Preferred Language
Articles
/
bhie-JYBVTCNdQwCiJSx
Transcatheter balloon valvuloplasty for children with severe pulmonary valve stenosis: A single-center experience
...Show More Authors
Abstract<p> <bold>Objectives</bold>: this study aim to assess the effectiveness of the Transcatheter balloon valvoplasty (BVP) of severe Pulmonary stenosis (PS) and identify possible complications and predictors for the outcome.</p><p> <bold>Methods</bold>: A retrospective study was conducted at the Iraqi Center of Cardiac Diseases for a 2-year duration in the period from 2021 to the end of 2023; the patients with confirmed severe PS of both genders within the age equal to or less than 18 years were included. For every patient included in the present study, the following data were collected: Demographic data, Echocardiographic criteria Hemodynamic parameters pre- and post-Cath, Catheterization data including the site of vascular access, need for general anesthesia and tracheal intubation, number and size of balloons used, any complications recorded at therapeutic session obtained from Cath lab archive.</p><p> <bold>Results</bold>: After BVP, the pressure gradient across the valve reduced from 105±25 to 32 ± 11(mmHg), (P<0.001); the systemic right ventricular pressure dropped from 120 ± 25 (mmHg) before to 54 ± 14 (mmHg) after (P<0.001). A significant increase in the systemic pulmonary pressure from 18 ± 4 (mmHg) before to 22 ± 3(mmHg) (P<0.001). Tricuspid valve regurgitation (TVR) reduced significantly (P=0.002). Pulmonary incompetence (PI) changed from mild to moderate and severe in 12 cases (P=0.001). Nine cases (20%) developed complications; 6 (13.3%) supraventricular tachycardia and 3 (6.7%) Cardiac arrest and cardiopulmonary resuscitation. The strongest association to complication occur-rence was pulmonary valve annulus size with r= 0.417 and TVR and PI severity with P=0.001, 0.017, respectively.</p><p> <bold>Conclusion</bold>: Transcatheter BVP is an effective procedure for severe PS cases but carry a risk of cardiac complications. The complication rate was linked to the patients’ demographical characteristics and PV annulus size and degree of TVR and PI severity.</p>
Scopus Crossref
View Publication
Publication Date
Wed Jul 10 2019
Journal Name
Proceedings Of The Institution Of Mechanical Engineers, Part H: Journal Of Engineering In Medicine
The speed, reflection and intensity of waves propagating in flexible tubes with aneurysm and stenosis: Experimental investigation
...Show More Authors

A localized stenosis or aneurysm is a discontinuity that presents the pulse wave produced by the contracting heart with a reflection site. However, neither wave speed ( c) in these discontinuities nor the size of reflection in relation to the size of the discontinuity has been adequately studied before. Therefore, the aim of this work is to study the propagation of waves traversing flexible tubes in the presence of aneurysm and stenosis in vitro. We manufactured different sized four stenosis and four aneurysm silicone sections, connected one at a time to a flexible ‘mother’ tube, at the inlet of which a single semi-sinusoidal wave was generated. Pressure and velocity were measured simultaneously 25 cm downstream the inlet of th

... Show More
View Publication Preview PDF
Scopus (10)
Crossref (9)
Scopus Clarivate Crossref
Publication Date
Mon Dec 04 2017
Journal Name
Al-qadisiyah Journal For Administrative And Economic Sciences
Survival Function Estimating of Single age Groups for Generalized Gamma Distribution with Simulation.
...Show More Authors

The analysis of survival and reliability considered of topics and methods of vital statistics at the present time because of their importance in the various demographical, medical, industrial and engineering fields. This research focused generate random data for samples from the probability distribution Generalized Gamma: GG, known as: "Inverse Transformation" Method: ITM, which includes the distribution cycle integration function incomplete Gamma integration making it more difficult classical estimation so will be the need to illustration to the method of numerical approximation and then appreciation of the function of survival function. It was estimated survival function by simulation the way "Monte Carlo". The Entropy method used for the

... Show More
Preview PDF
Publication Date
Wed Dec 29 2021
Journal Name
Al-khwarizmi Engineering Journal
Analysis of Magnetorheological Normally Close Directional Control Valve
...Show More Authors

This valve is intended for use in valves for steering movement, using the qualities of the Magneto-rheological (MR) fluid to regulate the fluid, direct contact without the utilization of moving parts like a spool, a connection between electric flux, and fluid power was made, The simulation was done to employ the" finite element method of magnetism (FEMM)" to arrive at the best design. This software is used for magnetic resonance valve finite element analysis. The valve's best performance was obtained by using a closed directional control valve in the normal state normally closed (NC) MR valve, with simulation results revealing the optimum magnetic flux density in the absence of a current and the shedding condition, as well as the optimum pr

