The experiment aimed to Manufacture a device for checking the nozzles and testing its efficiency and to study the effect of research factors on the studied traits. The device was manufactured locally through using materials available in the Iraqi market. The system is Both Hydraulic and electronic (ISO 5682-1)1 relay on sensors technology and the test platform was built and designed on a movable trolly at the department of Agricultural Machines and Equipment / College of Agricultural Science / University of Baghdad. The design includes the use of mechanical water pump and electrical AC water pump. The design includes a nozzle holder that can accommodate three nozzles per test. The design also consists of spreading wings and stationary wing that can accommodate 50 vessels and 50 ultra-sonic sensors. All that is controlled by a main control unit which consists of three branch modules (each one of them is responsible to collect and analyze data from several sensors on each of the wings. The idea behind the design is to merge between actual spraying and the use of electronic sensors to analyze the size of the sprayed liquid in each of the vessels, the concept of the design is based upon Volumetric distribution of the liquid. The concept of the device was based on using ultra sonic sensors to measure the volumetric distribution of liquids. The experiment aimed to determine the effects of these factors on flow rate, spraying angle, sprayed area, spraying swath, volumetric distribution (CV), and symmetry. The experiment was conducted at the college of Agricultural science, Baghdad University. The results showed that the spraying pressure had a non-significant effect on flow rate. However, increasing the pressure from 3.0 to 5.0 and then to 7.0 bar resulted in flow rates of 1.314, 1.286, and 1.36 l/m, respectively. The status of the nozzle (new or worn) did not significantly affect the flow rate, with new nozzles registering a slightly higher flow rate of 1.327 l/m compared to worn nozzles (1.312 l/m). On the other hand, the type of nozzle had a significant impact on flow rate, with plastic, brass, and steel nozzles registering flow rates of 1.243, 1.422, and 1.29 l/m, respectively. Regarding the spraying angle, the results indicated that the spraying pressure had a significant effect. Increasing the pressure from 3.0 to 5.0 and then to 7.0 bar resulted in spraying angles of 132, 132, and 136 degrees, respectively. The nozzle status significantly affected the spraying angle, with worn nozzles resulting in a higher angle of 137 degrees compared to new nozzles (130 degrees). However, the type of nozzle did not significantly affect the spraying angle. For the sprayed area, the spraying pressure had a significant effect, with higher pressures resulting in larger sprayed areas. Worn nozzles also significantly increased the sprayed area compared to new nozzles. The type of nozzle had a significant impact on the sprayed area, with plastic, brass, and steel nozzles resulting in areas of 70.4, 80.44, and 89.16 cm2, respectively. The experiment proved that nozzles must be tested periodically, otherwise they start to perform beyond the parameters they were designed to perform with.
Diesel engine oil was subjected to thermal oxidization (TO) for six periods of time (0 h, 24 h, 48 h, 72 h, 96 h, and 120 h) and was subsequently characterized by terahertz time domain spectroscopy (THz-TDS). The THz refractive index generally increased with oxidation time. The measurement method illustrated the potential of THz-TDS when a fixed setup with a single cuvette is used. A future miniaturized setup installed in an engine would be an example of a fixed setup. For the refractive index, there were highly significant differences among the oxidation times across most of the 0.3–1.7 THz range.
In this study, four different spectrophotometric methods were applied for determination of cimetidine and erythromycin ethylsuccinate drugs in pure form and in their pharmaceutical preparations. The suggested methods are simple, sensitive, accurate, not time consuming and inexpensive. The results showed the following: The first method: Based on the formation of ion pair complex of each drug with bromothymol blue (BTB) as a chromogenic reagent. The formed complexes were extracted with chloroform and their absorbance values were measured at 427.5 nm for cimetidine and 416.5nm for erythromycin ethylsuccinate; against their reagents blanks. Two different methods, univariate method and multivariate method, were used to obtain the optimum condit
... Show MoreDielectric barrier discharges (DBD) can be described as the presence of contact with the discharge of one or more insulating layers located between two cylindrical or flat electrodes connected to an AC/pulse dc power supply. In this work, the properties of the plasma generated by dielectric barrier discharge (DBD) system without and with a glass insulator were studied. The plasma was generated at a constant voltage of 4 kV and fixed distance between the electrodes of 5 mm, and with a variable flow rate of argon gas (0.5, 1, 1.5, 2 and 2.5) L/min. The emission spectra of the DBD plasmas at different flow rates of argon gas have been recorded. Boltzmann plot method was used to calculate the plasma electron temperature (Te), and Stark broadeni
... Show MoreSensing insole systems are a promising technology for various applications in healthcare and sports. They can provide valuable information about the foot pressure distribution and gait patterns of different individuals. However, designing and implementing such systems poses several challenges, such as sensor selection, calibration, data processing, and interpretation. This paper proposes a sensing insole system that uses force-sensitive resistors (FSRs) to measure the pressure exerted by the foot on different regions of the insole. This system classifies four types of foot deformities: normal, flat, over-pronation, and excessive supination. The classification stage uses the differential values of pressure points as input for a feedforwar
... Show MoreAim: This abstract aims to highlight the critical nature of climate change as a pressing challenge facing humanity in the 21st century. It underscores the severe consequences it poses to essential facets of human existence, including water and energy resources, agricultural production, and the broader environmental systems. Method: The abstract primarily utilizes a descriptive approach to emphasize the impact of climate change on the Middle East, particularly the Arab region. It relies on a review of existing knowledge and data related to climate change and its effects on ecosystems and drought patterns. Results: The abstract outlines the direct and indirect repercussions of climate change on human life and the environment. It draws atten
... Show MoreRadioactive elements were identified in samples of imported coffee consumed in the province of Basra using gamma spectrometry SAM940TM. It is a scintillation detector of NaI(Tl) crystal and the dimensions of 2×2 inch. We have identified specific concentration As(Bq/kg) and annual effective dose D(Sv/y) for radioactive elements (_^40)K, (_^131)I, (_^134)Cs and (_^137)Cs. The estimated average effective dose for adults from coffee samples were found to be 0.037mSv/y, 88.434nSv/y, 46.909nSv/y, 27.212nSv/y for ((_^40)K,(_^131)I,(_^134)Cs,(_^137)Cs) respectively. The present results of the study revealed that the radioactivity was relatively low in the coffee and within the permissiblelimit.
This research aims to identify the nutritional status of the individual's relationship to malnutrition using anthropometric measurements such as weight, height and impact on the values ??of the blood study sample included 200 male and 200 female of the inhabitants of the cities of Baghdad and Baquba reviewers Central Mahtbrat
Background: The aim of this in vitro study was to evaluate and compare the microleakage between Vertise Flow T M composite material and other conventional (Filtek Z250, riva light cure and SDR) composite materials when restoring CII mesial box only cavity at gingival margin through die penetration test Materials and methods: Forty maxillary first premolars were prepared with class II box design only cavities. Samples were divided into four groups of ten teeth according to material used: group I (FiltekZ250 only). Group II (SDR+FiltekZ250). Group III (Vertise Flow +FiltekZ250). Group IV (Riva light cure+ FiltekZ250). After 24 hrs. immersion in 2% in methylene blue, samples were sectioned and micro leakage was estimated. Results: None of the
... Show More