is described in this work based on a combination of solid‐phase extraction of 8‐hydroxyquinoline (8HQ), for speciation and preconcentration of Cr(III) and Cr(VI) in river water, and the direct determination of these species using a flow injection system with chemiluminescence detection (FI–CL) and a 4‐diethylamino phenyl hydrazine (DEAPH)–hydrogen peroxide system. At different pH, the two forms of chromium [Cr(III) and Cr(VI)] have different exchange capacities for 8HQ, therefore two columns were constructed; the pH of column 1 was adjusted to pH 3 for retaining Cr(III) and column 2 was adjusted to pH 1 for retaining of Cr(VI). The sorbe