... Show More
Preview PDF
Publication Date
Tue Nov 01 2011
Journal Name
Advanced Materials Research
Experimental Test of Magneto-Rheological Directional Control Valve
...Show More Authors

Directional control valve is the main part in hydraulic system which has complex construction, such as moving spool to control the direction of actuator for required speed. Utilizing MR fluid properties, direct interface can be realized between magnetic field and fluid power without the need for moving parts like spool in directional control valves. This paper dedicates the experimental test of four ways, three position MR directional control valve. The experimental methods were done by connecting the MR directional control valve with hydraulic actuators. The experiment was conducted to show the principle work of the valve functionally and performance test for valve was done. The valve works proportionally to control the direction a

... Show More
Scopus (5)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Sun Mar 25 2018
Journal Name
Biomedical And Pharmacology Journal
Anti CD20 Monoclonal Antibody (Rituximab) as a Rescue Treatment in Severe and Refractory SLE
...Show More Authors

Systemic lupus erythematosus (SLE) is an autoimmune disease with polymorphic expression. B cells have an essential contribution in immune system activation via the production of different cytokines and functioning as potent antigen-presenting cells. Therefore, a drug that particularly targets B cells may represent an ideal therapeutic approach for SLE. Rituximab (RTX), an anti-CD20 monoclonal antibody causing transient B-cell depletion, has been used to manage SLE. This study aims to assess Rituximab effects on lupus nephritis (LN) patients when added to conventional immunosuppressants. Twenty four patients, 15-32 years old, with class III/IV/V LN were involved in this study. All were on steroids before lupus nephritis occurrence. They were

... Show More
Publication Date
Sun Mar 25 2018
Journal Name
Biomedical And Pharmacology Journal
Anti CD20 Monoclonal Antibody (Rituximab) as a Rescue Treatment in Severe and Refractory SLE
...Show More Authors

Systemic lupus erythematosus (SLE) is an autoimmune disease with polymorphic expression. B cells have an essential contribution in immune system activation via the production of different cytokines and functioning as potent antigen-presenting cells. Therefore, a drug that particularly targets B cells may represent an ideal therapeutic approach for SLE. Rituximab (RTX), an anti-CD20 monoclonal antibody causing transient B-cell depletion, has been used to manage SLE. This study aims to assess Rituximab effects on lupus nephritis (LN) patients when added to conventional immunosuppressants. Twenty four patients, 15-32 years old, with class III/IV/V LN were involved in this study. All were on steroids before lupus nephritis occurrence. They were

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (2)
Scopus Crossref
Publication Date
Fri Jul 07 2023
Journal Name
Journal Of Obstetrics, Gynecology And Cancer Research
Evaluation of Maternal and Fetal Complications in Pregnant Women with Polycystic Ovary Syndrome (PCOS) with Severe and Mild Phenotype
...Show More Authors

An essential issue in obstetrics is the prevalence of maternal and fetal complications in pregnant women with polycystic ovary syndrome (PCOS). The purpose of the present study was to investigate the prevalence of pregnancy complications among various phenotypes of pregnant women with PCOS.

View Publication
Crossref
Publication Date
Sun Mar 30 2003
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Improvement of CIATIM-201 Grease Properties for Use under Severe Conditions using Suitable Additives
...Show More Authors

View Publication Preview PDF
Publication Date
Wed Mar 10 2021
Journal Name
Baghdad Science Journal
Account the expected values ??for a single particle to a group of atoms and ions
...Show More Authors

Technique was used to retail for analyzing atom beryllium ion cathode of an atom lithium to six pairs of functions wave which two ?????? and the rest of the casing moderation and to analyze atom lithium ion Mob atom beryllium to three pairs of functions wave pair of casing and the rest of the casing moderation using function wave Hartree Fock and each casing email wascalculate expected values ??....

View Publication Preview PDF
Publication Date
Wed May 11 2022
Journal Name
Journal Of Economics And Administrative Sciences
Comparing Some Methods For A single Imputed A missing Observation In Estimating Nonparametric Regression Function
...Show More Authors

In this paper, we will study non parametric model when the response variable have missing data (non response) in observations it under missing mechanisms MCAR, then we suggest Kernel-Based Non-Parametric Single-Imputation instead of missing value and compare it with Nearest Neighbor Imputation by using the simulation about some difference models and with difference cases as the sample size, variance and rate of missing data.      

View Publication Preview PDF
Crossref